Effects of tree shading and transpiration on building cooling energy use

被引:99
作者
Hsieh, Chun-Ming [1 ]
Li, Juan-Juan [2 ]
Zhang, Liman [3 ]
Schwegler, Ben [4 ]
机构
[1] Tongji Univ, Coll Architecture & Urban Planning, Big Data & Urban Analyt LAB, Dept Urban Planning, 1239 Siping Rd, Shanghai 200092, Peoples R China
[2] Walt Disney Co China Ltd, Disney Res CHINA, 624 West Jianguo Rd, Shanghai 200031, Peoples R China
[3] Tongji Univ, Coll Architecture & Urban Planning, Dept Landscape Architecture, 1239 Siping Rd, Shanghai 200092, Peoples R China
[4] Stanford Univ, Dept Civil & Environm Engn, Stanford, CA 94305 USA
关键词
Building cooling energy; EnergyPlus; Microclimate; Trees shading; Transpiration; URBAN HEAT-ISLAND; HIGHRISE RESIDENTIAL BUILDINGS; WIND ENVIRONMENT; MITIGATION; CONSUMPTION; DESIGN; IMPACT; PERFORMANCE; OUTDOOR; MICROCLIMATE;
D O I
10.1016/j.enbuild.2017.10.045
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Building cooling energy use is regarded as the hot topic of building research due to its increasing trend at a rate proportional to the total direct energy use in urban areas nowadays. Urban greening as an effective countermeasure in reducing building cooling load has been attracting close attention although there is a shortage of quantitative measures for applying the general idea to a specific site or building. This study addresses this problem. The cooling effect of trees around buildings and the influence of tree characteristics on building cooling load reduction was quantified using microclimate field measurements and sap flow rate of trees. By integrating approaches of field measurements of microclimate and tree characteristics into EnergyPlus simulation of building energy use, the cooling effects of trees due to both shading and transpiration on buildings were quantified and discussed. Four scenarios were developed based on different tree characteristics for quantifying the influence of trees oh saving of building energy use: Scenario 1 with treeless condition, Scenario 2 with existing trees condition in a case of Nanjing City, Scenario 3 with more tree shading condition, and Scenario 4 with more tree transpiration condition. The simulation results showed that compared to Scenario 1, Scenario 2 can reduce building energy use by 10.3% due to the benefits from existing trees shading and transpiration. More shading in Scenario 3 and a higher transpiration rate in Scenario 4 can reduce building energy use by 15.2% and 12.4%, respectively in comparison to that in Scenario 1. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:382 / 397
页数:16
相关论文
共 64 条
[11]   Energy savings in buildings or UHI mitigation? Comparison between green roofs and cool roofs [J].
Costanzo, V. ;
Evola, G. ;
Marletta, L. .
ENERGY AND BUILDINGS, 2016, 114 :247-255
[12]   Keeping California cool: Recent cool community developments [J].
Gilbert, Haley ;
Mandel, Benjamin H. ;
Levinson, Ronnen .
ENERGY AND BUILDINGS, 2016, 114 :20-26
[13]   Modelling and calibration of a high-mass historic building for reducing the prebound effect in energy assessment [J].
Giuliani, Marco ;
Henze, Gregor P. ;
Florita, Anthony R. .
ENERGY AND BUILDINGS, 2016, 116 :434-448
[14]  
Granier A, 2000, AGR FOREST METEOROL, V100, P291, DOI [10.1016/S0168-1923(99)00151-3, 10.1016/0168-1923(95)02252-X]
[15]   EVALUATION OF TRANSPIRATION IN A DOUGLAS-FIR STAND BY MEANS OF SAP FLOW MEASUREMENTS [J].
GRANIER, A .
TREE PHYSIOLOGY, 1987, 3 (04) :309-319
[16]   Seasonal variations in the cooling effect of urban green areas on surrounding urban areas [J].
Hamada, Shuko ;
Ohta, Takeshi .
URBAN FORESTRY & URBAN GREENING, 2010, 9 (01) :15-24
[17]   Daily energy consumption signatures and control charts for air-conditioned buildings [J].
Hitchin, Roger ;
Knight, Ian .
ENERGY AND BUILDINGS, 2016, 112 :101-109
[18]   Quantifying cooling effects of facade greening: Shading, transpiration and insulation [J].
Hoelscher, Marie-Therese ;
Nehls, Thomas ;
Jaenicke, Britta ;
Wessolek, Gerd .
ENERGY AND BUILDINGS, 2016, 114 :283-290
[19]   Numerical studies of the outdoor wind environment and thermal comfort at pedestrian level in housing blocks with different building layout patterns and trees arrangement [J].
Hong, Bo ;
Lin, Borong .
RENEWABLE ENERGY, 2015, 73 :18-27
[20]   The feedback of heat rejection to air conditioning load during the nighttime in subtropical climate [J].
Hsieh, Chun-Ming ;
Aramaki, Toshiya ;
Hanaki, Keisuke .
ENERGY AND BUILDINGS, 2007, 39 (11) :1175-1182