Engineering method for estimating the reactions of transmission line conductors under downburst winds

被引:39
|
作者
Aboshosha, Haitham [1 ]
El Damatty, Ashraf [2 ]
机构
[1] Univ Western Ontario, Boundary Layer Wind Tunnel Lab, London, ON, Canada
[2] Univ Western Ontario, Civil & Environm Engn Dept, London, ON, Canada
关键词
Transmission lines; Conductors; High Intensity Winds (HIW); Downburst; Closed form; Practitioner engineers; LOADS; MICROBURST; BEHAVIOR; FAILURE; TOWER; MODEL;
D O I
10.1016/j.engstruct.2015.04.010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, a closed form solution to calculate the reactions of transmission line conductors subjected to downburst loads is derived. The derivation is conducted using a simplified multi-spanned conductorinsulator system, where the insulators to the right and to the left of the tower of interest are modeled using a combination of roller supports and linear springs. The considered system allows for the interaction between the spans without the need of solving a set.of non-linear equations to avoid the complexity. The closed form solution is derived to be applicable for downbursts with arbitrary size and location relative to the line. The solution is then focused on a critical downburst case that is previously recommended for the line design. Accuracy of the derived solution is assessed under both downbursts with arbitrary size and location and downbursts corresponding to the critical case. The assessment is carried out by comparing the conductor reactions obtained using the proposed solution with those from the Finite Element Analyses (FEAs). It is found that the predicted reactions by the proposed solution are in a very good agreement with those from the FEA in both the transverse and the longitudinal directions. For example, the highest differences for the critical case are found equal to 2% and 8% for the reactions in the transverse and the longitudinal directions, respectively. This indicates that the solution is reasonably accurate given the complexity of both the downburst wind field and the structure behavior of the conductor system. The proposed solution represents a practical and useful tool for practitioner engineers involved in the design of transmission lines, particularly under downburst winds. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:272 / 284
页数:13
相关论文
共 50 条
  • [21] Fragility modelling framework for transmission line towers under winds
    Cai, Yunzhu
    Xie, Qiang
    Xue, Songtao
    Hu, Liang
    Kareem, Ahsan
    ENGINEERING STRUCTURES, 2019, 191 : 686 - 697
  • [22] Nonlinear inelastic responses of transmission tower-line system under downburst wind
    Yang, S. C.
    Hong, H. P.
    ENGINEERING STRUCTURES, 2016, 123 : 490 - 500
  • [23] Study on Wind Vibration Response and Coupling Effect of Transmission Tower-Line System Under Downburst
    Zhong, Yongli
    Liu, Yichen
    Li, Shun
    Yan, Zhitao
    Liu, Xinpeng
    IEEE ACCESS, 2024, 12 : 100120 - 100133
  • [24] Study on Wind-Induced Response of Transmission Tower-Line System under Downburst Wind
    Fang, Zhiyuan
    Wang, Zhisong
    Zhu, Renyu
    Huang, Hanjie
    BUILDINGS, 2022, 12 (07)
  • [25] Extensible catenary approach in analyzing transmission line's conductors under downbursts
    Shehata, Ahmed
    El Damatty, Ashraf
    ENGINEERING STRUCTURES, 2021, 234
  • [26] A method for analyzing stability of tower-line system under strong winds
    He Bo
    Zhao Mingxi
    Feng Wentao
    Xiu Yaping
    Wang Yu
    Feng Lijun
    Qin Yongjian
    Wang Chukun
    ADVANCES IN ENGINEERING SOFTWARE, 2019, 127 : 1 - 7
  • [28] Cost estimating method of power engineering overhead line based on fuzzy analogy
    Yi, Tao
    Zhang, Yi
    Cui, Shanshan
    Energy Education Science and Technology Part A: Energy Science and Research, 2014, 32 (06): : 6571 - 6580
  • [29] CSA-Kapur Method to Determine Ice Load Amount on Electric Transmission Line Conductors
    Akbal, Bahadir
    Aydin, Musa
    PROCEEDINGS OF THE 2014 6TH INTERNATIONAL CONFERENCE ON ELECTRONICS, COMPUTERS AND ARTIFICIAL INTELLIGENCE (ECAI), 2014,
  • [30] METHOD FOR CALCULATING HIGH-FREQUENCY INTERFERENCE ON TRANSMISSION-LINE CONDUCTORS DURING CORONA
    ZAKHARIT.MK