Design and optimization of the readout system for X-ray CCDs

被引:10
作者
Lu Bo [1 ]
Cui Wei-Wei [1 ]
Wang Yu-Sa [1 ]
Zhu Yue [1 ]
Zhang Yi [1 ]
Xu Yu-Peng [1 ]
Chen Yong [1 ]
Huo Jia [1 ]
Li Wei [1 ]
Han Da-Wei [1 ]
Li Mao-Shun [1 ]
Yang Yan-Ji [1 ]
Wang Juan [1 ]
Chen Tian-Xiang [1 ]
Hu Wei [1 ]
Li Cheng-Kui [1 ]
Liu Xiao-Yan [1 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
CCD; X-ray; readout system;
D O I
10.1088/1674-1137/36/9/009
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
A readout system for X-ray CCDs based on an improved architecture is presented; by optimizing several critical circuit blocks along the analog signal chain, the conflict between the readout speed and readout noise is greatly alleviated. Using CCD47-10 as its target CCD, the readout system has achieved 8.6e(-) readout noise and 142 eV FWHM at 5.9 keV Mn K-alpha under a pixel rate of 80 kHz. Also its performance of imaging has been investigated.
引用
收藏
页码:846 / 850
页数:5
相关论文
共 8 条
[1]  
Analog Device Inc, 1999, DAT REC C
[2]  
e2v Inc, 2006, CCD47 10 AIMO BACK I
[3]  
LU Bo, 2012, NUCL ELECT IN PRESS
[4]  
Matsuura D, 2009, THESIS OSAKA U JAPAN
[5]   Fast and flexible CCD-driver system using fast DAC and FPGA [J].
Miyata, E ;
Natsukari, C ;
Akutsu, D ;
Kamazuka, T ;
Nomachi, M ;
Ozaki, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 459 (1-2) :157-164
[6]  
Razavi B., 2002, Design of Analog CMOS Integrated Circuits, V1
[7]   Performance of the XMM EPIC MOS CCD detectors [J].
Short, AD ;
Keay, A ;
Turner, MJL .
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 :13-27
[8]  
Texas Instruments Inc, 2009, DAT