Indirect competitive immunoassay for the detection of fungicide Thiabendazole in whole orange samples by Surface Plasmon Resonance

被引:40
作者
Estevez, M. -Carmen [1 ,2 ]
Belenguer, Jose [3 ]
Gomez-Montes, Silvia [1 ,2 ]
Miralles, Javier [3 ]
Escuela, Alfonso M. [4 ]
Montoya, Angel [5 ]
Lechuga, Laura M. [1 ,2 ]
机构
[1] Res Ctr Nanosci & Nanotechnol CIN2 CSIC, Nanobiosensors & Bioanalyt Applicat Grp, Barcelona 08193, Spain
[2] CIBER BBN, Barcelona 08193, Spain
[3] Ainia Ctr Tecnol, E-46980 Valencia, Spain
[4] Univ Las Palmas, Inst Appl Microelect, Las Palmas Gran Canaria, Spain
[5] Univ Politecn Valencia, Immunotechnol Grp, Inst Interuniv Invest Bioingn & Tecnol Orientada, Valencia 46022, Spain
关键词
NATURAL-WATER SAMPLES; PESTICIDE-RESIDUES; POSTHARVEST FUNGICIDES; ENVIRONMENTAL-ANALYSIS; LIQUID-CHROMATOGRAPHY; ANTIBODY-PRODUCTION; FRUIT JUICES; IMMUNOSENSOR; VEGETABLES; GAS;
D O I
10.1039/c2an36094b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive and specific SPR-based competitive immunoassay for the detection of Thiabendazole (TBZ) has been developed. An indirect format where a TBZ-protein conjugate is immobilized onto gold surfaces has been selected. Under the optimal conditions, a LOD of 0.67 nM (0.13 mu g L-1) and an IC50 of 3.2 nM (0.64 mu g L-1) have been achieved which are comparable to the values obtained by conventional ELISA. Analysis of real samples has been attempted by first evaluating the influence of complex matrix samples coming from whole oranges and secondly measuring samples containing TBZ previously evaluated by chromatographic methods. A methanolic extraction procedure followed by a simple dilution in assay buffer has proven to be sufficient to measure orange samples using the developed immunoassay with an excellent recovery percentage. The sensitivity and the feasibility of measuring whole orange samples demonstrate the effectiveness and robustness of the SPR biosensor, which can be useful for the determination of TBZ in food at concentrations below the Maximum Residue Levels (MRLs) established by the European legislation.
引用
收藏
页码:5659 / 5665
页数:7
相关论文
共 35 条
[31]   Analysis of post-harvest fungicides by micellar electrokinetic chromatography [J].
Rodríguez, R ;
Picó, Y ;
Font, G ;
Mañes, J .
JOURNAL OF CHROMATOGRAPHY A, 2001, 924 (1-2) :387-396
[32]   Biosensors as useful tools for environmental analysis and monitoring [J].
Rodriguez-Mozaz, Sara ;
Lopez de Alda, Maria J. ;
Barcelo, Damia .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (04) :1025-1041
[33]   Immunosensors for pesticide analysis: Antibody production and sensor development [J].
Suri, CR ;
Raje, M ;
Varshney, GC .
CRITICAL REVIEWS IN BIOTECHNOLOGY, 2002, 22 (01) :15-32
[34]   Determination of pesticide residues in fruit and vegetables [J].
Torres, CM ;
Pico, Y ;
Manes, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 754 (1-2) :301-331
[35]  
Tuan SJ, 2009, J FOOD DRUG ANAL, V17, P163