Tissue-engineered aneurysm models for in vitro assessment of neurovascular devices

被引:7
作者
Shen, Tiffany W. [1 ]
Puccini, Brandon [2 ]
Temnyk, Kristen [1 ]
Herting, Scott [1 ]
Cardinal, Kristen O'Halloran [1 ]
机构
[1] Cal Poly, Dept Biomed Engn, 1 Grand Ave, San Luis Obispo, CA 93407 USA
[2] Cal Poly, Dept Mech Engn, 1 Grand Ave, San Luis Obispo, CA 93407 USA
关键词
Intracranial aneurysm; In vitro techniques; Feasibility studies; Flow diverters; Tissue engineering; Biological assays; BLOOD-VESSEL MIMICS; SACCULAR ANEURYSMS; RABBIT; CREATION;
D O I
10.1007/s00234-019-02197-x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposePreclinical testing of neurovascular devices is crucial for successful device design and is commonly performed using in vivo organisms such as the rabbit elastase-induced aneurysm model; however, simple in vitro models may help further refine this testing paradigm. The purpose of the current work was to evaluate, and further develop, tissue-engineered blood vessel mimics (BVMs) as simple, early-stage models to assess neurovascular devices in vitro prior to animal or clinical use.MethodsThe first part of this work used standard straight-vessel BVMs to evaluate flow diverters at 1, 3, and 5 days post-deployment. The second part developed custom aneurysm-shaped scaffolds to create aneurysm BVMs. Aneurysm scaffolds were characterized based on overall dimensions and microstructural features and then used for cell deposition and vessel cultivation.ResultsIt was feasible to deploy flow diverters within standard BVMs and cellular linings could withstand and respond to implanted devices, with increasing cell coverage over time. This provided the motivation and foundation for the second phase of work, where methods were successfully developed to create saccular, fusiform, and blister aneurysm scaffolds using a wax molding process. Results demonstrated appropriate fiber morphology within different aneurysm shapes, consistent cell deposition, and successful cultivation of aneurysm BVMs.ConclusionIt is feasible to use tissue-engineered BVMs for assessing cellular responses to flow diverters, and to create custom aneurysm BVMs. This supports future use of these models for simple, early-stage in vitro testing of flow diverters and other neurovascular devices.
引用
收藏
页码:723 / 732
页数:10
相关论文
共 32 条
[1]   Creation of saccular aneurysms in the rabbit: A model suitable for testing endovascular devices [J].
Altes, TA ;
Cloft, HJ ;
Short, JG ;
DeGast, A ;
Do, HM ;
Helm, GA ;
Kallmes, DF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :349-354
[2]  
[Anonymous], 2012, WHAT YOU SHOULD KNOW
[3]   Difference in configuration of ruptured and unruptured intracranial aneurysms determined by biplanar digital subtraction angiography [J].
Beck, J ;
Rohde, S ;
el Beltagy, M ;
Zimmermann, M ;
Berkefeld, J ;
Seifert, V ;
Raabe, A .
ACTA NEUROCHIRURGICA, 2003, 145 (10) :861-865
[4]   A concentric three element radial scanning optical coherence tomography endoscope [J].
Bonnema, Garret T. ;
Cardinal, Kristen O. ;
Williams, Stuart K. ;
Barton, Jennifer K. .
JOURNAL OF BIOPHOTONICS, 2009, 2 (6-7) :353-356
[5]   Tissue-engineered vascular grafts as in vitro blood vessel mimics for the evaluation of endothelialization of intravascular devices [J].
Cardinal, Kristen O'Halloran ;
Bonnema, Garret T. ;
Hofer, Heidi ;
Barton, Jennifer Kehlet ;
Williams, Stuart K. .
TISSUE ENGINEERING, 2006, 12 (12) :3431-3438
[6]   Endovascular creation of an in vivo bifurcation aneurysm model in rabbits [J].
Cloft, HJ ;
Altes, TA ;
Marx, WF ;
Raible, RJ ;
Hudson, SB ;
Helm, GA ;
Mandell, JW ;
Jensen, ME ;
Dion, JE ;
Kallmes, DF .
RADIOLOGY, 1999, 213 (01) :223-228
[7]  
de Oliveira IA, 2012, NEUROSURGERY, V9, P10264, DOI [10.5772/50310, DOI 10.5772/50310]
[8]  
Ding YH, 2006, AM J NEURORADIOL, V27, P139
[9]   A review of size and location of ruptured intracranial aneurysms [J].
Forget, TR ;
Benitez, R ;
Vezneclaroglu, E ;
Sharan, A ;
Mitchell, W ;
Silva, M ;
Rosenwasser, RH .
NEUROSURGERY, 2001, 49 (06) :1322-1325
[10]  
Fujiwara NH, 2002, AM J NEURORADIOL, V23, P1137