Rehabilitation of edentulous posterior atrophic mandible: inferior alveolar nerve lateralization by piezotome and immediate implant placement

被引:32
作者
Fernandez Diaz, J. O.
Naval Gias, L.
机构
[1] Department of Oral and Maxillofacial Surgery, University Hospital la Princesa, 28223 Madrid, C/Vista Alegre 1, Q
关键词
inferior alveolar nerve lateralization; ultrasonic bone cutting; piezotome; posterior mandibular atrophy; RIDGE AUGMENTATION; AUTOGENOUS BONE; TITANIUM MESH; TRANSPOSITION; PIEZOSURGERY; CONJUNCTION;
D O I
10.1016/j.ijom.2012.10.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The height and consistency of the bone tissue located above the inferior alveolar nerve (IAN) represents an important challenge when a patient's atrophied posterior mandible is rehabilitated with an osseointegrated implant. Usually, the surgical reconstruction of atrophic ridges is performed using several different techniques. The purpose of this study is to demonstrate the effectiveness and safety of the inferior alveolar nerve lateralization (IANL) technique performed with ultrasonic cutting technology (piezotome). To demonstrate this, 38 osseointegrated implants (11-15 mm in length) were performed during 19 procedures on 15 different patients. After 8 weeks, 14 of those 15 patients (18 of 19 sites: 94.73%) showed normal IAN function. The implant success rate was 97.36%.
引用
收藏
页码:521 / 526
页数:6
相关论文
共 21 条
[1]  
Beirne R, 1991, ORAL MAXILLOFAC SURG, V3, P993
[2]   Long-term stability of osseointegrated implants in bone regenerated with the membrane technique - 5-year results of a prospective study with 12 implants [J].
Buser, D ;
Dula, K ;
Lang, NP ;
Nyman, S .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (02) :175-183
[3]  
Chiapasco M, 2004, INT J ORAL MAX IMPL, V19, P399
[4]  
Dahlin C, 1991, Int J Periodontics Restorative Dent, V11, P273
[5]   Bone lid technique with piezosurgery to preserve inferior alveolar nerve [J].
Degerliyurt, Kagan ;
Akar, Volkan ;
Denizci, Senem ;
Yucel, Ergun .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (06) :E1-E5
[6]   Piezosurgery®:: an ultrasound device for cutting bone and its use and limitations in maxillofacial surgery [J].
Eggers, G ;
Klein, J ;
Blank, J ;
Hassfeld, S .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2004, 42 (05) :451-453
[7]  
Ferrigno N, 2005, INT J ORAL MAX IMPL, V20, P610
[8]  
Haers PE, 1994, ORAL MAXILLOFAC SURG, V7, P707
[9]   Neurosensory function following mandibular nerve lateralization for placement of implants [J].
Hashemi, H. M. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 39 (05) :452-456
[10]  
Kan JYK, 1997, INT J ORAL MAX IMPL, V12, P463