Long-term assessment after implantation of the Vibrant Soundbridge device

被引:70
作者
Schmuziger, N [1 ]
Schimmann, F
àWengen, D
Patscheke, J
Probst, R
机构
[1] Kantonsspital Aarau, HNO Klin, Dept Otorhinolaryngol, CH-5001 Aarau, Switzerland
[2] Univ Basel Hosp, Dept Otorhinolaryngol, CH-4031 Basel, Switzerland
[3] Birshof Hosp, Munchenstein, Switzerland
关键词
benefit; hearing aid; long-term assessment; middle ear; residual hearing; satisfaction; Vibrant Soundbridge;
D O I
10.1097/01.mao.0000199754.51815.70
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To present long-term results with a semi-implantable middle ear implant, the Vibrant Soundbridge (VSB), and analyze pre- and post-operative results of audiologic tests. Study Design: Retrospective chart review with additional patient interview and audiologic testing. Setting: One tertiary referral center. Subjects: Twenty patients who met the selection criteria of the manufacturer were evaluated at least two years after implantation. Interventions: Monaural Implantation of the VSB in 20 patients. in two of these 20 patients implantation of the second ear in a second stage. Results: Assessment of benefit and satisfaction using the standardized International Outcome Inventory for Hearing Aids, the Glasgow Benefit Inventory, and Visual Analogue Scales in all patients. Fifteen patients agreed to undergo audiologic testing at follow-Lip including pure-tone- and speech audiometry in silence and noise. The majority of patients (13/20) reported to be satisfied or very satisfied with the VSB. Aided speech perception was comparable between the VSB and the hearing aid preoperatively. When compared to the preoperative audiograms, residual hearing from 0.5-4 kHz was significantly worse in the operated ear with 8 dB (Wilcoxon signed rank test p < 0.001) but only 2.6 dB in the non-operated ear (Wilcoxon signed rank test, p > 0.05). Major surgical complications did not Occur. Permanent alteration in taste occurred in three patients and revision surgery was necessary in another three patients. Conclusion: Satisfaction with the VSB was not Superior to conventional hearing aids in Subjective and in audiometric terms. Because of its impact on residual hearing and the requirement of implantation middle ear surgery, implantation of the VSB should be limited to patients with relevant side effects of hearing aids, e.g., severe chronic otitis externa.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 20 条
[1]   Translations of the International Outcome Inventory for Hearing Aids (IOI-HA) [J].
Cox, RM ;
Stephens, D ;
Kramer, SE .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2002, 41 (01) :3-26
[2]  
COX RM, 2003, J AM ACAD AUDIOL, V8, P403
[3]   Clinical experience with the vibrant soundbridge implant device [J].
Fisch, U ;
Cremers, CWRJ ;
Lenarz, T ;
Weber, B ;
Babighian, G ;
Uziel, AS ;
Proops, DW ;
O'Connor, AF ;
Charachon, R ;
Helms, J ;
Fraysse, B .
OTOLOGY & NEUROTOLOGY, 2001, 22 (06) :962-972
[4]   A multicenter study of the vibrant soundbridge middle ear implant:: Early clinical results and experience [J].
Fraysse, B ;
Lavieille, JP ;
Schmerber, S ;
Enée, V ;
Truy, E ;
Vincent, C ;
Vaneecloo, FM ;
Sterkers, O .
OTOLOGY & NEUROTOLOGY, 2001, 22 (06) :952-961
[5]   Functional gain of already implanted hearing devices in patients with sensorineural hearing loss of varied origin and extent: Berlin experience [J].
Junker, R ;
Gross, M ;
Todt, I ;
Ernst, A .
OTOLOGY & NEUROTOLOGY, 2002, 23 (04) :452-456
[6]   Vibrant Soundbridge implant: A new hearing prosthesis for patients with sensorineural hearing loss; Part 1 - Principle of the Soundbridge system and initial clinical results. [J].
Lenarz, T ;
Weber, BP ;
Mack, KF ;
Battmer, RD ;
Gnadeberg, D .
LARYNGO-RHINO-OTOLOGIE, 1998, 77 (05) :247-255
[7]   Vibrant soundbridge implant: A new hearing prosthesis for patients with sensorineural hearing loss. part 2: Audiological results. [J].
Lenarz, T ;
Weber, BP ;
Issing, PR ;
Gnadeberg, D ;
Arnbjornsen, K ;
Mack, KF ;
Winter, M .
LARYNGO-RHINO-OTOLOGIE, 2001, 80 (07) :370-380
[8]   Phase III clinical trial results with the Vibrant Soundbridge implantable middle ear hearing device: A prospective controlled multicenter study [J].
Luetje, CM ;
Brackman, D ;
Balkany, TJ ;
Maw, J ;
Baker, RS ;
Kelsall, D ;
Backous, D ;
Miyamoto, R ;
Parisier, S ;
Arts, A .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2002, 126 (02) :97-107
[9]   Bone-anchored hearing aid: Comparison of benefit by patient subgroups [J].
McLarnon, CM ;
Davison, T ;
Johnson, IJM .
LARYNGOSCOPE, 2004, 114 (05) :942-944
[10]   The effects of mass loading the ossicles with a floating mass transducer on middle ear transfer function [J].
Needham, AJ ;
Jiang, D ;
Bibas, A ;
Jeronimidis, G ;
O'Connor, AF .
OTOLOGY & NEUROTOLOGY, 2005, 26 (02) :218-224