Desktop X-ray tomography for low contrast samples

被引:18
|
作者
Hampai, D. [1 ]
Marchitto, L. [2 ]
Dabagov, S. B. [1 ,3 ,4 ]
Allocca, L. [2 ]
Alfuso, S. [2 ]
Innocenti, L. [5 ]
机构
[1] XLab Frascati, INFN LNF, I-00044 Rome, Italy
[2] CNR, Ist Motori, I-80125 Naples, Italy
[3] RAS, PN Lebedev Phys Inst, Moscow 117901, Russia
[4] Natl Res Nucl Univ, Moscow, Russia
[5] Univ Roma Tor Vergata, Dip Fis, I-00133 Rome, Italy
关键词
Polycapillary optics; Micro tomography; X-ray fast imaging; Fuel injection;
D O I
10.1016/j.nimb.2013.03.051
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Based on the experience in the use of polycapillary optical systems, recently XLab Frascati LNF and IM CNR have been strongly involved in studying the techniques for high resolution X-ray Imaging and micro-tomography that intends in the development of a new imaging instrument to examine low contrast samples complicated by fast developing processes. In order to get the reliable signal to noise ratio, typically available via synchrotron radiation (SR) dedicated X-ray optical devices, for the desktop solutions we have to increase the radiation fluxes from conventional sources. As known, manipulated through polycapillary optics beams result in getting higher fluxes with respect to a pin-hole (with a gain factor of 10(2)-10(3)). Moreover, polycapillary semi lenses can provide low divergent beams comparable by the divergence with synchrotron radiation beams (mrad order). These features make possible the realization of high resolution imaging of low contrast samples in the transmission mode without various algorithmic processes as typically done, for instance, for phase contrast imaging. This work presents the results on X-ray micro tomography for both static biological and fast dynamic samples as well as a possible future development of a polycapillary-based experimental layout for biomedical imaging diagnostics, for the studies in material and environmental sciences, for diagnostics of hi-tech samples, etc. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:264 / 267
页数:4
相关论文
共 50 条
  • [1] Phase contrast based high resolution X-ray desktop tomography
    Perez, A. M. M. M.
    Hampai, D.
    Filippo, A.
    Capitolo, E.
    Poletti, M. E.
    Dabagov, S. B.
    RADIATION PHYSICS AND CHEMISTRY, 2025, 231
  • [2] Desktop X-ray microscopy and microtomography
    Sasov, A
    Van Dyck, D
    JOURNAL OF MICROSCOPY-OXFORD, 1998, 191 : 151 - 158
  • [3] Phase contrast X-ray tomography using synchrotron radiation
    Bonse, U
    Beckmann, F
    Bartscher, M
    Biermann, T
    Busch, F
    Gunnewig, O
    DEVELOPMENTS IN X-RAY TOMOGRAPHY, 1997, 3149 : 108 - 119
  • [4] Statistical Properties of X-Ray Phase-Contrast Tomography
    Chou, Cheng-Ying
    Anastasio, Mark A.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 6648 - +
  • [5] Computed tomography and X-ray fluorescence CT of biological samples
    Pereira, G. R.
    Anjos, M. J.
    Rocha, H. S.
    Faria, P.
    Perez, C. A.
    Lopes, R. T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02) : 951 - 954
  • [6] Phase contrast tomography of the mouse cochlea at microfocus x-ray sources
    Bartels, Matthias
    Hernandez, Victor H.
    Krenkel, Martin
    Moser, Tobias
    Salditt, Tim
    APPLIED PHYSICS LETTERS, 2013, 103 (08)
  • [7] Apparent linear attenuation coefficients in phase contrast X-ray tomography
    Yan, Aimin
    Wu, Xizeng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (16) : 1841 - 1843
  • [8] GDI spray structure analysis by polycapillary X-ray μ-tomography
    Marchitto, L.
    Hampai, D.
    Dabagov, S. B.
    Allocca, L.
    Alfuso, S.
    Polese, C.
    Liedl, A.
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2015, 70 : 15 - 21
  • [9] Desktop x-ray micro-CT instruments
    Sasov, A
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 282 - 290
  • [10] Quantitative phase contrast X-ray tomography of aluminium metal matrix composite
    Agrawal, Ashish K.
    Gupta, Chiradeep
    Singh, Balwant
    Kashyap, Yogesh
    Shukla, Mayank
    APPLIED RADIATION AND ISOTOPES, 2024, 204