Wearable Transdermal Alcohol Monitors: A Systematic Review of Detection Validity, and Relationship Between Transdermal and Breath Alcohol Concentration and Influencing Factors

被引:39
作者
van Egmond, Kelly [1 ]
Wright, Cassandra J. C. [1 ,2 ,3 ]
Livingston, Michael [1 ,4 ]
Kuntsche, Emmanuel [1 ,5 ]
机构
[1] La Trobe Univ, Ctr Alcohol Policy & Res CAPR, Melbourne, Vic, Australia
[2] Burnet Inst, Melbourne, Vic, Australia
[3] Monash Univ, Sch Publ Hlth & Prevent Med, Melbourne, Vic, Australia
[4] Karolinska Inst, Sch Clin Neurosci, Stockholm, Sweden
[5] Eotvos Lorand Univ, Inst Psychol, Budapest, Hungary
来源
ALCOHOL-CLINICAL AND EXPERIMENTAL RESEARCH | 2020年 / 44卷 / 10期
关键词
Transdermal Alcohol Concentration; Alcohol Consumption; Continuous Measurement; SELF-REPORT; DRINKING; SOFTWARE; NUMBER;
D O I
10.1111/acer.14432
中图分类号
R194 [卫生标准、卫生检查、医药管理];
学科分类号
摘要
Background Research on alcohol consumption mostly relies on self-reported data, which are subject to recall bias. Wearable transdermal alcohol concentration (TAC) monitors address this limitation by continuously measuring the ethanol excreted via the skin. This systematic review aims to provide an overview of TAC monitors' reliability to detect alcohol consumption and methods to estimate breath alcohol concentration (BrAC) and number of standard drinks consumed in a given time frame. Methods The databases MEDLINE, PsycINFO, SCOPUS, Engineering Village, and CINAHL were systematically searched to identify 1,048 empirical research papers published from 2013 onwards, of which 13 were included after full-text screening. The selected studies included 3 TAC monitors: SCRAM (TM), WristTAS (TM), and Skyn (TM). Results TAC measures of SCRAM, WrisTAS, and Skyn are found to be positively correlated with BrAC (r = 0.56 to 0.79) and/or self-reports (r = 0.62). Using the AMS criteria for detection results in low sensitivity, adjusted criteria can increase the sensitivity of the SCRAM from 39.9 to 68.5%. The WrisTAS and an early prototype of the Skyn showed high failure rates (17 to 38%). Recent advances toward transforming the TAC data into more clinically relevant measures have led to the development of mathematical models and theBrAC Estimator Software. Using TAC data, both approaches produce estimates explaining 70 to 82% of actual BrAC and self-reported drinking or to highly correlate with the actual BrAC measures (beta = 0.90 to 0.91). Conclusions Transdermal alcohol monitors offer an opportunity to measure alcohol consumption in a valid and continuous way with mathematical models and software estimating BrAC values improving interpretation of TAC data. However, the SCRAM seems unable to detect low-to-moderate drinking levels using the thresholds and criteria set by the manufacturer. Moreover, the WrisTAS and the Skyn prototype show a high failure rate, raising questions about reliability. Future studies will assess the validity of new-generation wristbands, including the next Skyn generations.
引用
收藏
页码:1918 / 1932
页数:15
相关论文
共 33 条
  • [1] Barnett NP, 2015, ALCOHOL CLIN EXP RES, V39, p192A
  • [2] Predictors of Detection of Alcohol Use Episodes Using a Transdermal Alcohol Sensor
    Barnett, Nancy P.
    Meade, E. B.
    Glynn, Tiffany R.
    [J]. EXPERIMENTAL AND CLINICAL PSYCHOPHARMACOLOGY, 2014, 22 (01) : 86 - 96
  • [3] Contingency management for alcohol use reduction: A pilot study using a transdermal alcohol sensor
    Barnett, Nancy P.
    Tidey, Jennifer
    Murphy, James G.
    Swift, Robert
    Colby, Suzanne M.
    [J]. DRUG AND ALCOHOL DEPENDENCE, 2011, 118 (2-3) : 391 - 399
  • [4] Adjustments for Drink Size and Ethanol Content: New Results from a Self-Report Diary and Transdermal Sensor Validation Study
    Bond, Jason C.
    Greenfield, Thomas K.
    Patterson, Deidre
    Kerr, William C.
    [J]. ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 2014, 38 (12) : 3060 - 3067
  • [5] Wearable electrochemical alcohol biosensors
    Campbell, Alan S.
    Kim, Jayoung
    Wang, Joseph
    [J]. CURRENT OPINION IN ELECTROCHEMISTRY, 2018, 10 : 126 - 135
  • [6] Dai Z, 2016, MATH BIOSCI ENG, V13, P911, DOI [10.3934/mbe.2016023, 10.3034/mbe.2016023]
  • [7] The Potential Clinical Utility of Transdermal Alcohol Monitoring Data to Estimate the Number of Alcoholic Drinks Consumed
    Dougherty, Donald M.
    Hill-Kapturczak, Nathalie
    Liang, Yuanyuan
    Karns, Tara E.
    Lake, Sarah L.
    Cates, Sharon E.
    Roache, John D.
    [J]. ADDICTIVE DISORDERS & THEIR TREATMENT, 2015, 14 (03) : 124 - 130
  • [8] Comparing the Detection of Transdermal and Breath Alcohol Concentrations During Periods of Alcohol Consumption Ranging From Moderate Drinking to Binge Drinking
    Dougherty, Donald M.
    Charles, Nora E.
    Acheson, Ashley
    John, Samantha
    Furr, R. Michael
    Hill-Kapturczak, Nathalie
    [J]. EXPERIMENTAL AND CLINICAL PSYCHOPHARMACOLOGY, 2012, 20 (05) : 373 - 381
  • [9] Comparisons of alcohol consumption by timeline follow back vs. smartphone-based daily interviews
    Dulin, Patrick L.
    Alvarado, Corene E.
    Fitterling, James M.
    Gonzalez, Vivian M.
    [J]. ADDICTION RESEARCH & THEORY, 2017, 25 (03) : 195 - 200
  • [10] Temporal Dynamics of Transdermal Alcohol Concentration Measured via New-Generation Wrist-Worn Biosensor
    Fairbairn, Catharine E.
    Kang, Dahyeon