Combined local impedance and contact force for radiofrequency ablation assessment

被引:38
|
作者
Garrott, Kara [1 ]
Laughner, Jacob [1 ]
Gutbrod, Sarah [1 ]
Sugrue, Alan [2 ]
Shuros, Allan [1 ]
Sulkin, Matt [1 ]
Yasin, Omar [2 ]
Bush, Jamie [1 ]
Pottinger, Nathan [1 ]
Meyers, Jason [3 ]
Kapa, Suraj [2 ]
机构
[1] Boston Sci Corp, St Paul, MN USA
[2] Mayo Clin, Dept Cardiovasc Med, Coll Med, 200 First St SW, Rochester, MN 55905 USA
[3] Iowa Heart Ctr, Heart Rhythm Ctr, W Des Moines, IA USA
关键词
Ablation; Contact force; Electroanatomic mapping; Impedance; Radiofrequency; CATHETER ABLATION; LESION FORMATION; TEMPERATURE; SAFETY; MODEL; SIZE; FLOW;
D O I
10.1016/j.hrthm.2020.03.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The combination of contact force (CF) and local impedance (LI) may improve tissue characterization and lesion prediction during radiofrequency (RF) ablation. OBJECTIVE The purpose of this study was to evaluate the utility of LI combined with CF in assessing RF ablation efficacy. METHODS An LI catheter with CF sensing was evaluated in swine (n = 11) and in vitro (n = 14). The relationship between LI and CF in different tissue types was evaluated in vivo. Discrete lesions were created in vitro and in vivo at a range of forces, powers, and durations. Finally, an intercaval line was created in 3 groups at 30 W: 30s, Delta 20 Omega, and Delta 30 Omega. In the Delta 20 Omega and Delta 30 Omega groups, the user ablated until a 20 or 30 Omega LI drop. In the 30s group, the user was blinded to LI. RESULTS In vivo, distinction in LI was found between the blood pool and the myocardium (blood pool: 122 +/- 7.02 Omega; perpendicular contact: 220 +/- 29 Omega; parallel contact: 207 +/- 31 Omega). LI drop correlated with lesion depth both in vitro (R = 0.84) and in vivo (R = 0.79), informing sufficient lesion creation (LI drop >20 Omega) and warning of excessive heating (LI drop >65 Omega). When creating an intercaval line, the total RF time was significantly reduced when using LI guidance (6.4 +/- 2 minutes in Delta 20 Omega and 8.1 +/- 1 minutes in Delta 30 Omega) compared with a standard 30-second workflow (18 +/- 7 minutes). Acute conduction block was achieved in all Delta 30 Omega and 30s lines. CONCLUSION The addition of LI to CF provides feedback on both electrical and mechanical loads. This provides information on tissue type and catheter-tissue coupling; provides feedback on whether volumetric tissue heating is inadequate, sufficient, or excessive; and reduces ablation time.
引用
收藏
页码:1371 / 1380
页数:10
相关论文
共 50 条
  • [31] Computer simulation study on the effect of electrode-tissue contact force on thermal lesion size in cardiac radiofrequency ablation
    Yan, Shengjie
    Gu, Kaihao
    Wu, Xiaomei
    Wang, Weiqi
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2020, 37 (01) : 37 - 48
  • [32] Local impedance-guided radiofrequency ablation with standard and high power: Results of a preclinical investigation
    Osei, Kofi
    Sulkin, Matthew S.
    Hamann, Jason J.
    Hughes, Christopher
    Shuros, Allan
    Nagy, Tamas
    Kapa, Suraj
    Meyers, Jason
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (08) : 2060 - 2068
  • [33] Combining contact force and local impedance to treat idiopathic premature ventricular contractions from the outflow tracts: impact of ablation strategy on outcomes
    Schillaci, Vincenzo
    Arestia, Alberto
    Maddaluno, Francesco
    Shopova, Gergana
    Agresta, Alessia
    Salito, Armando
    Stabile, Giuseppe
    Marano, Giovanni
    Bottaro, Giuseppe
    Malacrida, Maurizio
    Solimene, Francesco
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (09) : 2011 - 2020
  • [34] Characterization of Catheter-Tissue Contact Force During Epicardial Radiofrequency Ablation in an Ovine Model
    Wong, Michael C. G.
    Edwards, Glenn
    Spence, Steven J.
    Kalman, Jonathan M.
    Kumar, Saurabh
    Joseph, Stephen A.
    Morton, Joseph B.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (06) : 1222 - 1228
  • [35] Combining contact force and local impedance to treat idiopathic premature ventricular contractions from the outflow tracts: impact of ablation strategy on outcomes
    Vincenzo Schillaci
    Alberto Arestia
    Francesco Maddaluno
    Gergana Shopova
    Alessia Agresta
    Armando Salito
    Giuseppe Stabile
    Giovanni Marano
    Giuseppe Bottaro
    Maurizio Malacrida
    Francesco Solimene
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 2011 - 2020
  • [36] Role of contact force-guided radiofrequency catheter ablation for treatment of atrial fibrillation: A systematic review and meta-analysis
    Lin, Hui
    Chen, Yi-He
    Hou, Jian-Wen
    Lu, Zhao-Yang
    Xiang, Yin
    Li, Yi-Gang
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (09) : 994 - 1005
  • [37] Regional Difference of Optimal Contact Force to Prevent Acute Pulmonary Vein Reconnection During Radiofrequency Catheter Ablation for Atrial Fibrillation
    Sotomi, Yohei
    Kikkawa, Takayuki
    Inoue, Koichi
    Tanaka, Koji
    Toyoshima, Yuko
    Oka, Takafumi
    Tanaka, Nobuaki
    Nozato, Yoichi
    Orihara, Yoshiyuki
    Iwakura, Katsuomi
    Sakata, Yasushi
    Fujii, Kenshi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (09) : 941 - 947
  • [38] Contact force sensing for ablation of persistent atrial fibrillation: A randomized, multicenter trial
    Conti, Sergio
    Weerasooriya, Rukshen
    Novak, Paul
    Champagne, Jean
    Lim, Hong Euy
    Macle, Laurent
    Khaykin, Yaariv
    Pantano, Alfredo
    Verma, Atul
    HEART RHYTHM, 2018, 15 (02) : 201 - 208
  • [39] Effect of contact force on pulsed field ablation lesions in porcine cardiac tissue
    Mattison, Lars
    Verma, Atul
    Tarakji, Khaldoun G.
    Reichlin, Tobias
    Hindricks, Gerhard
    Sack, Kevin L.
    Onal, Birce
    Schmidt, Megan M.
    Miklavcic, Damijan
    Sigg, Daniel C.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (03) : 693 - 699
  • [40] Local impedance to guide focal radiofrequency ablation: There is life in the old dog yet
    Chu, Gavin S.
    Gupta, Dhiraj
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (06) : 1549 - 1552