Arrival time parametric imaging: A new ultrasound technique for quantifying perfusion of kidney grafts

被引:28
作者
Fischer, T. [1 ]
Fillmonow, S.
Rudolph, J.
Morgera, S. [2 ]
Budde, K. [2 ]
Slowinski, T. [2 ]
Ebeling, V. [3 ]
Taymoorian, K. [3 ]
Giessing, M. [3 ]
Thomas, A. [4 ]
机构
[1] Charite, Inst Radiol, Dept Radiol, D-10098 Berlin, Germany
[2] Charite, Dept Nephrol, D-10098 Berlin, Germany
[3] Charite, Dept Urol, D-10098 Berlin, Germany
[4] Charite, Dept Gynaecol, D-10098 Berlin, Germany
来源
ULTRASCHALL IN DER MEDIZIN | 2008年 / 29卷 / 04期
关键词
ultrasound; kidney; contrast medium; parametric imaging;
D O I
10.1055/s-2006-927269
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose: Evaluation of a new standardised ultrasound (US) technique for diagnosis of acute rejection of kidney grafts. Materials and Methods: Twenty-two kidney recipients underwent US examination following administration of 1.6 ml US contrast medium (USCM, SonoVue (TM)) 6 days after kidney transplantation. The examinations were performed with the Aplio US system (Toshiba (TM)). The difference in time to the first increase in signal intensity between the renal artery and the renal cortex was determined. Subsequently, the temporal course of contrast enhancement in the area of the renal artery following the first peak was recorded over 10 sec and depicted in colour using a Windows-based software. The resulting colour-time-images were evaluated by three readers who rated the images on an analogue scale from 1 (normal) to 5 (abnormal). Results: 12 of the 22 patients had an uneventful clinical course. US demonstrated rapid inflow of the USCM into the renal cortex. The calculated time difference was 1.0 +/- 0.4 sec. The score assigned to the parametric images was 1.7 +/- 0.8. 8 of the 22 patients underwent biopsy and showed histologically proven rejection. The time difference in the rejection group was twice as high as in the normal group (2.2 +/- 0.7 sec, p < 0.05). The scores were in the abnormal range (3.7 +/- 1.6, p < 0.05). Two patients with perirenal haematoma also had high scores, without rejection. Conclusions: Acute rejection and perirenal haematoma are associated with a delayed signal increase in the renal cortex. This information can be provided with a single image with standardised colour display of the temporal course of USCM inflow.
引用
收藏
页码:418 / 423
页数:6
相关论文
共 22 条
[1]   Which continuous US scanning mode is optimal for the detection of vascularity in liver lesions when enhanced with a second generation contrast agent? [J].
Basilico, R ;
Blomley, MJK ;
Harvey, CJ ;
Filippone, A ;
Heckemann, RA ;
Eckersley, RJ ;
Cosgrove, DO .
EUROPEAN JOURNAL OF RADIOLOGY, 2002, 41 (03) :184-191
[2]   Clinical safety of SonoVue™, a new contrast agent for ultrasound imaging, in healthy volunteers and in patients with chronic obstructive pulmonary disease [J].
Bokor, D ;
Chambers, JB ;
Rees, PJ ;
Mant, TGK ;
Luzzani, F ;
Spinazzi, A .
INVESTIGATIVE RADIOLOGY, 2001, 36 (02) :104-109
[3]   Contrast superharmonic imaging: A feasibility study [J].
Bouakaz, A ;
Krenning, BJ ;
Vletter, WB ;
ten Cate, FJ ;
De Jong, N .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (04) :547-553
[4]   Doppler sonographic estimation of normal values for flow velocity and resistance indices in renal arteries of healthy infants [J].
Deeg, KH ;
Wörle, K ;
Wolf, A .
ULTRASCHALL IN DER MEDIZIN, 2003, 24 (05) :312-322
[5]   3D real time contrast enhanced ultrasonography, an new technique [J].
Dietrich, CF .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (02) :160-163
[6]   Early postoperative ultrasound of kidney transplants:: Evaluation of contrast medium dynamics using time-intensity curves [J].
Fischer, T ;
Mühler, M ;
Kröncke, TJ ;
Lembcke, A ;
Rudolph, J ;
Diekmann, F ;
Ebeling, V ;
Thomas, A ;
Greis, C ;
Hamm, B ;
Filimonow, S .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (04) :472-477
[7]   Comparison of standard and second harmonic B-mode sonography in the detection of segmental renal infarction with sonographic contrast in a rabbit model [J].
Girard, MS ;
Mattrey, RF ;
Baker, KG ;
Peterson, T ;
Deiranieh, LH ;
Steinbach, GC .
JOURNAL OF ULTRASOUND IN MEDICINE, 2000, 19 (03) :185-192
[8]  
Hohmann J, 2003, ROFO-FORTSCHR RONTG, V175, P835
[9]   Clinical correlation of acute rejection according to Banff classification in renal transplantation [J].
Lorriaux, C ;
Noble, CP ;
Dijoud, F ;
Cahen, R ;
Touraine, JL ;
MacGregor, B .
TRANSPLANTATION PROCEEDINGS, 2000, 32 (02) :443-444
[10]   Duplex Doppler analysis of interlobular arteries in transplanted kidneys [J].
Martinoli, C ;
Bertolotto, M ;
Crespi, G ;
Pretolesi, F ;
Valle, M ;
Derchi, LE .
EUROPEAN RADIOLOGY, 1998, 8 (05) :765-769