Effect of surface roughness on performance of magnetoelastic biosensors for the detection of Escherichia coli

被引:21
作者
Possan, A. L. [1 ]
Menti, C. [2 ]
Beltrami, M. [1 ]
Santos, A. D. [3 ]
Roesch-Ely, M. [2 ]
Missell, F. P. [1 ]
机构
[1] Univ Caxias do Sul, Ctr Ciencias Exatas & Tecnol, Caxias Do Sul, RS, Brazil
[2] Univ Caxias do Sul, Inst Biotecnol, Caxias Do Sul, RS, Brazil
[3] Univ Sao Paulo, Inst Fis, BR-01498 Sao Paulo, SP, Brazil
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2016年 / 58卷
关键词
Biosensors; Antibodies; Cystamine; Resonant frequency; Surface roughness; Escherichia coli; SALMONELLA-TYPHIMURIUM; RESONANCE SENSORS; ADHERENCE; TRANSFECTION; TEMPERATURE;
D O I
10.1016/j.msec.2015.08.029
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Escherichia coli are bacteria that must be controlled in the food industry and the hospital sector. Magnetoelastic biosensors offer the promise of rapid identification of these and other harmful antigens. In this work, strips of amorphous Metglas 2826MB3 were cut to size (5 mm x 1 mm) with a microdicing saw and were then coated with thin layers of Cr and Au, as verified by Rutherford backscattering spectroscopy (RBS). Several sensor surfaces were studied: 1) as-cast strip, wheel side; 2) as-cast strip, free surface; and 3) thinned and polished surface. A layer of cystamine was applied to the Au-covered magnetoelastic substrate, forming a self-assembled monolayer (SAM), followed by antibodies, using a modified Hermanson protocol. The cystamine layer growth was verified by Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM). The biosensors were exposed to solutions of bacteria and the resonant frequency of the sensors was measured with an impedance analyzer for times up to 100 min. Reductions in the resonant frequency, corresponding to bacteria capture, were measured after optimizing the signal amplitude. For times up to 40 min, high capture rates were observed and thereafter saturation occurred. Saturation values of the frequency shifts were compared with the number of bacteria observed on the sensor using fluorescence microscopy. Parameters associated with capture kinetics were studied for different sensor surfaces. The rough surfaces were found to show a faster response, while the thinned and polished sensors showed the largest frequency shift. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:541 / 547
页数:7
相关论文
共 38 条
  • [1] The influence of abutment surface roughness on plaque accumulation and peri-implant mucositis
    Bollen, CML
    Papaioanno, W
    VanEldere, J
    Schepers, E
    Quirynen, M
    vanSteenberghe, D
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (03) : 201 - 211
  • [2] Cancino J.C., 2008, THESIS
  • [3] Surface-scanning coil detectors for magnetoelastic biosensors: A comparison of planar-spiral and solenoid coils
    Chai, Yating
    Horikawa, Shin
    Wikle, Howard C.
    Wang, Zhenyu
    Chin, Bryan A.
    [J]. APPLIED PHYSICS LETTERS, 2013, 103 (17)
  • [4] Design of a surface-scanning coil detector for direct bacteria detection on food surfaces using a magnetoelastic biosensor
    Chai, Yating
    Wikle, Howard C.
    Wang, Zhenyu
    Horikawa, Shin
    Best, Steve
    Cheng, Zhongyang
    Dyer, Dave F.
    Chin, Bryan A.
    [J]. JOURNAL OF APPLIED PHYSICS, 2013, 114 (10)
  • [5] Dielectrophoresis-assisted 3D nanoelectroporation for non-viral cell transfection in adoptive immunotherapy
    Chang, Lingqian
    Gallego-Perez, Daniel
    Zhao, Xi
    Bertani, Paul
    Yang, Zhaogang
    Chiang, Chi-Ling
    Malkoc, Veysi
    Shi, Junfeng
    Sen, Chandan K.
    Odonnell, Lynn
    Yu, Jianhua
    Lu, Wu
    Lee, L. James
    [J]. LAB ON A CHIP, 2015, 15 (15) : 3147 - 3153
  • [6] Magnetic Tweezers-Based 3D Microchannel Electroporation for High-Throughput Gene Transfection in Living Cells
    Chang, Lingqian
    Howdyshell, Marci
    Liao, Wei-Ching
    Chiang, Chi-Ling
    Gallego-Perez, Daniel
    Yang, Zhaogang
    Lu, Wu
    Byrd, John C.
    Muthusamy, Natarajan
    Lee, L. James
    Sooryakumar, Ratnasingham
    [J]. SMALL, 2015, 11 (15) : 1818 - 1828
  • [7] `Small-volume solution current-time behavior study for application in reverse iontophoresis-based non-invasive blood glucose monitoring
    Chang LingQian
    Liu ChunXiu
    He YinZeng
    Xiao HongHui
    Cai XinXia
    [J]. SCIENCE CHINA-CHEMISTRY, 2011, 54 (01) : 223 - 230
  • [8] Polyelectrolyte/mesoporous silica hybrid materials for the high performance multiple-detection of pH value and temperature
    Chen, Feng
    Jiang, Xiaoping
    Kuang, Tairong
    Chang, Lingqian
    Fu, Dajiong
    Yang, Jintao
    Fan, Ping
    Zhong, Mingqiang
    [J]. POLYMER CHEMISTRY, 2015, 6 (18) : 3529 - 3536
  • [9] Chin B. A., 2014, U. S. Patent, Patent No. [20140120524 A1, 20140120524]
  • [10] Chu W.K., 1978, Backscattering Spectrometry, DOI DOI 10.1016/B978-0-12-173850-1.50008-9