Comparison of real-time three-dimensional echocardiography with cardiovascular magnetic resonance for left ventricular volumetric assessment in unselected patients

被引:25
|
作者
Miller, Christopher A. [1 ,2 ,3 ]
Pearce, Keith [1 ]
Jordan, Peter [1 ]
Argyle, Rachel [1 ]
Clark, David [4 ]
Stout, Martin [1 ]
Ray, Simon G. [1 ,2 ]
Schmitt, Matthias [1 ,3 ]
机构
[1] Univ S Manchester Hosp, Div Cardiol & Cardiothorac Surg, Manchester M23 9LT, Lancs, England
[2] Univ Manchester, Cardiovasc Res Grp, Manchester, Lancs, England
[3] Univ Manchester, Biomed Imaging Inst, Manchester, Lancs, England
[4] Wythenshawe CMR Unit, Manchester, Lancs, England
基金
美国国家卫生研究院;
关键词
Real time three-dimensional echocardiography; Cardiovascular magnetic resonance; Left ventricle; Image quality; Ejection fraction; MYOCARDIAL-INFARCTION; COMPUTED-TOMOGRAPHY; EJECTION FRACTION; BORDER DETECTION; SINGLE-BEAT; QUANTIFICATION; REPRODUCIBILITY; ACCURACY; CARDIOMYOPATHIES; QUANTITATION;
D O I
10.1093/ejechocard/jer248
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To compare left ventricular (LV) volume indices and the ejection fraction (EF) obtained using real-time three-dimensional echocardiography (RT3DE) and cardiovascular magnetic resonance (CMR) in unselected patients representative of 'real-world' clinical practice, and to determine the effect of RT3DE image quality on these parameters. Methods and results Sixty consecutive patients undergoing CMR underwent same day RT3DE. LV volume and EF measurements were made using both modalities and compared. All scans were independently analysed by a second observer to assess inter-observer variability, and 40% were re-analysed to assess intra-observer variability. RT3DE image quality was graded as good, adequate, and non-analysable. Thirteen (22%) patients had good RT3DE image quality, 29 (48%) had adequate image quality, and 18 (30%) had image quality precluding analysis. Body mass index and arrhythmia frequency were higher in patients with suboptimal image quality. RT3DE significantly underestimated end-diastolic volume (EDV) (-45 +/- 35 mL, P<0.001), end-systolic volume (ESV) (-11 +/- 24 mL, P=0.004), and EF (27 +/- 9%, P<0.001) compared with CMR although the degree of underestimation was substantially less when image quality was good. Eleven patients (18%) classified as having a normal EF by CMR had a reduced EF according to RT3DE, all but one of which had suboptimal image quality. Observer variability for RT3DE was higher than for CMR for all parameters, however, the difference was not significant when RT3DE image quality was good. Conclusions In contrast to previously published data from highly selected patient groups, 'real-world' RT3DE substantially underestimates LV volumes and EF. The degree of underestimation is related to image quality.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 50 条
  • [31] Two-Dimensional Color Doppler Echocardiography for Left Ventricular Stroke Volume Assessment: A Comparison Study with Three-Dimensional Echocardiography
    Da Silva, Cristina
    Pedro, Fatima
    Deister, Lizandra
    Sahlen, Anders
    Manouras, Aristomenis
    Shahgaldi, Kambiz
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (07): : 766 - 772
  • [32] Assessment of left atrial functional parameters using a novel dedicated analysis tool for real-time three-dimensional echocardiography: validation in comparison to magnetic resonance imaging
    Buechel, Ronny R.
    Sommer, Gregor
    Leibundgut, Gregor
    Rohner, Andreas
    Riede, Florian
    Kessel-Schaefer, Arnheid
    Kaufmann, Beat A.
    Zellweger, Michael J.
    Bremerich, Jens
    Handke, Michael
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (03) : 601 - 608
  • [33] Left ventricular volume and function in cynomolgus monkeys using real-time three-dimensional echocardiography
    Tsusaki, Hideshi
    Yonamine, Haruno
    Tamai, Asako
    Shimomoto, Mutsuko
    Kuwano, Koichi
    Iwao, Hiroshi
    Nagata, Ryoichi
    Kito, Go
    JOURNAL OF MEDICAL PRIMATOLOGY, 2007, 36 (01) : 39 - 46
  • [34] Value of assessment of tricuspid annulus: real-time three-dimensional echocardiography and magnetic resonance imaging
    Ashraf M. Anwar
    Osama I. I. Soliman
    Attila Nemes
    Robert-Jan M. van Geuns
    Marcel L. Geleijnse
    Folkert J. ten Cate
    The International Journal of Cardiovascular Imaging, 2007, 23 : 701 - 705
  • [35] Semi-automated quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography
    Hansegard, Joger
    Urheim, Stig
    Lunde, Ketil
    Malm, Siri
    Rabben, Stein Inge
    CARDIOVASCULAR ULTRASOUND, 2009, 7
  • [36] Real-time three-dimensional left ventricular contraction in patients with diastolic dysfunction
    Hatipoglu, Suzan
    Guler, Gamze Babur
    Kaya, Ozgur
    Kahveci, Gokhan
    Guler, Ekrem
    Eroglu, Elif
    Ozdemir, Nihal
    JOURNAL OF MEDICAL ULTRASONICS, 2016, 43 (03) : 373 - 380
  • [37] Quantitative assessment of left ventricular size and function in cardiac transplant recipients: Side-by-side comparison of real time two-dimensional echocardiography, contrast-enhanced two-dimensional echocardiography, three-dimensional echocardiography, and contrast-enhanced three-dimensional echocardiography as compared to magnetic resonance imaging
    Rodriguez-Manero, Moises
    Azcarate-Aguero, Pedro
    Kreidieh, Bahij
    Teresa Alvez, Maria
    Martinez-Monzonis, Amparo
    Diaz-Dorronsoro, Agnes
    Cid-Menendez, Adrian
    Ramon Gonzalez-Juanatey, Jose
    Barba-Cosials, Joaquin
    Rabago, Gregorio
    Bastarrika, Gorka
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (02): : 306 - 311
  • [38] Real-time Three-dimensional Echocardiographic Assessment of Left Ventricular Remodeling Index in Patients with Hypertensive Heart Disease and Coronary Artery Disease
    Chen, Ming
    Wang, Jing
    Xie, Mingxing
    Wang, Xinfang
    Lv, Qing
    Wang, Lei
    Li, Yan
    Fu, Manli
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2009, 29 (01) : 122 - 126
  • [39] Assessment of left atrial volume and function by real-time three-dimensional echocardiography
    Anwar, Ashraf M.
    Soliman, Osama I. I.
    Geleijnse, Marcel L.
    Nemes, Attila
    Vletter, Wim B.
    ten Cate, Folkert J.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 123 (02) : 155 - 161
  • [40] Comparison of Real-Time Three-Dimensional Speckle Tracking to Magnetic Resonance Imaging in Patients With Coronary Heart Disease
    Hayat, Delphine
    Kloeckner, Martin
    Nahum, Julien
    Ecochard-Dugelay, Emmanuelle
    Dubois-Rande, Jean-Luc
    Jean-Francois, Deux
    Gueret, Pascal
    Lim, Pascal
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (02) : 180 - 186