Analysis of interfractional set-up errors and intrafractional organ motions during IMRT for head and neck tumors to define an appropriate planning target volume (PTV)- and planning organs at risk volume (PRV)-margins

被引:93
作者
Suzuki, M
Nishimura, Y
Nakamatsu, K
Okumura, M
Hashiba, H
Koike, R
Kanamori, S
Shibata, T
机构
[1] Kyoto Univ, Inst Res Reactor, Radiat Oncol Res Lab, Osaka 5900494, Japan
[2] Kinki Univ, Sch Med, Dept Radiat Oncol, Osaka 589, Japan
[3] Kinki Univ, Sch Med, Dept Cent Radiol Sci, Osaka 589, Japan
关键词
set-up error; organ motion; PTV-margin; PRV-margin; head and neck IMRT;
D O I
10.1016/j.radonc.2006.03.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To analyze the interfractional set-up errors and intrafractional organ motions and to define appropriate planning target volume (PTV)- and planning organs at risk volume (PRV)-margins in intensity-modulated radiotherapy (IMRT) for head and neck tumors. Patients and methods: Twenty-two patients with head and neck or brain tumors who were treated with IMRT were enrolled. The set-up errors were defined as the displacements of the coordinates of bony landmarks on the beam films from those on the simulation films. The organ motions were determined as the displacements of the coordinates of the landmarks on the images recorded every 3 min for 15 min on the X-ray simulator from those on the initial image. Results: The standard deviations (SDs) of the systematic set-up errors (Sigma-INTER) and organ motions (Sigma-intra) distributed with a range of 0.7-1.3 and 0.2-0.8 mm, respectively. The average of the SDs of the random set-up errors (sigma-INTER) and organ motions (sigma-intra) ranged from 0.7 to 1.6 mm and from 0.3 to 0.6 mm, respectively. Appropriate PTV-margins and PRV-margins for all the landmarks ranged from 2.0 to 3.6 mm and from 1.8 to 2.4 mm, respectively. Conclusions: We have adopted a PTV-margin of 5 mm and a PRV-margin of 3 mm for head and neck IMRT at our department. (c) 2006 Elsevier Ireland Ltd.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 32 条
[1]   SETUP DEVIATIONS IN WEDGED PAIR IRRADIATION OF PAROTID-GLAND AND TONSILLAR TUMORS, MEASURED WITH AN ELECTRONIC PORTAL IMAGING DEVICE [J].
BEL, A ;
KEUS, R ;
VIJLBRIEF, RE ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (02) :153-159
[2]   Intensity-modulated stereotactic radiosurgery using dynamic micro-multileaf collimation [J].
Benedict, SH ;
Cardinale, RM ;
Wu, QW ;
Zwicker, RD ;
Broaddus, WC ;
Mohan, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (03) :751-758
[3]   Comparison of two dead and neck immobilization systems [J].
Bentel, GC ;
Marks, LB ;
Hendren, K ;
Brizel, DM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (04) :867-873
[4]   A comparison of three stereotactic radiotherapy techniques; arcs vs. noncoplanar fixed fields vs. intensity modulation [J].
Cardinale, RM ;
Benedict, SH ;
Wu, QW ;
Zwicker, RD ;
Gaballa, HE ;
Mohan, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02) :431-436
[5]   Electronic portal image assisted reduction of systematic set-up errors in head and neck irradiation [J].
de Boer, HCJ ;
de Koste, JRV ;
Creutzberg, CL ;
Visser, AG ;
Levendag, PC ;
Heijmen, BJM .
RADIOTHERAPY AND ONCOLOGY, 2001, 61 (03) :299-308
[6]   Comparison of setup accuracy of three different thermoplastic masks for the treatment of brain and head and neck tumors [J].
Gilbeau, L ;
Octave-Prignot, M ;
Loncol, T ;
Renard, L ;
Scalliet, P ;
Grégoire, V .
RADIOTHERAPY AND ONCOLOGY, 2001, 58 (02) :155-162
[7]   The impact of daily setup variations on head-and-neck intensity-modulated radiation therapy [J].
Hong, TS ;
Tomé, WA ;
Chappell, RJ ;
Chinnaiyan, P ;
Mehta, MP ;
Harari, PM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03) :779-788
[8]   Assessment of a customised immobilisation system for head and neck IMRT using electronic portal imaging [J].
Humphreys, M ;
Urbano, MTG ;
Mubata, C ;
Mites, E ;
Harrington, KJ ;
Bidmead, M ;
Nutting, CM .
RADIOTHERAPY AND ONCOLOGY, 2005, 77 (01) :39-44
[9]   Comparison of intensity-modulated tomotherapy with stereotactically guided conformal radiotherapy for brain tumors [J].
Khoo, VS ;
Oldham, M ;
Adams, EJ ;
Bedford, JL ;
Webb, S ;
Brada, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02) :415-425
[10]   Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions [J].
Kitamura, K ;
Shirato, H ;
Seppenwoolde, Y ;
Onimaru, R ;
Oda, M ;
Fujita, K ;
Shimizu, S ;
Shinohara, N ;
Harabayashi, T ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1117-1123