Investigation of discharge coefficient for wind-driven naturally ventilated dairy barns

被引:39
作者
Yi, Qianying [1 ]
Zhang, Guoqiang [1 ]
Koenig, Marcel [2 ]
Janke, David [2 ]
Hempel, Sabrina [2 ]
Amon, Thomas [2 ,3 ]
机构
[1] Aarhus Univ, Dept Engn, Blichers Alle 20,POB 50, DK-8830 Tjele, Denmark
[2] Leibniz Inst Agr Engn & Bioecon ATB, Dept Engn Livestock Management, Max Eyth Allee 100, D-14469 Potsdam, Germany
[3] Freie Univ, Inst Anim Hyg & Environm Hlth, Dept Vet Med, Robert von Ostertag Str 7-13, Berlin, Germany
关键词
Ventilation rate; Orifice equation; Discharge coefficient; Large openings; Opening size; Wind tunnel tests; AIR CHANGE RATE; CARBON-DIOXIDE; FLOW; BUILDINGS; BALANCE; AMMONIA; RATES; EMISSIONS; OPENINGS;
D O I
10.1016/j.enbuild.2018.01.038
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It is important to estimate the ventilation rate of animal houses accurately for the purpose of reducing emissions and providing comfortable indoor climate. The orifice equation is widely applied for estimating the airflow rate of naturally ventilated dairy barns. However, to regard openings' discharge coefficient (C-d) as a constant maybe not true for large openings. To gain basic knowledge of the opening size effects on C-d values, experiments with a scaled model were carried out in a large boundary layer wind tunnel. Seven cases with different sidewall opening ratios, varying from 18.6% to 81.4%, were investigated under 8 m/s wind speed conditions. The airflow rates, C-d values of windward openings and airflow patterns were analysed. It was found that the C-d value was considerably dependent on the opening size and varied from 0.67 to 0.94 when the opening ratio increased from 18.6% to 62.7%. This is due to the assumptions of pure pressure-driven flow and uniform velocity distributions in the opening were not satisfied for large opening cases. Our study suggests that C-d should be regarded as a variable under different opening size conditions when using the orifice equation to determine the airflow rate of large openings. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:132 / 140
页数:9
相关论文
共 47 条
[1]  
[Anonymous], ROOMVENT
[2]  
[Anonymous], P ROOMV 2002 COP DEN
[3]  
[Anonymous], 2000, COMPUTATION MEASUREM
[4]  
[Anonymous], 2009, ASHRAE Handbook|Fundamentals
[5]  
ASME, 2004, FLOW MEAS PTC 19 5
[6]   Ventilation flow in pig houses measured and calculated by carbon dioxide, moisture and heat balance equations [J].
Blanes, V ;
Pedersen, S .
BIOSYSTEMS ENGINEERING, 2005, 92 (04) :483-493
[7]  
Bruce J. M, 1975, FARM BUILDING RES DE, V7, P1
[8]   NATURAL-CONVECTION THROUGH OPENINGS AND ITS APPLICATION TO CATTLE BUILDING VENTILATION [J].
BRUCE, JM .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1978, 23 (02) :151-167
[9]   External flow effects on the discharge coefficients of two types of ventilation opening [J].
Chiu, Y-H. ;
Etheridge, D. W. .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2007, 95 (04) :225-252
[10]  
Coanda H., 1932, PROCEDE PROPULSION F