Investigation of discharge coefficient for wind-driven naturally ventilated dairy barns

被引:39
作者
Yi, Qianying [1 ]
Zhang, Guoqiang [1 ]
Koenig, Marcel [2 ]
Janke, David [2 ]
Hempel, Sabrina [2 ]
Amon, Thomas [2 ,3 ]
机构
[1] Aarhus Univ, Dept Engn, Blichers Alle 20,POB 50, DK-8830 Tjele, Denmark
[2] Leibniz Inst Agr Engn & Bioecon ATB, Dept Engn Livestock Management, Max Eyth Allee 100, D-14469 Potsdam, Germany
[3] Freie Univ, Inst Anim Hyg & Environm Hlth, Dept Vet Med, Robert von Ostertag Str 7-13, Berlin, Germany
关键词
Ventilation rate; Orifice equation; Discharge coefficient; Large openings; Opening size; Wind tunnel tests; AIR CHANGE RATE; CARBON-DIOXIDE; FLOW; BUILDINGS; BALANCE; AMMONIA; RATES; EMISSIONS; OPENINGS;
D O I
10.1016/j.enbuild.2018.01.038
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It is important to estimate the ventilation rate of animal houses accurately for the purpose of reducing emissions and providing comfortable indoor climate. The orifice equation is widely applied for estimating the airflow rate of naturally ventilated dairy barns. However, to regard openings' discharge coefficient (C-d) as a constant maybe not true for large openings. To gain basic knowledge of the opening size effects on C-d values, experiments with a scaled model were carried out in a large boundary layer wind tunnel. Seven cases with different sidewall opening ratios, varying from 18.6% to 81.4%, were investigated under 8 m/s wind speed conditions. The airflow rates, C-d values of windward openings and airflow patterns were analysed. It was found that the C-d value was considerably dependent on the opening size and varied from 0.67 to 0.94 when the opening ratio increased from 18.6% to 62.7%. This is due to the assumptions of pure pressure-driven flow and uniform velocity distributions in the opening were not satisfied for large opening cases. Our study suggests that C-d should be regarded as a variable under different opening size conditions when using the orifice equation to determine the airflow rate of large openings. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:132 / 140
页数:9
相关论文
共 47 条
[11]   ADIABATIC ATMOSPHERIC BOUNDARY-LAYERS - REVIEW AND ANALYSIS OF DATA FROM PERIOD 1880-1972 [J].
COUNIHAN, J .
ATMOSPHERIC ENVIRONMENT, 1975, 9 (10) :871-905
[12]   Validation of ventilation rate measurement methods and the ammonia emission from naturally ventilated dairy and beef buildings in the United Kingdom [J].
Demmers, TGM ;
Phillips, VR ;
Short, LS ;
Burgess, LR ;
Hoxey, RP ;
Wathes, CM .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 2001, 79 (01) :107-116
[13]  
Etheridge D., 2012, Natural Ventilation of Buildings: Theory, Measurement and Design
[14]  
Etheridge DW., 1996, Building ventilation: theory and measurement
[15]   Computational analysis of wind driven natural ventilation in buildings [J].
Evola, G ;
Popov, V .
ENERGY AND BUILDINGS, 2006, 38 (05) :491-501
[16]  
Fiedler M., 2014, Proceedings. International Conference of Agricultural Engineering AgEng, P1
[17]   SPATIAL DISTRIBUTION OF AIR FLOW AND CO2 CONCENTRATION IN A NATURALLY VENTILATED DAIRY BUILDING [J].
Fiedler, Merike ;
Saha, Chayan K. ;
Ammon, Christian ;
Berg, Werner ;
Loebsin, Christiane ;
Sanftleben, Peter ;
Amon, Thomas .
ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2014, 13 (09) :2193-2200
[18]   Air velocity measurements using ultrasonic anemometers in the animal zone of a naturally ventilated dairy barn [J].
Fiedler, Merike ;
Berg, Werner ;
Ammon, Christian ;
Loebsin, Christiane ;
Sanftleben, Peter ;
Samer, Mohamed ;
von Bobrutzki, Kristina ;
Kiwan, Alaa ;
Saha, Chayan K. .
BIOSYSTEMS ENGINEERING, 2013, 116 (03) :276-285
[19]  
Furukawa J., 2000, P ANN M AIJ D, V2, P551
[20]   Characteristics of airflow from open windows [J].
Heiselberg, P ;
Svidt, K ;
Nielsen, PV .
BUILDING AND ENVIRONMENT, 2001, 36 (07) :859-869