Combined local impedance and contact force for radiofrequency ablation assessment

被引:38
|
作者
Garrott, Kara [1 ]
Laughner, Jacob [1 ]
Gutbrod, Sarah [1 ]
Sugrue, Alan [2 ]
Shuros, Allan [1 ]
Sulkin, Matt [1 ]
Yasin, Omar [2 ]
Bush, Jamie [1 ]
Pottinger, Nathan [1 ]
Meyers, Jason [3 ]
Kapa, Suraj [2 ]
机构
[1] Boston Sci Corp, St Paul, MN USA
[2] Mayo Clin, Dept Cardiovasc Med, Coll Med, 200 First St SW, Rochester, MN 55905 USA
[3] Iowa Heart Ctr, Heart Rhythm Ctr, W Des Moines, IA USA
关键词
Ablation; Contact force; Electroanatomic mapping; Impedance; Radiofrequency; CATHETER ABLATION; LESION FORMATION; TEMPERATURE; SAFETY; MODEL; SIZE; FLOW;
D O I
10.1016/j.hrthm.2020.03.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The combination of contact force (CF) and local impedance (LI) may improve tissue characterization and lesion prediction during radiofrequency (RF) ablation. OBJECTIVE The purpose of this study was to evaluate the utility of LI combined with CF in assessing RF ablation efficacy. METHODS An LI catheter with CF sensing was evaluated in swine (n = 11) and in vitro (n = 14). The relationship between LI and CF in different tissue types was evaluated in vivo. Discrete lesions were created in vitro and in vivo at a range of forces, powers, and durations. Finally, an intercaval line was created in 3 groups at 30 W: 30s, Delta 20 Omega, and Delta 30 Omega. In the Delta 20 Omega and Delta 30 Omega groups, the user ablated until a 20 or 30 Omega LI drop. In the 30s group, the user was blinded to LI. RESULTS In vivo, distinction in LI was found between the blood pool and the myocardium (blood pool: 122 +/- 7.02 Omega; perpendicular contact: 220 +/- 29 Omega; parallel contact: 207 +/- 31 Omega). LI drop correlated with lesion depth both in vitro (R = 0.84) and in vivo (R = 0.79), informing sufficient lesion creation (LI drop >20 Omega) and warning of excessive heating (LI drop >65 Omega). When creating an intercaval line, the total RF time was significantly reduced when using LI guidance (6.4 +/- 2 minutes in Delta 20 Omega and 8.1 +/- 1 minutes in Delta 30 Omega) compared with a standard 30-second workflow (18 +/- 7 minutes). Acute conduction block was achieved in all Delta 30 Omega and 30s lines. CONCLUSION The addition of LI to CF provides feedback on both electrical and mechanical loads. This provides information on tissue type and catheter-tissue coupling; provides feedback on whether volumetric tissue heating is inadequate, sufficient, or excessive; and reduces ablation time.
引用
收藏
页码:1371 / 1380
页数:10
相关论文
共 50 条
  • [41] A Comparative Analysis of Radiofrequency Ablation with Contact Force Sensing and Second-Generation Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: A Study at the Najaf Cardiac Center
    Shekhani, Ali Hamadameen
    Talib, Ahmed Abdulkarim
    Mustafa, Muhammad Kareem
    MEDICINA BALEAR, 2024, 39 (04):
  • [42] Steam pops during irrigated radiofrequency ablation: Feasibility of impedance monitoring for prevention
    Seiler, Jens
    Roberts-Thomson, Kurt C.
    Raymond, Jean-Marc
    Vest, John
    Delacretaz, Etienne
    Stevenson, William G.
    HEART RHYTHM, 2008, 5 (10) : 1411 - 1416
  • [43] Impedance Guided Radiofrequency Ablation for Atrial Fibrillation: Something Old Is New Again
    Gaeta, Stephen
    Bahnson, Tristram D.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (12) : 1399 - 1402
  • [44] Re-definition of blanking period in radiofrequency catheter ablation of atrial fibrillation in the contact force era
    Uetake, Shunsuke
    Miyauchi, Yasushi
    Mitsuishi, Tatsuya
    Maruyama, Mitsunori
    Seino, Yoshihiko
    Shimizu, Wataru
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (09) : 2363 - 2370
  • [45] Cryoballoon vs. radiofrequency contact force ablation for paroxysmal atrial fibrillation: a propensity score analysis
    Matta, Mario
    Anselmino, Matteo
    Ferraris, Federico
    Scaglione, Marco
    Gaita, Fiorenzo
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2018, 19 (04) : 141 - 147
  • [46] Locations of High Contact Force During Left Atrial Mapping in Atrial Fibrillation Patients Electrogram Amplitude and Impedance Are Poor Predictors of Electrode-Tissue Contact Force for Ablation of Atrial Fibrillation
    Nakagawa, Hiroshi
    Kautzner, Josef
    Natale, Andrea
    Peichl, Petr
    Cihak, Robert
    Wichterle, Dan
    Ikeda, Atsushi
    Santangeli, Pasquale
    Di Biase, Luigi
    Jackman, Warren M.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (04) : 746 - 753
  • [47] A prospective study on safety of catheter ablation procedures: Contact force guided ablation could reduce the risk of cardiac perforation
    Akca, Ferdi
    Janse, Petter
    Theuns, Dominic A. M. J.
    Szili-Torok, Tamas
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 179 : 441 - 448
  • [48] The Influence of Impedance on the Efficacy of Radiofrequency Ablation for Benign Thyroid Nodules
    Duenas, Juan Pablo
    Buitrago-Gomez, Nathalia
    Arias-Botero, Jose Hugo
    Randolph, Gregory
    Russell, Marika
    Abdelhamid Ahmed, Amr
    Valcavi, Roberto
    Duque, Carlos Simon
    Tufano, Ralph P.
    LARYNGOSCOPE, 2024, 134 (12) : 5231 - 5238
  • [49] Persistent Atrial Fibrillation Ablation With or Without Contact Force Sensing
    Hussein, Ayman A.
    Barakat, Amr F.
    Saliba, Walid I.
    Tarakji, Khaldoun G.
    Bassiouny, Mohamed
    Baranowski, Bryan
    Tchou, Patrick
    Bhargava, Mandeep
    Dresing, Thomas
    Callahan, Thomas
    Cantillon, Daniel
    Kanj, Mohamed
    Lindsay, Bruce D.
    Wazni, Oussama M.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (05) : 483 - 488
  • [50] Factors Influencing Contact Force in Robotic Magnetic Navigation Ablation
    Orczykowski, Michal
    Bak, Maciej
    Kaczmarek, Krzysztof
    Urbanek, Piotr
    Robert, Bodalski
    Dubowski, Krzysztof
    Warminski, Grzegorz
    Derejko, Pawel
    Ptaszynski, Pawel
    Sterlinski, Maciej
    Bilinska, Maria
    Szumowski, Lukasz
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2025, : 855 - 862