The C0-C2 axial rotation test: normal values, intra- and inter-rater reliability and correlation with the flexion rotation test in normal subjects

被引:18
作者
Satpute, Kiran [1 ]
Nalband, Sadaf [2 ]
Hall, Toby [3 ,4 ]
机构
[1] Smt Kashibai Navale Coll Physiotherapy, Dept Kinesiotherapy & Phys Diag, Dept Musculoskeletal Physiotherapy, Pune 411041, Maharashtra, India
[2] Smt Kashibai Navale Coll Physiotherapy, Pune, Maharashtra, India
[3] Curtin Univ, Sch Physiotherapy & Exercise Sci, Perth, WA, Australia
[4] Univ Western Australia, Fac Hlth & Med Sci, Perth, WA, Australia
关键词
Upper cervical spine rotation; flexion-rotation test; goniometer; PHYSICAL-EXAMINATION TESTS; CERVICAL-SPINE; CONCURRENT VALIDITY; DIAGNOSTIC VALIDITY; NECK PAIN; RANGE; MOTION; HEADACHE; POSITION; APP;
D O I
10.1080/10669817.2018.1533195
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: Impairment in upper cervical spine mobility is associated with cervicogenic headache severity and disability. Measures of such mobility include the flexion-rotation test (FRT), which requires full cervical flexion and may be influenced by lower cervical spine dysfunction. The C0-C2 axial rotation test also evaluates upper cervical mobility but normal values and reliability have not been reported. Our objective is to determine normal values, and intra-rater and inter-rater reliability of the C0-C2 axial rotation test. Methods: Two therapists independently evaluated the FRT and C0-C2 axial rotation test with an iPhone compass application on 32 asymptomatic subjects with mean age 40.53 (SD 11.64) years on two occasions. Measurement procedures were standardized; and order of testing randomized. Results: For the FRT and C0-C2 axial rotation test reliability was high (ICC > 0.88). For rater one, Mean range to the left during the FRT and C0-C2 axial rotation test was 45.0 degrees (6.04) and 14.43 degrees (2.94), respectively, while range to the right was 44.6 degrees (6.57) and 15.44 degrees (2.68). For the FRT and C0-C2 axial rotation test the standard error of measurement was at most 2 degrees, while the minimum detectable change was at most 4 degrees. A strong positive correlation exists between the FRT and CO-C2 axial rotation test (r = 0.84, P < 0.01). Discussion: The range recorded during the C0-C2 axial rotation test and FRT have high levels of reliability when evaluated using an iPhone. The strong correlation between the FRT and C0-C2 axial rotation test indicate that both may be measuring similar constructs, but each test needs to be referenced to normal values.
引用
收藏
页码:92 / 98
页数:7
相关论文
共 27 条
[1]   Measuring range of active cervical rotation in a position of full head flexion using the 3D Fastrak measurement system: an intra-tester reliability study [J].
Amiri, M ;
Jull, G ;
Bullock-Saxton, J .
MANUAL THERAPY, 2003, 8 (03) :176-179
[2]   Extension and flexion in the upper cervical spine in neck pain patients [J].
Ernst, Markus J. ;
Crawford, Rebecca J. ;
Schelldorfer, Sarah ;
Rausch-Osthoff, Anne-Kathrin ;
Barbero, Marco ;
Kool, Jan ;
Bauer, Christoph M. .
MANUAL THERAPY, 2015, 20 (04) :547-552
[3]   Intrarater Reliability of CROM Measurement of Cervical Spine Active Range of Motion in Persons With and Without Neck Pain [J].
Fletcher, James P. ;
Bandy, William D. .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2008, 38 (10) :640-645
[4]   Reliability and concurrent validity of the iPhone® Compass application to measure thoracic rotation range of motion (ROM) in healthy participants [J].
Furness, James ;
Schram, Ben ;
Cox, Alistair J. ;
Anderson, Sarah L. ;
Keogh, Justin .
PEERJ, 2018, 6
[5]   Does altered mandibular position and dental occlusion influence upper cervical movement: A cross-sectional study in asymptomatic people [J].
Grondin, Francis ;
Hall, Toby ;
von Piekartz, Harry .
MUSCULOSKELETAL SCIENCE AND PRACTICE, 2017, 27 :85-90
[6]   Upper cervical range of motion is impaired in patients with temporomandibular disorders [J].
Grondin, Francis ;
Hall, Toby ;
Laurentjoye, Mathieu ;
Ella, Bruna .
CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 2015, 33 (02) :91-99
[7]   Reliability and Criterion Validity of the Smartphone Inclinometer Application to Quantify Cervical Spine Mobility [J].
Guidetti, Laura ;
Placentino, Umberto ;
Baldari, Carlo .
CLINICAL SPINE SURGERY, 2017, 30 (10) :E1359-E1366
[8]   The flexion-rotation test and active cervical mobility - A comparative measurement study in cervicogenic headache [J].
Hall, T ;
Robinson, K .
MANUAL THERAPY, 2004, 9 (04) :197-202
[9]   Efficacy of a C1-C2 self-sustained natural apophyseal glide (SNAG) in the management of cervicogenic headache [J].
Hall, Toby ;
Chan, Ho Tak ;
Christensen, Lene ;
Odenthal, Britta ;
Wells, Cherie ;
Robinson, Kim .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2007, 37 (03) :100-107
[10]   The influence of lower cervical joint pain on range of motion and interpretation of the flexion-rotation test [J].
Hall, Toby ;
Briffa, Kathy ;
Hopper, Diana .
JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2010, 18 (03) :126-131