A reversed-phase high performance liquid chromatography coupled with resonance Rayleigh scattering detection for the determination of four tetracycline antibiotics

被引:53
作者
Wang, Li-Feng [1 ]
Peng, Jing-Dong [1 ]
Liu, Li-Min [1 ]
机构
[1] Southwest Univ, Sch Chem & Chem Engn, Chongqing 400715, Peoples R China
关键词
Reversed-phase high performance liquid chromatography; Resonance Rayleigh scattering; Tetracycline antibiotics;
D O I
10.1016/j.aca.2008.09.066
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new reversed-phase high performance liquid chromatography with resonance Rayleigh scattering detection (HPLC-RRS) was developed for simultaneous separation and determination of four tetracycline antibiotics (TCs). A good chromatographic separation among the compounds was achieved using a Synergi Fusion-RP column (150 mm x 4.6 mm; 4 mu m) and a mobile phase consisting of methanol-acetonitrile-oxalic acid (5 mM) at the flow rate of 0.8 mL min(-1). Column temperature was 30 degrees C. The RRS signal was detected at lambda(ex) = lambda(em) = 370 nm. The recoveries of sample added standard ranged from 95.3% to 103.5%, and the relative standard deviation was below 2.79%. A detection limit of 2.12-5.12 mu g mL(-1) was reached and a linear range was found between peak height and concentration in the range of 10.36-518.0 mu g mL(-1) for oxytetracycline (OTC), 12.11-605.5 mu g mL(-1) for tetracycline (TC), 11.79-589.5 mu g mL(-1) for chlortetracycline (CTC) and 10.32-516.0 mu g mL(-1), for doxycycline (DC). The linear regression coefficients were all above 0.999. The method has been applied successfully to the determination of OTC, TC, CTC, DC in pharmaceutical formulations and in honey. The method was simple, rapid and showed a better linear relation and high repeatability (C) 2008 Elsevier B.V All rights reserved.
引用
收藏
页码:101 / 106
页数:6
相关论文
共 29 条
[21]   FLOW-INJECTION DETECTION OF TETRACYCLINES BY ELECTROCATALYTIC OXIDATION AT A NICKEL-MODIFIED GLASSY-CARBON ELECTRODE [J].
OUNGPIPAT, W ;
SOUTHWELLKEELY, P ;
ALEXANDER, PW .
ANALYST, 1995, 120 (05) :1559-1565
[22]   COPPER CARBONATE AS A SOLID-BED REACTOR FOR SPECTROPHOTOMETRIC DETERMINATION OF DOXYCYCLINE AND OXYTETRACYCLINE IN AN UNSEGMENTED CONTINUOUS-FLOW ASSEMBLY [J].
PAZ, JLL ;
CALATAYUD, JM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (11-12) :1093-1098
[23]   Resonance Rayleigh scattering spectrum for the chelate of lanthanum(III) with sodium tanshinon IIA silate and its analytical application [J].
Peng Jingdong ;
Liu Shaopu ;
Liu Zhongfang ;
Shi Yan .
SCIENCE IN CHINA SERIES B-CHEMISTRY, 2006, 49 (05) :423-429
[24]   Simultaneous determination of fluoroquinolones and tetracyclines in chicken muscle using HPLC with fluorescence detection [J].
Schneider, Marilyn J. ;
Braden, Susan E. ;
Reyes-Herrera, Ixchel ;
Donoghue, Dan J. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 846 (1-2) :8-13
[25]   Determination of impurities in tetracycline hydrochloride by nonaqueous capillary electrophoresis [J].
Tjornelund, J ;
Hansen, SH .
JOURNAL OF CHROMATOGRAPHY A, 1996, 737 (02) :291-300
[26]  
Wei XQ, 2006, ACTA CHIM SINICA, V64, P521
[27]   Resonance Rayleigh scattering method for the determination of tetracycline antibiotics with uranyl acetate and water blue [J].
Wei, XQ ;
Liu, ZF ;
Liu, SP .
ANALYTICAL BIOCHEMISTRY, 2005, 346 (02) :330-332
[28]  
[Yang Zhou 杨卓], 2004, [西南师范大学学报. 自然科学版, Journal of Southwest China Normal University. Natural Science], V29, P773
[29]  
1995, USP 23, V1510, P621