Single-step CE for miniaturized and easy-to-use system

被引:4
|
作者
Ono, Koichi [1 ]
Kaneda, Shohei [1 ]
Fujii, Teruo [1 ]
机构
[1] Univ Tokyo, Inst Ind Sci, Tokyo 1538505, Japan
关键词
Capillary effect; Capillary stop valve; Field-amplified sample stacking; Microchip capillary electrophoresis; SAMPLE INJECTION; ELECTROPHORESIS; OPTIMIZATION; SEPARATION;
D O I
10.1002/elps.201200365
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We developed a novel single-step capillary electrophoresis (SSCE) scheme for miniaturized and easy to use system by using a microchannel chip, which was made from the hydrophilic material polymethyl methacrylate (PMMA), equipped with a capillary stop valve. Taking the surface tension property of liquids into consideration, the capillary effect was used to introduce liquids and control capillary stop valves in a partial barrier structure in the wall of the microchannel. Through the combined action of stop valves and air vents, both sample plug formation for electrophoresis and sample injection into a separation channel were successfully performed in a single step. To optimize SSCE, different stop valve structures were evaluated using actual microchannel chips and the finite element method with the level set method. A partial barrier structure at the bottom of the channel functioned efficiently as a stop valve. The stability of stop valve was confirmed by a shock test, which was performed by dropping the microchannel chip to a floor. Sample plug deformation could be reduced by minimizing the size of the side partial barrier. By dissolving hydroxyl ethyl cellulose and using it as the sample solution, the EOF and adsorption of the sample into the PMMA microchannel were successfully reduced. Using this method, a 100-bp DNA ladder was concentrated; good separation was observed within 1 min. At a separation length of 5 mm, the signal was approximately 20-fold higher than a signal of original sample solution by field-amplified sample stacking effect. All operations, including liquid introduction and sample separation, can be completed within 2 min by using the SSCE scheme.
引用
收藏
页码:903 / 910
页数:8
相关论文
共 50 条
  • [1] A MINIATURIZED SINGLE-STEP METHOD OF CELL CLONING
    BISHOP, CE
    JOURNAL OF IMMUNOLOGICAL METHODS, 1981, 46 (01) : 47 - 51
  • [2] An easy-to-use damage control system for warships
    Ghesquiere, O
    ELEVENTH SHIP CONTROL SYSTEMS SYMPOSIUM, VOL 1, 1997, : 445 - 455
  • [3] The study of an easy-to-use DBR and BM system
    Tseng, MF
    Wu, HH
    INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 2006, 44 (08) : 1449 - 1478
  • [4] EASY-TO-USE MOSSBAUER SYSTEM WITH SIMULTANEOUS DISPLAY
    WALLINGFORD, E
    BORDELEAU, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (06): : 1253 - 1256
  • [5] AN EASY-TO-USE CHARTMAKER
    SEAVER, M
    DEA, RW
    SIMMS, RJ
    HEWLETT-PACKARD JOURNAL, 1983, 34 (11): : 10 - 12
  • [6] Easy-to-use presetter
    不详
    MANUFACTURING ENGINEERING, 1999, 123 (01): : 36 - 36
  • [7] NAPROS - A SEMIAUTOMATIC EASY-TO-USE ANESTHESIA PROTOCOLL SYSTEM
    WINTER, D
    OSSWALD, PM
    ANAESTHESIST, 1986, 35 (04): : 261 - 267
  • [8] An Affordable and Easy-to-Use Interferometer with a Dedicated Acquisition System
    Merzouk, Walid-Adel
    Cagneau, Barthelemy
    Hilouanc, Khalid
    Chassagnc, Luc
    Gardillou, Florent
    2016 IEEE SENSORS, 2016,
  • [10] An Easy Single-Step Synthesis of Platinum Nanoparticles Embedded in Carbon
    Shanmugam, Sangaraju
    Simon, Ulrich