Accuracy of four-dimensional phase-contrast velocity mapping for blood flow visualizations: a phantom study

被引:15
|
作者
Nilsson, Anders [1 ]
Bloch, Karin Markenroth [2 ]
Toger, Johannes [3 ,4 ]
Heiberg, Einar [3 ,4 ]
Stahlberg, Freddy [1 ,5 ]
机构
[1] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[2] Philips Healthcare, Best, Netherlands
[3] Lund Univ, Dept Clin Physiol, Skane Univ Hosp, Lund, Sweden
[4] Lund Univ, Ctr Math Sci, Lund, Sweden
[5] Lund Univ, Dept Diagnost Radiol, Lund, Sweden
关键词
Phase errors; background phase correction; blood flow visualization; phase-contrast imaging; velocity mapping; K-T BLAST; CARDIOVASCULAR MAGNETIC-RESONANCE; GREAT-VESSELS; MRI; 3D; SENSE; QUANTIFICATION; PATTERNS; HEART; FEASIBILITY;
D O I
10.1177/0284185113478005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Time-resolved three-dimensional, three-directional phase-contrast magnetic resonance velocity mapping (4D PC-MRI) is a powerful technique to depict dynamic blood flow patterns in the human body. However, the impact of phase background effects on flow visualizations has not been thoroughly studied previously, and it has not yet been experimentally demonstrated to what degree phase offsets affect flow visualizations and create errors such as inaccurate particle traces. Purpose: To quantify background phase offsets and their subsequent impact on particle trace visualizations in a 4D PC-MRI sequence. Additionally, we sought to investigate to what degree visualization errors are reduced by background phase correction. Material and Methods: A rotating phantom with a known velocity field was used to quantify background phase of 4D PC-MRI sequences accelerated with SENSE as well as different k-t BLAST speed-up factors. The deviation in end positions between particle traces in the measured velocity fields were compared before and after the application of two different phase correction methods. Results: Phantom measurements revealed background velocity offsets up to 7 cm/s (7% of velocity encoding sensitivity) in the central slice, increasing with distance from the center. Background offsets remained constant with increasing k-t BLAST speed-up factors. End deviations of up to 5.3 mm (1.8 voxels) in the direction perpendicular to the rotating disc were found between particle traces and the seeding plane of the traces. Phase correction by subtraction of the data from the stationary phantom reduced the average deviation by up to 56%, while correcting the data-set with a first-order polynomial fit to stationary regions decreased average deviation up to 78%. Conclusion: Pathline visualizations can be significantly affected by background phase errors, highlighting the importance of dedicated and robust phase correction methods. Our results show that pathline deviation can be substantial if adequate phase background errors are not minimized.
引用
收藏
页码:663 / 671
页数:9
相关论文
共 50 条
  • [1] Four-dimensional phase contrast MRI with accelerated dual velocity encoding
    Nett, Elizabeth J.
    Johnson, Kevin M.
    Frydrychowicz, Alex
    Del Rio, Alejandro Munoz
    Schrauben, Eric
    Francois, Christopher J.
    Wieben, Oliver
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (06) : 1462 - 1471
  • [2] Variable velocity encoding in a three-dimensional, three-directional phase contrast sequence: Evaluation in phantom and volunteers
    Nilsson, Anders
    Bloch, Karin Markenroth
    Carlsson, Marcus
    Heiberg, Einar
    Stahlberg, Freddy
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (06) : 1450 - 1459
  • [3] Multi-VENC Acquisition of Four-Dimensional Phase-Contrast MRI to Improve Precision of Velocity Field Measurement
    Ha, Hojin
    Kim, Guk Bae
    Kweon, Jihoon
    Kim, Young-Hak
    Kim, Namkug
    Yang, Dong Hyun
    Lee, Sang Joon
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (05) : 1909 - 1919
  • [4] Comprehensive four-dimensional phase-contrast flow assessment in hemi-Fontan circulation: systemic-to-pulmonary collateral flow quantification
    Valverde, Israel
    Rachel, Clough
    Kuehne, Titus
    Beerbaum, Philipp
    CARDIOLOGY IN THE YOUNG, 2011, 21 (01) : 116 - 119
  • [5] Analysis of the time-velocity curve in phase-contrast magnetic resonance imaging: a phantom study
    Park, Jieun
    Kim, Junghun
    Chang, Yongmin
    Youn, Sung Won
    Lee, Hui Joong
    Kang, Eun-Ju
    Lee, Ki-Nam
    Suchanek, Vojtech
    Hyun, Sinjae
    Lee, Jongmin
    COMPUTER ASSISTED SURGERY, 2019, 24 : 3 - 12
  • [6] Reconstruction of divergence-free velocity fields from cine 3D phase-contrast flow measurements
    Busch, Julia
    Giese, Daniel
    Wissmann, Lukas
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 200 - 210
  • [7] Applications of phase-contrast flow and velocity imaging in cardiovascular MRI
    Peter D. Gatehouse
    Jennifer Keegan
    Lindsey A. Crowe
    Sharmeen Masood
    Raad H. Mohiaddin
    Karl-Friedrich Kreitner
    David N. Firmin
    European Radiology, 2005, 15 : 2172 - 2184
  • [8] Applications of phase-contrast flow and velocity imaging in cardiovascular MRI
    Gatehouse, PD
    Keegan, J
    Crowe, LA
    Masood, S
    Mohiaddin, RH
    Kreitner, KF
    Firmin, DN
    EUROPEAN RADIOLOGY, 2005, 15 (10) : 2172 - 2184
  • [9] MR Phase-Contrast Velocity Mapping Methods for Measuring Venous Blood Velocity in the Deep Veins of the Calf
    Pierce, Iain T.
    Gatehouse, Peter D.
    Xu, X. Yun
    Firmin, David N.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (03) : 634 - 644
  • [10] Hemodynamic Measurement Using Four-Dimensional Phase-Contrast MRI: Quantification of Hemodynamic Parameters and Clinical Applications
    Ha, Hojin
    Kim, Guk Bae
    Kweon, Jihoon
    Lee, Sang Joon
    Kim, Young-Hak
    Lee, Deok Hee
    Yang, Dong Hyun
    Kim, Namkug
    KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (04) : 445 - 462