Fast mixing condensation nucleus counter: Application to rapid scanning differential mobility analyzer measurements

被引:70
作者
Wang, J
McNeill, VF
Collins, DR
Flagan, RC
机构
[1] CALTECH, Dept Chem Engn, Pasadena, CA 91125 USA
[2] MIT, Cambridge, MA 02139 USA
[3] Texas A&M Univ, College Stn, TX USA
关键词
D O I
10.1080/02786820290038366
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Condensation nucleus counters (CNCs) exhibit slower time response than expected due to mixing effects within the detector. This mixing produces an exponential distribution of delay times with a characteristic mixing time tau(m) that ranges from 0.1 s to 0.9 s for commonly used instruments and limits their usefulness for measuring rapidly changing aerosols. Moreover, when used as detectors in the scanning electrical mobility spectrometer (SEMS; also known as scanning mobility particle sizer, SMPS), CNCs limit the speed with which size distribution measurements can be made. In order to overcome this limitation, a new, fast-response mixing CNC (MCNC) has been developed and characterized. The time response of this new detector and TSI Models 3025 and 3010 CNCs has been measured using a spark source to generate an aerosol pulse. The mixing induced response smearing of this new detector, tau(m), of this instrument is 0.058 s, which is significantly shorter than either of the other instruments tested. Its lower detection limit is about 5 nm diameter. The high aerosol flow rate of the MCNC (0.65 l min(1)), fast time response, and low detection limit make it an ideal detector for SEMS/SMPS measurements. Using this MCNC as a detector for the SEMS, size distribution measurements over the 5 nm to 140 nm range have been made in 3 s with minimal distortion. The size distribution of a coagulation aerosol was effectively recovered by deconvolution with scans as short as 1 s. Uncertainties in the 1 s scans result, in part, from electronics problems in the scanning DMA.
引用
收藏
页码:678 / 689
页数:12
相关论文
共 21 条
[1]   A NEW GENERATOR FOR ULTRAFINE AEROSOLS BELOW 10-NM [J].
BARTZ, H ;
FISSAN, H ;
LIU, BYH .
AEROSOL SCIENCE AND TECHNOLOGY, 1987, 6 (02) :163-171
[2]  
COLLINS DR, 2002, IN PRESS AEROSOL SCI
[3]  
COLLINS DR, 2000, THESIS CALTECH PASAD
[4]   SIMPLE THEORY OF AN IDEALIZED TURBULENT MIXER [J].
CORRSIN, S .
AICHE JOURNAL, 1957, 3 (03) :329-330
[5]   A condensation nucleus counter (CNC) sensitive to singly charged sub-nanometer particles [J].
Gamero-Castaño, M ;
de la Mora, JF .
JOURNAL OF AEROSOL SCIENCE, 2000, 31 (07) :757-772
[6]   CALIBRATION OF A TSI-MODEL-3025 ULTRAFINE CONDENSATION PARTICLE COUNTER [J].
KESTEN, J ;
REINEKING, A ;
PORSTENDORFER, J .
AEROSOL SCIENCE AND TECHNOLOGY, 1991, 15 (02) :107-111
[7]  
Kogan Y., 1960, Rus. J. Phys. Chem, V34, P1240
[8]   DEVELOPMENT OF A MIXING TYPE CONDENSATION NUCLEUS COUNTER [J].
KOUSAKA, Y ;
NIIDA, T ;
OKUYAMA, K ;
TANAKA, H .
JOURNAL OF AEROSOL SCIENCE, 1982, 13 (03) :231-240
[9]   DETERMINATION OF PARTICLE-SIZE DISTRIBUTION OF ULTRA-FINE AEROSOLS USING A DIFFERENTIAL MOBILITY ANALYZER [J].
KOUSAKA, Y ;
OKUYAMA, K ;
ADACHI, M .
AEROSOL SCIENCE AND TECHNOLOGY, 1985, 4 (02) :209-225
[10]   THE PARTICLE-DETECTION EFFICIENCY CURVE OF THE TSI-3010 CPC AS A FUNCTION OF THE TEMPERATURE DIFFERENCE BETWEEN SATURATOR AND CONDENSER [J].
MERTES, S ;
SCHRODER, F ;
WIEDENSOHLER, A .
AEROSOL SCIENCE AND TECHNOLOGY, 1995, 23 (02) :257-261