Despite the rapid advancement of left ventricular assist devices (LVADs), adverse events leading to deaths have been frequently reported in patients implanted with LVADs, including bleeding, infection, thromboembolism, neurological dysfunction and hemolysis. Cannulation forms an important component with regards to thrombus formation in assisted patients by varying the intraventricular flow distribution in the left ventricle (LV). To investigate the correlation between LVAD cannula placement and potential for thrombus formation, detailed analysis of the intraventricular flow field was carried out in the present study using a two way fluid structure interaction (FSI), axisymmetric model of a passive LV incorporating an inflow cannula. Three different cannula placements were simulated, with device insertion near the LV apex, penetrating one-fourth and mid-way into the LV long axis. The risk of thrombus formation is assessed by analyzing the intraventricular vorticity distribution and its associated vortex intensity, amount of stagnation flow in the ventricle as well as the level of wall shear stress. Our results show that the one-fourth placement of the cannula into the LV achieves the best performance in reducing the risk of thrombus formation. Compared to cannula placement near the apex, higher vortex intensity is achieved at the one-fourth placement, thus increasing wash out of platelets at the ventricular wall. One-fourth LV penetration produced negligible stagnation flow region near the apical wall region, helping to reduce platelet deposition on the surface of the cannula and the ventricular wall.
引用
收藏
页数:14
相关论文
共 33 条
[1]   Flow-induced platelet activation and damage accumulation in a mechanical heart valve: Numerical studies [J].
Alemu, Yared ;
Bluestein, Danny .
ARTIFICIAL ORGANS, 2007, 31 (09) :677-688
[2]   AN IMPROVED LEFT-VENTRICULAR CANNULA FOR CHRONIC DYNAMIC BLOOD PUMP SUPPORT [J].
ANTAKI, JF ;
DENNIS, TJ ;
KONISHI, H ;
BROWN, ME ;
MAHER, TR ;
TOMCZAK, JP ;
KERRIGAN, JP ;
KORMOS, RL .
ARTIFICIAL ORGANS, 1995, 19 (07) :671-675
[3]   Model and influence of mitral valve opening during the left ventricular filling [J].
Baccani, B ;
Domenichini, F ;
Pedrizzetti, G .
JOURNAL OF BIOMECHANICS, 2003, 36 (03) :355-361
[4]  
Bachman TN, 2011, CARDIOVASC ENG TECHN, P1
[5]   A review of computational fluid dynamics analysis of blood pumps [J].
Behbahani, M. ;
Behr, M. ;
Hormes, M. ;
Steinseifer, U. ;
Arora, D. ;
Coronado, O. ;
Pasquali, M. .
EUROPEAN JOURNAL OF APPLIED MATHEMATICS, 2009, 20 :363-397
[6]   Fluid-structure coupled CFD simulation of the left ventricular flow during filling phase [J].
Cheng, YG ;
Oertel, H ;
Schenkel, T .
ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (05) :567-576
[7]   Novel ventricular apical cannula - In vitro evaluation using transparent, compliant ventricular casts [J].
Curtis, AS ;
Wu, ZJJ ;
Kormos, RL ;
Griffith, BP ;
Antaki, JF .
ASAIO JOURNAL, 1998, 44 (05) :M691-M695
[8]  
Dobre AA, 2010, INF TECHN APPL BIOM, P1
[9]   Shear properties of passive ventricular myocardium [J].
Dokos, S ;
Smaill, BH ;
Young, AA ;
LeGrice, IJ .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2002, 283 (06) :H2650-H2659
[10]   Bleeding and Thrombosis in Patients With Continuous-Flow Ventricular Assist Devices [J].
Eckman, Peter M. ;
John, Ranjit .
CIRCULATION, 2012, 125 (24) :3038-3047