A randomized comparison of programmed intermittent epidural bolus with continuous epidural infusion for labor analgesia

被引:200
作者
Wong, CA [1 ]
Ratliff, JT [1 ]
Sullivan, JT [1 ]
Scavone, BM [1 ]
Toledo, P [1 ]
McCarthv, RT [1 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Anesthesiol, Chicago, IL 60611 USA
关键词
D O I
10.1213/01.ane.0000197778.57615.1a
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Bolus injection through an epidural catheter may result in better distribution of anesthetic solution in the epidural space compared with continuous infusion of the same anesthetic solution. In this randomized, double-blind study we compared total bupivacaine consumption, need for supplemental epidural analgesia, quality of analgesia, and patient satisfaction in women who received programmed intermittent epidural boluses (PIEB) compared with continuous epidural infusion (CEI) for maintenance of labor analgesia. The primary outcome variable was bupivacaine consumption per hour of analgesia. Combined spinal epidural analgesia was initiated in multiparas scheduled for induction of labor with cervical dilation between 2 and 5 cm. Subjects were randomized to PIEB (6-mL bolus every 30 min beginning 45 min after the intrathecal injection) or CEI (12-mL/h infusion beginning 15 min the after the intrathecal injection). The epidural analgesia solution was bupivacaine 0.625 mg/mL and fentanyl 2 mu g/mL. Breakthrough pain in both groups was treated initially with patient-controlled epidural analgesia (PCEA) followed by manual bolus rescue analgesia using bupivacaine 0.125%. The median total bupivacaine dose per hour of analgesia was less in the PIEB (n = 63) (10.5 mg/h; 95% confidence interval, 9.5-11.8 mg/h) compared with the CEI group (n = 63) (12.3 mg/h; 95% confidence interval, 10.5-14.0 mg/h) (P < 0.01), fewer manual rescue boluses were required (rate difference 22%, 95% confidence interval of difference 5% to 38%), and satisfaction scores were higher. Labor pain, PCEA requests, and delivered PCEA doses did not differ. PIEB combined with PCEA provided similar analgesia, but with a smaller bupivacaine dose and better patient satisfaction compared with CEI with PCEA for maintenance of epidural labor analgesia.
引用
收藏
页码:904 / 909
页数:6
相关论文
共 11 条
[1]   EXTRADURAL INFUSION OF 0.125-PERCENT BUPIVACAINE AT 10 ML H-1 TO WOMEN DURING LABOR [J].
BOGOD, DG ;
ROSEN, M ;
REES, GAD .
BRITISH JOURNAL OF ANAESTHESIA, 1987, 59 (03) :325-330
[2]   Comparison of intermittent epidural bolus, continuous epidural infusion and patient controlled-epidural analgesia during labor [J].
Boutros, A ;
Blary, S ;
Bronchard, R ;
Bonnet, F .
INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 1999, 8 (04) :236-241
[3]  
Chua SMH, 2004, CAN J ANAESTH, V51, P581, DOI 10.1007/BF03018402
[4]   An association between severe labor pain and cesarean delivery [J].
Hess, PE ;
Pratt, SD ;
Soni, AK ;
Sama, MC ;
Oriol, NE .
ANESTHESIA AND ANALGESIA, 2000, 90 (04) :881-886
[5]   Distribution of solution in the epidural space: Examination by cryomicrotome section [J].
Hogan, Q .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2002, 27 (02) :150-156
[6]   Epidural infusion: Continuous or bolus? [J].
Kaynar, AM ;
Shankar, KB .
ANESTHESIA AND ANALGESIA, 1999, 89 (02) :534-534
[7]   PLACENTAL-TRANSFER AND NEONATAL EFFECTS OF EPIDURAL SUFENTANIL AND FENTANYL ADMINISTERED WITH BUPIVACAINE DURING LABOR [J].
LOFTUS, JR ;
HILL, H ;
COHEN, SE .
ANESTHESIOLOGY, 1995, 83 (02) :300-308
[8]   Bupivacaine augments intrathecal fentanyl for labor analgesia [J].
Palmer, CM ;
Van Maren, G ;
Nogami, WM ;
Alves, D .
ANESTHESIOLOGY, 1999, 91 (01) :84-89
[9]   Determination of the minimal clinically significant difference on a patient visual analog satisfaction scale [J].
Singer, AJ ;
Thode, HC .
ACADEMIC EMERGENCY MEDICINE, 1998, 5 (10) :1007-1011
[10]   A COMPARATIVE-STUDY OF CONTINUOUS AND INTERMITTENT EPIDURAL ANALGESIA FOR LABOR AND DELIVERY [J].
SMEDSTAD, KG ;
MORISON, DH .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1988, 35 (03) :234-241