共 12 条
Multisoftware Reproducibility Study of Stress and Rest Myocardial Blood Flow Assessed with 3D Dynamic PET/CT and a 1-Tissue-Compartment Model of 82Rb Kinetics
被引:96
作者:
deKemp, Robert A.
[1
]
Declerck, Jerome
[2
]
Klein, Ran
[1
]
Pan, Xiao-Bo
[2
]
Nakazato, Ryo
[3
]
Tonge, Christine
[4
]
Arumugam, Parthiban
[4
]
Berman, Daniel S.
[3
]
Germano, Guido
[3
]
Beanlands, Rob S.
[1
]
Slomka, Piotr J.
[3
]
机构:
[1] Univ Ottawa, Inst Heart, Natl Cardiac PET Ctr, Ottawa, ON K1Y 4W7, Canada
[2] Siemens Healthcare Mol Imaging, Oxford, England
[3] Cedars Sinai Med Ctr, Los Angeles, CA 90048 USA
[4] NHS Fdn Trust, Cent Manchester Univ Hosp, Manchester, Lancs, England
关键词:
myocardial blood flow quantification;
myocardial perfusion imaging;
rubidium positron emission tomography;
coronary flow reserve;
myocardial perfusion reserve;
POSITRON-EMISSION-TOMOGRAPHY;
PERFUSION;
QUANTIFICATION;
N-13-AMMONIA;
RESERVE;
ACCURACY;
SPECT;
D O I:
10.2967/jnumed.112.112219
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Routine quantification of myocardial blood flow (MBF) requires robust and reproducible processing of dynamic image series. The goal of this study was to evaluate the reproducibility of 3 highly automated software programs commonly used for absolute MBF and flow reserve (stress/rest MBF) assessment with Rb-82 PET imaging. Methods: Dynamic rest and stress Rb-82 PET scans were selected in 30 sequential patient studies performed at 3 separate institutions using 3 different 3-dimensional PET/CT scanners. All 90 scans were processed with 3 different MBF quantification programs, using the same 1-tissue-compartment model. Global (left ventricle) and regional (left anterior descending, left circumflex, and right coronary arteries) MBF and flow reserve were compared among programs using correlation and Bland-Altman analyses. Results: All scans were processed successfully by the 3 programs, with minimal operator interactions. Global and regional correlations of MBF and flow reserve all had an R-2 of at least 0.92. There was no significant difference in flow values at rest (P = 0.68), stress (P = 0.14), or reserve (P = 0.35) among the 3 programs. Bland-Altman coefficients of reproducibility (1.96 x SD) averaged 0.26 for MBF and 0.29 for flow reserve differences among programs. Average pairwise differences were all less than 10%, indicating good reproducibility for MBF quantification. Global and regional SD from the line of perfect agreement averaged 0.15 and 0.17 mL/min/g, respectively, for MBF, compared with 0.22 and 0.26, respectively, for flow reserve. Conclusion: The 1-tissue-compartment model of Rb-82 tracer kinetics is a reproducible method for quantification of MBF and flow reserve with 3-dimensional PET/CT imaging.
引用
收藏
页码:571 / 577
页数:7
相关论文
共 12 条