Early osseointegration driven by the surface chemistry and wettability of dental implants

被引:106
|
作者
Sartoretto, Suelen Cristina [1 ]
Neves Novellino Alves, Adriana Terezinha [1 ]
Britto Resende, Rodrigo Figueiredo [1 ]
Calasans-Maia, Jose [2 ]
Granjeiro, Jose Mauro [3 ,4 ]
Calasans-Maia, Monica Diuana [4 ]
机构
[1] Univ Fed Fluminense, Grad Program Dent, Niteroi, RJ, Brazil
[2] Univ Fed Fluminense, Dept Orthodont, Niteroi, RJ, Brazil
[3] Natl Inst Metrol Qual & Technol, Duque De Caxias, RJ, Brazil
[4] Univ Fed Fluminense, Sch Dent, Dent Clin Res Ctr, Niteroi, RJ, Brazil
关键词
Dental implants; Surface properties; Wettability; Osseointegration; Rabbits; HISTOMORPHOMETRIC EVALUATION; BONE APPOSITION; TITANIUM; INTEGRATION; ADSORPTION; BEHAVIOR; ENERGY;
D O I
10.1590/1678-775720140483
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The objective of this study was to investigate the impact of two different commercially available dental implants on osseointegration. The surfaces were: sandblasting and acid etching (Group 1) and sandblasting and acid etching, then maintained in an isotonic solution of 0.9% sodium chloride (Group 2). Material and Methods: X-ray photoelectron spectroscopy (XPS) was employed for surface chemistry analysis. Surface morphology and topography was investigated by scanning electron microscopy (SEM) and confocal microscopy (CM), respectively. Contact angle analysis (CAA) was employed for wetting evaluation. Bone-implant-contact (BIC) and bone area fraction occupied (BAFO) analysis were performed on thin sections (30 mu m) 14 and 28 days after the installation of 10 implants from each group (n=20) in rabbits' tibias. Statistical analysis was performed by ANOVA at the 95% level of significance considering implantation time and implant surface as independent variables. Results: Group 2 showed 3-fold less carbon on the surface and a markedly enhanced hydrophilicity compared to Group 1 but a similar surface roughness (p>0.05). BIC and BAFO levels in Group 2 at 14 days were similar to those in Group 1 at 28 days. After 28 days of installation, BIC and BAFO measurements of Group 2 were approximately 1.5-fold greater than in Group 1 (p<0.05). Conclusion: The surface chemistry and wettability implants of Group 2 accelerate osseointegration and increase the area of the bone-to-implant interface when compared to those of Group 1.
引用
收藏
页码:279 / 287
页数:9
相关论文
共 50 条
  • [11] Biocompatibility and osseointegration of nanostructured titanium dental implants in minipigs
    Hoornaert, Alain
    Vidal, Luciano
    Besnier, Romain
    Morlock, Jean-Francois
    Louarn, Guy
    Layrolle, Pierre
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (06) : 526 - 535
  • [12] Osseointegration of Zirconia Implants with Different Surface Characteristics: An Evaluation in Rabbits
    Hoffmann, Oliver
    Angelov, Nikola
    Zafiropoulos, Gregory-George
    Andreana, Sebastiano
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (02) : 352 - 358
  • [13] Surface Roughness of Dental Implant and Osseointegration
    Matos, Geraldo Roberto Martins
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2021, 20 (01) : 1 - 4
  • [14] The effect of cigarette smoking on early osseointegration of dental implants: a prospective controlled study
    Bezerra Ferreira, Jose Divino
    Rodrigues, Jose Augusto
    Piattelli, Adriano
    Iezzi, Giovanna
    Gehrke, Sergio Alexandre
    Shibli, Jamil Awad
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (09) : 1123 - 1128
  • [15] Influence of obesity on osseointegration of implants with different surface treatments: A preclinical study
    Silva, Bruno Luis Graciliano
    Sanchez-Puetate, Julio Cesar
    Pinotti, Felipe Eduardo
    Marcantonio, Camila Chierici
    Pedroso, Gabriel Gimenez
    Marcantonio Junior, Elcio
    Marcantonio, Rosemary Adriana Chierici
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2023, 25 (05) : 919 - 928
  • [16] Effects of selected factors on the osseointegration of dental implants
    Koszuta, Piotr
    Grafka, Agnieszka
    Koszuta, Agnieszka
    Lopucki, Maciej
    Szymanska, Jolanta
    MENOPAUSE REVIEW-PRZEGLAD MENOPAUZALNY, 2015, 14 (03): : 184 - 187
  • [17] Significance of primary stability for osseointegration of dental implants
    Lioubavina-Hack, N
    Lang, NP
    Karring, T
    CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (03) : 244 - 250
  • [18] Relevant Aspects of Titanium and Zirconia Dental Implants for Their Fatigue and Osseointegration Behaviors
    Aragoneses, Javier
    Lopez Valverde, Nansi
    Fernandez-Dominguez, Manuel
    Mena-Alvarez, Jesus
    Rodriguez, Cinthia
    Gil, Javier
    Manuel Aragoneses, Juan
    MATERIALS, 2022, 15 (11)
  • [19] In-vivo study of ultrafine-grained CP-Ti dental implants surface modified by SLActive with excellent wettability
    Masrouri, Milad
    Faraji, Ghader
    Pedram, M. Sepehr
    Sadrkhah, Mohammadreza
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2020, 102
  • [20] Construction of functional surfaces for dental implants to enhance osseointegration
    Wang, Zhenshi
    Wang, Jiaolong
    Wu, Runfa
    Wei, Junchao
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11