Ex situ prepared nafion-coated antimony film electrode for adsorptive stripping voltammetry of model metal ions in the presence of pyrogallol red

被引:20
作者
Arancibia, Veronica [1 ]
Nagles, Edgar [1 ]
Rojas, Carlos [1 ]
Gomez, Marisol [1 ]
机构
[1] Pontificia Univ Catolica Chile, Fac Quim, Santiago 7820436, Chile
关键词
Nafion-coated antimony film electrode; Adsorptive stripping voltammetry; Pyrogallol red; Chemically modified electrode; Cadmium and lead; SEQUENTIAL-INJECTION-ANALYSIS; CARBON-PASTE ELECTRODES; MERCURY-FILM; HEAVY-METALS; TRACE-METALS; BISMUTH; CADMIUM; LEAD; CD; EXTRACTS;
D O I
10.1016/j.snb.2013.03.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A nafion-coated antimony film electrode (NSbFE) was prepared ex situ and applied to the model metal ions Pb(II) and Cd(II) by adsorptive stripping voltammetry in the presence of pyrogallol red (PGR). To enhance the electroanalytical performance of the NSbFE, we optimized several operational parameters, including antimony concentration, deposition potential and time used in the preparation of the electrode, and effect of pH, ligand concentration (C-PGR), adsorptive potential, and time (E-ads, t(ads)). The NSbFE exhibited well developed signals for the reduction of the adsorbed complexes at -0.63 and -0.92 V for Pb-PGR and Cd-PGR, respectively, with higher current compared to unmodified electrodes. The optimum parameters for NSbFE preparation consisting of 100 mg L-1 Sb(III), 0.5 mol L-1 HCl at -1.5 V (150 s) and for the determination of Pb(II) and Cd(II) were pH = 4.5 (acetate buffer); C-PGR = 2.8 mu mol L-1; E-ads = -0.40 V and t(ads) = 100 s. The electrode presents good linear behavior in the examined concentration range from 0.9 to 12.0 mu g L-1 for both metal ions, with a limit of detection (3 sigma) of 0.4 and 0.9 mu g L-1 for Pb(II) and 0.5 and 1.0 mu g L-1 for Cd(II) using 2-mm and 3-mm diameter glassy carbon electrodes, respectively. The relative standard deviation for a Pb(II) a Cd(II) solution (9.8 mu g L-1) was 2.0% for six successive assays. The method was validated using certified reference water for trace elements (TMDA-61) with satisfactory results. Finally, the method was applied to the determination of Pb(II) and Cd(II) in tap and mineral water. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:368 / 373
页数:6
相关论文
共 53 条
[1]   Individual and simultaneous determination of lead, cadmium, and zinc by anodic stripping voltammetry at a bismuth bulk electrode [J].
Armstrong, Kristie C. ;
Tatum, Clarissa E. ;
Dansby-Sparks, Royce N. ;
Chambers, James Q. ;
Xue, Zi-Ling .
TALANTA, 2010, 82 (02) :675-680
[2]   New procedures for voltammetric determination of copper (II) using antimony film-coated carbon paste electrodes [J].
Ashrafi, Amir M. ;
Vytras, Karel .
ELECTROCHIMICA ACTA, 2012, 73 :112-117
[3]  
Ashrafi AM, 2012, INT J ELECTROCHEM SC, V7, P68
[4]   Stripping voltammetric determination of mercury(II) at antimony-coated carbon paste electrode [J].
Ashrafi, Amir M. ;
Vytras, Karel .
TALANTA, 2011, 85 (05) :2700-2702
[5]   Determination of Lead and Cadmium in Sea- and Freshwater by Anodic Stripping Voltammetry with a Vibrating Bismuth Electrode [J].
Bi, Zhaoshun ;
Chapman, Conrad S. ;
Salauen, Pascal ;
van den Berg, Constant M. G. .
ELECTROANALYSIS, 2010, 22 (24) :2897-2907
[6]   Determination of Cu, Pb, Cd, and Zn in river sediment extracts by sequential injection anodic stripping voltammetry with thin mercury film electrode [J].
da Silva, CL ;
Masini, JC .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (03) :284-290
[7]   Antimony film electrode for stripping voltammetric measurement of Hg(II) in the presence of Cu(II) [J].
Dal Borgo, Sebastiano ;
Jovanovski, Vasko ;
Hocevar, Samo B. .
ELECTROCHIMICA ACTA, 2013, 88 :713-717
[8]   Simultaneous determination of cadmium, lead, copper, and thallium in highly saline samples by anodic stripping voltammetry (ASV) using mercury-film and bismuth-film electrodes [J].
de Carvalho, Leandro M. ;
do Nasciniento, Paulo C. ;
Koschinsky, Andrea ;
Bau, Michael ;
Stefanello, Raquel F. ;
Spengler, Cristiane ;
Bohrer, Denise ;
Jost, Cristiane .
ELECTROANALYSIS, 2007, 19 (16) :1719-1726
[9]   LabVIEW-based sequential-injection analysis system for the determination of trace metals by square-wave anodic and adsorptive stripping voltammetry on mercury-film electrodes [J].
Economou, A ;
Voulgaropoulos, A .
JOURNAL OF AUTOMATED METHODS & MANAGEMENT IN CHEMISTRY, 2003, 25 (06) :133-140
[10]   Square-wave stripping voltammetry for direct determination of eight heavy metals in soil and indoor-airborne particulate matter [J].
Farghaly, OA ;
Ghandour, MA .
ENVIRONMENTAL RESEARCH, 2005, 97 (03) :229-235