Smart Electrochemical Oxygen Sensor for Personal Protective Equipment

被引:11
|
作者
Sieber, Arne [1 ]
Enoksson, Peter [2 ]
Krozer, Anatol [1 ]
机构
[1] IMEGO AB, SE-40014 Gothenburg, Sweden
[2] Chalmers Univ, MC2, SE-41296 Gothenburg, Sweden
关键词
Galvanic; oxygen; personal protective equipment; rebreather; sensors; validation; voltammetry;
D O I
10.1109/JSEN.2011.2178593
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Self contained closed circuit rebreathers are life supporting breathing systems, where the exhaled gas is recycled by filtering CO2 and replacing metabolized O-2. For the O-2 injection control galvanic O-2 sensors are used to measure the partial pressure of O-2. A malfunction of the sensors can lead to a gas mixture beyond life supporting limits which is life threatening. Galvanic O-2 sensors are often used in anaesthetic machines in hospitals. Also in this case, a malfunction of the sensors can cause severe injury to a person. It is obvious that such sensors are key elements in life supporting equipment and as such must be designed in order to achieve high functional safety. However these sensors are consuming sensors, and with that, will fail at a certain time. Failure modes include current limitation, non linearity, electrolyte evaporation or leakage, etc. Within this paper a novel low cost read out electronic circuit for galvanic O-2 sensors is presented, which allows not only digital readout, digital temperature compensation, on board storage of calibration and manufacturing data, but also can be used for performing voltammetry cycles to test the Pb anode for exhaustion. First measurements are presented and compared to data from a Solartron SI 1287 impedance analyzer, which is state-of-the-art in electrochemical sensor characterization.
引用
收藏
页码:1846 / 1852
页数:7
相关论文
共 50 条
  • [31] Design and Development of Smart Personal Protective Equipment Vending Machine using Internet of Thing
    Phade, Gayatri
    Tribhuvan, Akash
    Vaidya, Omkar
    Gandhe, Sanjay
    2021 INTERNATIONAL CONFERENCE ON EMERGING SMART COMPUTING AND INFORMATICS (ESCI), 2021, : 252 - 257
  • [32] When to Replace Personal Protective Equipment
    Doan, Daniel R.
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2021, 27 (03) : 7 - +
  • [33] PERSONAL PROTECTIVE EQUIPMENT FOR EMPLOYEES IN INDUSTRY
    不详
    ARCHIVES OF ENVIRONMENTAL HEALTH, 1965, 10 (04): : 663 - 673
  • [34] Definition of personal protective equipment (PPE)
    Burlingame, Byron L.
    AORN JOURNAL, 2016, 104 (01) : 76 - 77
  • [35] Personal protective equipment: Shortage or waste?
    Fram, Dayana Souza
    Escudero, Daniela Vieira da Silva
    Matias, Luciana de Oliveira
    Coelho, Wanderson Eduardo Gomes de Souza
    Antonelli, Thaysa Sobral
    Ferreira, Diogo Boldim
    Medeiros, Eduardo Alexandrino
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2021, 42 (06): : 786 - 787
  • [36] Decontamination and the use of personal protective equipment
    Scarfone, Richard J.
    Sullivan, Frank J.
    Henretig, Fred M.
    PEDIATRIC EMERGENCY CARE, 2006, 22 (06) : 445 - 452
  • [37] SARS and the removal of personal protective equipment
    Puro, V
    Nicastri, E
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2004, 170 (06) : 930 - 930
  • [38] PERSONAL PROTECTIVE EQUIPMENT FOR STEAM APPLICATIONS
    WISEMEN, TR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 14 - CHAS
  • [39] Putting On and Removing Personal Protective Equipment
    Ortega, Rafael
    Bhadelia, Nahid
    Obanor, Osamede
    Cyr, Kyle
    Yu, Priscilla
    McMahon, Maureen
    Gotzmann, Dahlia
    NEW ENGLAND JOURNAL OF MEDICINE, 2015, 372 (12): : e16 - e16
  • [40] Putting On and Removing Personal Protective Equipment
    Grandbastien, Bruno
    Parneix, Pierre
    Berthelot, Philippe
    NEW ENGLAND JOURNAL OF MEDICINE, 2015, 372 (25): : 2464 - 2464