共 50 条
Effects of anodal transcranial direct current stimulation over lower limb primary motor cortex on motor learning in healthy individuals
被引:24
|作者:
Foerster, Aguida
[1
,2
]
Dutta, Anirban
[3
]
Kuo, Min-Fang
[2
]
Paulus, Walter
[1
]
Nitsche, Michael A.
[2
,4
]
机构:
[1] Georg August Univ, Univ Med Gottingen, Dept Clin Neurophysiol, Gottingen, Germany
[2] Leibniz Inst Arbeitsforsch, Deptartment Psychol & Neurosci, Leibniz Res Ctr Working Environm & Human Factors, Ardeystr 67, D-44139 Dortmund, Germany
[3] SUNY Buffalo, Dept Biomed Engn, Buffalo, NY USA
[4] Univ Med Hosp Bergmannsheil, Dept Neurol, Bochum, Germany
关键词:
biofeedback;
motor task;
neuromodulation;
transcranial direct current stimulation;
NONINVASIVE BRAIN-STIMULATION;
MAGNETIC STIMULATION;
SPINAL-CORD;
EXCITABILITY;
TDCS;
STROKE;
CONSOLIDATION;
PLASTICITY;
SEQUENCE;
ENHANCEMENT;
D O I:
10.1111/ejn.13866
中图分类号:
Q189 [神经科学];
学科分类号:
071006 ;
摘要:
Transcranial direct current stimulation (tDCS) is a neuromodulatory technique which alters motor functions in healthy humans and in neurological patients. Most studies so far investigated the effects of tDCS on mechanisms underlying improvements in upper limb performance. To investigate the effect of anodal tDCS over the lower limb motor cortex (M1) on lower limb motor learning in healthy volunteers, we conducted a randomized, single-blind and sham-controlled study. Thirty-three (25.81 +/- 3.85, 14 female) volunteers were included, and received anodal or sham tDCS over the left M1 (M1-tDCS); 0.0625mA/cm(2) anodal tDCS was applied for 15min during performance of a visuo-motor task (VMT) with the right leg. Motor learning was monitored for performance speed and accuracy based on electromyographic recordings. We also investigated the influence of electrode size and baseline responsivity to transcranial magnetic stimulation (TMS) on the stimulation effects. Relative to baseline measures, only M1-tDCS applied with small electrodes and in volunteers with high baseline sensitivity to TMS significantly improved VMT performance. The computational analysis showed that the small anode was more specific to the targeted leg motor cortex volume when compared to the large anode. We conclude that anodal M1-tDCS modulates VMT performance in healthy subjects. As these effects critically depend on sensitivity to TMS and electrode size, future studies should investigate the effects of intensified tDCS and/or model-based different electrode positions in low-sensitivity TMS individuals.
引用
收藏
页码:779 / 789
页数:11
相关论文