Replacement of the knee meniscus by a porous polymer implant - A study in dogs

被引:91
作者
Tienen, TG
Heijkants, RGJC
de Groot, JH
Pennings, AJ
Schouten, AJ
Veth, RPH
Buma, P
机构
[1] Univ Nijmegen, Med Ctr, Orthopaed Res Lab, Dept Orthopaed, NL-6500 HB Nijmegen, Netherlands
[2] Univ Groningen, Dept Polymer Chem, Groningen, Netherlands
关键词
meniscus; animal study; prosthesis; polymer;
D O I
10.1177/0363546505280905
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Meniscectomy will lead to articular cartilage degeneration in the long term. Therefore, the authors developed an implant to replace the native meniscus. Hypothesis: The porous polymer meniscus implant develops into a neomeniscus and protects the cartilage from degeneration. Study Design: Controlled laboratory study. Methods: In a dog model, a porous polymer scaffold with optimal properties for tissue infiltration and regeneration of a neomeniscus was implanted and compared with total meniscectomy. The tissue infiltration and redifferentiation in the scaffold, the stiffness of the scaffold, and the articular cartilage degeneration were evaluated. Results: Three months after implantation, the implant was completely filled with fibrovascular tissue. After 6 months, the central areas of the implant contained cartilage-like tissue with abundant collagen type II and proteoglycans in their matrix. The foreign-body reaction remained limited to a few giant cells in the implant. The compression modulus of the implant-tissue construct still differed significantly from that of the native meniscus, even at 6 months. Cartilage degeneration was observed both in the meniscectomy group and in the implant group. Conclusion: The improved properties of these polymer implants resulted in a faster tissue infiltration and in phenotypical differentiation into tissue resembling that of the native meniscus. However, the material characteristics of the implant need to be improved to prevent degeneration of the articular cartilage. Clinical Relevance: The porous polymer implant developed into a polymer-tissue construct that resembled the native meniscus, and with improved gliding characteristics, this prosthesis might be a promising implant for the replacement of the meniscus.
引用
收藏
页码:64 / 71
页数:8
相关论文
共 31 条
[1]  
ADAMS ME, 1991, J RHEUMATOL, V18, P428
[2]   Autologous perichondral tissue for meniscal replacement [J].
Bruns, J ;
Kahrs, J ;
Kampen, J ;
Behrens, P ;
Plitz, W .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (05) :918-923
[3]  
BURR DB, 1982, CLIN ORTHOP RELAT R, P121
[4]  
COX JS, 1975, CLIN ORTHOP RELAT R, P178
[5]   Meniscal tissue regeneration in porous 50/50 copoly(L-lactide/epsilon-caprolactone) implants [J].
deGroot, JH ;
Zijlstra, FM ;
Kuipers, HW ;
Pennings, AJ ;
Klompmaker, J ;
Veth, RPH ;
Jansen, HWB .
BIOMATERIALS, 1997, 18 (08) :613-622
[6]  
DEHAVEN KE, 1990, BRIS MYER Z, P103
[7]   KNEE JOINT CHANGES AFTER MENISCECTOMY [J].
FAIRBANK, TJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1948, 30 (04) :664-670
[8]   Impact load transmission of the knee joint-influence of leg alignment and the role of meniscus and articular cartilage [J].
Fukuda, Y ;
Takai, S ;
Yoshino, N ;
Murase, K ;
Tsutsumi, S ;
Ikeuchi, K ;
Hirasawa, Y .
CLINICAL BIOMECHANICS, 2000, 15 (07) :516-521
[9]  
GHADIALLY FN, 1978, J ANAT, V125, P499
[10]   Meniscal replacement using a porous polymer prosthesis: A preliminary study in the dog [J].
Klompmaker, J ;
Veth, RPH ;
Jansen, HWB ;
Nielsen, HKL ;
deGroot, JH ;
Pennings, AJ .
BIOMATERIALS, 1996, 17 (12) :1169-1175