Direct aperture optimization for FLEC-based MERT and its application in mixed beam radiotherapy

被引:18
作者
Alexander, Andrew [1 ]
Soisson, Emilie [1 ]
Renaud, Marc-Andre [1 ]
Seuntjens, Jan [1 ]
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ H3G 1A4, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
modulated electron radiotherapy; Monte Carlo; IMRT; electron-photon inverse treatment planning; MODULATED ELECTRON RADIOTHERAPY; MULTI-LEAF COLLIMATOR; TREATMENT HEAD DESIGN; MONTE-CARLO; RADIATION-THERAPY; PHOTON BEAMS; DOSIMETRIC VERIFICATION; PROTON THERAPY; BREAST-CANCER; ARC THERAPY;
D O I
10.1118/1.4736423
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Despite promising research in modulated electron radiotherapy (MERT), an applicator to produce modulated electron beams and associated treatment planning software is still not commercially available. This work investigated an optimization process in treatment planning for the McGill few leaf electron collimator (FLEC) MERT delivery device. In addition, the possibility of combining MERT with photon fields was examined to investigate mixed beam radiotherapy. Methods: A FLEC direct aperture optimization (DAO) method, in which FLEC apertures and weights were iteratively optimized was created. The authors evaluated the performance of DAO against our previous technique for generating FLEC plans and with commercially available photon beam optimization algorithms using a basic target and organ at risk geometry. The authors applied the DAO technique on a sarcoma treatment to evaluate clinical parameters. Finally, the authors examined the merit of mixing the DAO generated FLEC electron fields with photon fields to improve the dosimetry of the sarcoma treatment. Results: In relation to the alternative plans, the DAO generated sarcoma MERT plan was competitive in its ability to reduce the dose to OAR but weaker in its ability to highly conform the dose to the target volume. The addition of photon fields improved the quality of the MERT plan in terms of OAR sparing and target conformality. Conclusions: The DAO approach yielded deliverable FLEC-based MERT plans with a limited number of fields. The approach combined with photon optimization added flexibility, where the mutual benefits of each radiation type was used in unison to improve plan quality. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4736423]
引用
收藏
页码:4820 / 4831
页数:12
相关论文
共 62 条
  • [1] Monte Carlo based modulated electron beam treatment planning using a few-leaf electron collimator - feasibility study
    Al-Yahya, K
    Hristov, D
    Verhaegen, F
    Seuntjens, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (05) : 847 - 857
  • [2] Energy modulated electron therapy using a few leaf electron collimator in combination with IMRT and 3D-CRT: Monte Carlo-based planning and dosimetric evaluation
    Al-Yahya, K
    Schwartz, M
    Shenouda, G
    Verhaegen, F
    Freeman, C
    Seuntjens, J
    [J]. MEDICAL PHYSICS, 2005, 32 (09) : 2976 - 2986
  • [3] Design and dosimetry of a few leaf electron collimator for energy modulated electron therapy
    Al-Yahya, Khalid
    Verhaegen, Frank
    Seuntjens, Jan
    [J]. MEDICAL PHYSICS, 2007, 34 (12) : 4782 - 4791
  • [4] MMCTP: a radiotherapy research environment for Monte Carlo and patient-specific treatment planning
    Alexander, A.
    DeBlois, F.
    Stroian, G.
    Al-Yahya, K.
    Heath, E.
    Seuntjens, J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (13) : N297 - N308
  • [5] All-Inclusive DOSXYZnrc Source for Monte Carlo QA of External Beam Radiotherapy
    Alexander, A.
    Renaud, M.
    Seuntjens, J.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3382 - +
  • [6] Comparison of modulated electron radiotherapy to conventional electron boost irradiation and volumetric modulated photon arc therapy for treatment of tumour bed boost in breast cancer
    Alexander, Andrew
    Soisson, Emilie
    Hijal, Tarek
    Sarfehnia, Arman
    Seuntjens, Jan
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 100 (02) : 253 - 258
  • [7] Toward automatic field selection and planning using Monte Carlo-based direct aperture optimization in modulated electron radiotherapy
    Alexander, Andrew
    DeBlois, Francois
    Seuntjens, Jan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16) : 4563 - 4576
  • [8] Optimal electron and combined electron and photon therapy in the phase space of complication-free cure
    Åsell, M
    Hyödynmaa, S
    Söderström, S
    Brahme, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (01) : 235 - 252
  • [9] Multileaf collimation of electrons-clinical effects on electron energy modulation and mixed beam therapy depending on treatment head design
    Blomquist, M
    Karlsson, MG
    Zackrisson, B
    Karlsson, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (07) : 1013 - 1024
  • [10] Chan MF, 2006, C P IEEE ENG MED BIO, V1, P152