Virtual Monochromatic Reconstruction of Dual-Energy Unenhanced Head CT at 65-75 keV Maximizes Image Quality Compared with Conventional Polychromatic CT

被引:157
作者
Pomerantz, Stuart R. [1 ]
Kamalian, Shervin
Zhang, Da
Gupta, Rajiv
Rapalino, Otto
Sahani, Dushyant V.
Lev, Michael H.
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
关键词
COMPUTED-TOMOGRAPHY; NOISE; ARTIFACTS;
D O I
10.1148/radiol.12111604
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the virtual monochromatic imaging (VMI) energy levels that maximize brain parenchymal image quality in dual-energy unenhanced head computed tomography (CT) and to assess the improvement with this technique compared with conventional polychromatic scanning. Materials and Methods: Institutional review board approval was obtained with no informed consent required for this HIPAA-compliant retrospective analysis. Twenty-five consecutive unenhanced head CT scans were acquired with a 64-section dual-energy scanner with fast tube voltage switching (80-140 kVp). Scans were retrospectively reconstructed at VMI energy levels from 40 to 140 keV in 5-keV increments and were analyzed by using four quality indexes: gray matter (GM) signal-to-noise ratio (SNR), white matter (WM) SNR, GM-WM contrast-to-noise ratio (CNR), and posterior fossa artifact index (PFAI). Optimal mean values for each parameter were compared with those from 50 consecutive scans obtained with the same scanner in 120-kVp single-energy mode. Repeated-measures analysis of variance and Dunnett post hoc t test were then used to determine significance. Results: Maximal GM SNR, WM SNR, and GM-WM CNR values were observed at 65 keV, and minimal PFAI was observed at 75 keV. These values were significantly better than those of conventional polychromatic CT (P < .01); quality index improvement ratios (corrected for radiation dose) ranged from 17% to 50%. Conclusion: Virtual monochromatic reconstruction of dual-energy unenhanced head CT scans at 65-75 keV (optimal energy levels) maximizes image quality compared with scans obtained with conventional polychromatic CT. (C)RSNA, 2012
引用
收藏
页码:318 / 325
页数:8
相关论文
共 19 条
[1]   Thick-section reformatting of thinly collimated helical CT for reduction of skull base-related artifacts [J].
Alberico, RA ;
Loud, P ;
Pollina, J ;
Greco, W ;
Patel, M ;
Klufas, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (05) :1361-1366
[2]   COMPARISON OF NOISE AND DOSE IN CONVENTIONAL AND ENERGY SELECTIVE COMPUTED-TOMOGRAPHY [J].
ALVAREZ, R ;
SEPPI, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) :2853-2855
[3]   OPTIMAL PROCESSING OF COMPUTED TOMOGRAPHY IMAGES USING EXPERIMENTALLY MEASURED NOISE PROPERTIES [J].
ALVAREZ, RE ;
STONESTROM, JP .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (01) :77-84
[4]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[5]  
*AM COLL RAD, 2012, ACR PRACT GUID DIAGN, DOI DOI 10.1118/1.3551999
[6]  
American College of Radiology, 2012, P SPIE MED IM 2009 P
[7]  
Chandra N, 2011, MED RADIOL DIAGN IMA, P35, DOI 10.1007/174_2010_35
[8]   Single- and dual-energy CT with monochromatic synchrotron x-rays [J].
Dilmanian, FA ;
Wu, XY ;
Parsons, EC ;
Ren, B ;
Kress, J ;
Button, TM ;
Chapman, LD ;
Coderre, JA ;
Giron, F ;
Greenberg, D ;
Krus, DJ ;
Liang, Z ;
Marcovici, S ;
Petersen, MJ ;
Roque, CT ;
Shleifer, M ;
Slatkin, DN ;
Thomlinson, WC ;
Yamamoto, K ;
Zhong, Z .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (02) :371-387
[9]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[10]   Basic Principles and Postprocessing Techniques of Dual-Energy CT: Illustrated by Selected Congenital Abnormalities of the Thorax [J].
Godoy, Myrna C. B. ;
Naidich, David P. ;
Marchiori, Edson ;
Assadourian, Bernard ;
Leidecker, Christianne ;
Schmidt, Bernhard ;
Vlahos, Ioannis .
JOURNAL OF THORACIC IMAGING, 2009, 24 (02) :152-159