Measurement of electromagnetic environment of hybrid DC circuit breaker during bipolar short circuit fault

被引:0
|
作者
Teng, Zihan [1 ]
Chen, Weijiang [2 ]
Zhao, Jun [1 ]
Zhang, Jiangong [1 ]
Gan, Zheyuan [1 ]
Li, Kejie [3 ]
机构
[1] China Elect Power Res Inst, State Key Lab Power Grid Environm Protect, Beijing, Peoples R China
[2] State Grid Corp China, Beijing 100031, Peoples R China
[3] Hefei Univ Technol, Sch Elect Engn & Automat, Hefei 230009, Peoples R China
基金
中国国家自然科学基金;
关键词
HVDC converter station; Hybrid DC breaker; Short circuit fault; Magnetic field measurement; Electromagnetic compatibility;
D O I
10.1016/j.egyr.2022.08.197
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Hybrid DC circuit breakers (DCBs) have recently been used to break short-circuit fault currents to ensure safety in flexible DC transmission projects. However, electromagnetic transients from DCB operation can interfere with the secondary equipment and cause malfunctions. In this paper, the bipolar short-circuit test, which is the first short-circuit test for DC transmission line in flexible DC project in the world, has been carried out in the 200 kV HVDC converter station equipped with two hybrid DCBs. The transient magnetic field near the secondary equipment in the DCB hall were measured, and its characteristics were discussed. Furthermore, the relationships among the space magnetic field, the short-circuit current and the action of the power electronic equipment in the DCB were also analyzed The main findings are as follows. During the bipolar short-circuit process, the maximum space magnetic field intensity near the secondary device is 109 A/m, and the maximum rising rate of the magnetic field waveform is about 350 A/m/ms. The magnetic field strength reached its peak value at the moment when the DCB was blocked, as well as the short-circuit current. It can be indicated that the DCB can cut off the short-circuit fault current accurately and reliably. The results can provide reference for the immunity evaluation and anti-interference protection of secondary equipment, and its optimal arrangement in the DCB hall. (C) 2022 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:1328 / 1335
页数:8
相关论文
共 50 条
  • [21] Topology and Control Design of Converters for Short-circuit Fault Protection in DC Microgrids
    Choi, Wooin
    Cho, Bo-Hyung
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 1386 - 1391
  • [22] A combined short-circuit fault detection method for DC microgrid system in an offshore platform
    Li Z.
    Wang G.
    Yang Y.
    Yang R.
    Xu S.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2021, 42 (01): : 157 - 164
  • [23] New Type of Multiport Mechanical DC Circuit Breaker for Medium Voltage DC Distribution Network
    Li B.
    Ma J.
    Wen W.
    Liu H.
    Chen Z.
    Wang Y.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (08): : 2385 - 2392
  • [24] An Optimization Placement Method for Circuit Breakers and Fault Current Limiters of Looped-type DC Micro-grids for Short Circuit Faults
    Nian H.
    Kong L.
    2018, Chinese Society for Electrical Engineering (38): : 6861 - 6872
  • [25] Switch Short-Circuit Fault Detection Algorithm based on Drain-to-Source Voltage Monitoring for a Fault Tolerant DC/DC Converter
    Yahyaoui, R.
    De Bernardinis, A.
    Gaillard, A.
    Hissel, D.
    PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, : 2212 - 2217
  • [26] A study on effect of fault current limiter on bus voltage sag during short-circuit fault
    Polytechnic University, 4-1-1, Hashimotodai, Sagamihara 229-1196, Japan
    不详
    IEEJ Trans. Power Energy, 2008, 2 (486-492+15): : 486 - 492+15
  • [27] Short-Circuit Fault Current Limiting Control Method of DC Transformer with Separable Supporting Capacitor
    Zhuo C.
    Zhang X.
    Zhang X.
    Yang X.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2022, 37 (02): : 424 - 432
  • [28] DC Fault Current Blocking With the Coordination of Half-Bridge MMC and the Hybrid DC Breaker
    Iman-Eini, Hossein
    Liserre, Marco
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (07) : 5503 - 5514
  • [29] Interruption characteristic of self-triggering low voltage hybrid DC circuit breaker with non-polarized bidirectional breaking
    Yin, Jianning
    Lang, Xiaojian
    Zhao, Yongyong
    Duan, Jiandong
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 163
  • [30] Research on a Novel DC Circuit Breaker Based on Artificial Current Zero-Crossing
    Teng, Shangfu
    Zhang, Zhifeng
    Xiao, Liye
    IEEE ACCESS, 2020, 8 : 36070 - 36079