Quantification of an active substance in a tablet by NIR and Raman spectroscopy

被引:0
作者
Jedvert, I [1 ]
Josefson, M [1 ]
Langkilde, F [1 ]
机构
[1] Astra Hassle AB, Pharmaceut R&D, Analyt Chem, S-43183 Molndal, Sweden
来源
JOURNAL OF NEAR INFRARED SPECTROSCOPY, VOL 6 1998 | 1998年
关键词
near infrared (NIR) spectroscopy; Raman spectroscopy; chemometrics; multivariate calibration; PLS; baseline corrections; quantify;
D O I
暂无
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
Spectroscopic techniques in combination with chemometrics give opportunities to analyse tablets without time-consuming sample preparation. The aim of the present study was to develop a method to quantify the active substance, isosorbide-5-mononitrate, in Imdur(R) 120 mg tablets either by NIR diffuse reflectance or Raman spectroscopy, The calibration set was selected to simulate, with the available samples, as closely as possible a full factorial design with three factors. The reference method was liquid chromatography (LC). Calibration models with different baseline correction methods, different parts of wavelength range and different measures of weights have been evaluated. The calibration model found for each spectroscopic technique is discussed. The accuracy for the spectroscopic techniques were equal in merit to the LC method, Both the NIR and the Raman calibrations also showed a good long-term stability. With the baseline correction methods used for the spectra, it was possible to analyse tablets after 1.5 years,In conclusion it is possible to quantify Imdur(R) 120 mg with either NIR or Raman spectroscopy.
引用
收藏
页码:279 / 289
页数:11
相关论文
共 12 条
[1]   STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[2]   CONTROL ANALYSIS OF A PHARMACEUTICAL PREPARATION BY NEAR-INFRARED REFLECTANCE SPECTROSCOPY - A COMPARATIVE-STUDY OF A SPINNING MODULE AND FIBER OPTIC PROBE [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
DELAPEZUELA, C ;
RUSSO, E .
ANALYTICA CHIMICA ACTA, 1994, 298 (02) :183-191
[3]  
*CAMO, MAN UNSCR VERS 5 5, P347
[4]  
COLTHUP NB, 1990, INTRO INFRARTED RAMA
[5]  
DAVIES AMC, 1993, 2 EUR S NEAR INFR NI
[6]   MEASUREMENT OF POLY(ARYL ETHER ETHER KETONE) CRYSTALLINITY IN ISOTROPIC AND UNIAXIAL SAMPLES USING FOURIER-TRANSFORM RAMAN-SPECTROSCOPY - A COMPARISON OF UNIVARIATE AND PARTIAL LEAST-SQUARES CALIBRATIONS [J].
EVERALL, NJ ;
CHALMERS, JM ;
FERWERDA, R ;
VANDERMAAS, JH ;
HENDRA, PJ .
JOURNAL OF RAMAN SPECTROSCOPY, 1994, 25 (01) :43-51
[7]   Vibrational spectrometry for the assessment of active substance in metoprolol tablets: A comparison between transmission and diffuse reflectance near-infrared spectrometry [J].
Gottfries, J ;
Depui, H ;
Fransson, M ;
Jongeneelen, M ;
Josefson, M ;
Langkilde, FW ;
Witte, DT .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (11) :1495-1503
[8]   RELATED VERSIONS OF THE MULTIPLICATIVE SCATTER CORRECTION METHOD FOR PREPROCESSING SPECTROSCOPIC DATA [J].
HELLAND, IS ;
NAES, T ;
ISAKSSON, T .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1995, 29 (02) :233-241
[9]  
JOSEFSON M, 1996, KEM TIDSKRIFT KEMIVA, V108, P44
[10]   SUITABILITY OF NEAR-INFRARED METHODS FOR THE DETERMINATION OF MOISTURE IN A FREEZE-DRIED INJECTION PRODUCT CONTAINING DIFFERENT AMOUNTS OF THE ACTIVE INGREDIENT [J].
LAST, IR ;
PREBBLE, KA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (11-12) :1071-1076