Separation of dansyl-DL-amino acids by open tubular capillary chromatography based on tube radial distribution phenomenon of the ternary mixed carrier solvents

被引:21
作者
Kudo, Yudai [1 ]
Kan, Hyo [1 ]
Jinno, Naoya [1 ]
Hashimoto, Masahiko [1 ]
Tsukagoshi, Kazuhiko [1 ]
机构
[1] Doshisha Univ, Dept Chem Engn & Mat Sci, Fac Sci & Engn, Kyotanabe, Kyoto 6100321, Japan
关键词
LAMINAR-FLOW; HYDRODYNAMIC CHROMATOGRAPHY; ORGANIC-SOLVENTS; EXTRACTION; SOLVATION; PROTEIN; LAYER;
D O I
10.1039/c2ay05813h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Separation of enantiomers, dansyl-DL-amino acids, was carried out by open-tubular capillary chromatography based on the tube radial distribution of the carrier solvents. An untreated poly(tetrafluoroethylene) capillary tube (100 mu m inner diameter and 90 cm effective length) as a separation column and a water-acetonitrile-ethyl acetate mixture containing cyclodextrin as a carrier solution were used in the chromatography. An analyte solution of dansyl-DL-amino acids, such as dansyl-DL-methionine, was injected into the capillary tube by a gravity method. The analyte solution was subsequently delivered through the capillary tube with the carrier solution by a microsyringe pump. The ternary mixed carrier solution (water-rich carrier solution) was radially distributed in the capillary tube based on the tube radial distribution phenomenon, causing the formation of inner (water-rich) and outer (organic solvent-rich) phases. The outer or capillary wall phase acted as a pseudo-stationary phase in the chromatography. The analytes were separated through the capillary tube with on-capillary detection by an absorption or a fluorescence detector. The D-enantiomer and the L-enantiomer were eluted in this order with a baseline separation. The separation mechanism of the enantiomers in the open-tubular capillary using cyclodextrin was discussed.
引用
收藏
页码:906 / 912
页数:7
相关论文
共 39 条
[1]   Direct enantiomeric TLC resolution of DL-penicillamine using (R)-mandelic acid and L-tartaric acid as chiral impregnating reagents and as chiral mobile phase additive [J].
Bhushan, Ravi ;
Agarwal, Charu .
BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (11) :1237-1242
[2]   Recent advances in peptide chiral selectors for electrophoresis and liquid chromatography [J].
Bluhm, L ;
Huang, JM ;
Li, TY .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (03) :592-598
[3]   Homogeneous biocatalysis in organic solvents and water-organic mixtures [J].
Castro, GR ;
Knubovets, T .
CRITICAL REVIEWS IN BIOTECHNOLOGY, 2003, 23 (03) :195-231
[4]   Micro-solvent Cluster Extraction Using Aqueous Mixed Solvents of Ionic Liquid [J].
Charoenraks, Thiraporn ;
Tabata, Masaaki ;
Fujii, Kenta .
ANALYTICAL SCIENCES, 2008, 24 (10) :1239-1244
[5]  
Cikalo MG, 1998, ANALYST, V123, p87R
[6]   Use of tube radial distribution of ternary mixed carrier solvents for introduction of absorption reagent for metal ion separation and online detection into capillary [J].
Fujinaga, Satoshi ;
Jinno, Naoya ;
Hashimoto, Masahiko ;
Tsukagoshi, Kazuhiko .
JOURNAL OF SEPARATION SCIENCE, 2011, 34 (20) :2833-2839
[7]   Solute distribution coupled with laminar flow in wide-bore capillaries: What can be separated without chemical or physical fields? [J].
Harada, M ;
Kido, T ;
Masudo, T ;
Okada, T .
ANALYTICAL SCIENCES, 2005, 21 (05) :491-496
[8]   Ion solvation in aqueous-organic mixtures [J].
Hefter, G .
PURE AND APPLIED CHEMISTRY, 2005, 77 (03) :605-617
[9]  
Hibi K., 1978, J HIGH RES CHROMATOG, V1, p21e27, DOI [10.1002/jhrc.1240010106, DOI 10.1002/JHRC.1240010106]
[10]   Introduction of fluorescence and chemiluminescence detection to capillary chromatography based on tube radial distribution of water-hydrophilic- hydrophobic organic mixture carrier solvents [J].
Ishimoto, Seiji ;
Kudo, Yudai ;
Jinno, Naoya ;
Hashimoto, Masahiko ;
Tsukagoshi, Kazuhiko .
ANALYTICAL METHODS, 2010, 2 (09) :1377-1381