Optimizing working space in porcine laparoscopy: CT measurement of the effects of intra-abdominal pressure

被引:33
作者
Vlot, John [1 ]
Wijnen, Rene [1 ]
Stolker, Robert Jan [2 ]
Bax, Klaas [1 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Pediat Surg, NL-3000 CB Rotterdam, Netherlands
[2] Erasmus Univ, Med Ctr, Dept Anesthesiol, NL-3000 CB Rotterdam, Netherlands
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2013年 / 27卷 / 05期
关键词
Animal model; CO2; Computed tomography; Laparoscopy; Pneumoperitoneum; Working space; CONTROLLED VENTILATION; CARBON-DIOXIDE; RESPIRATORY MECHANICS; ABDOMINAL-WALL; CHOLECYSTECTOMY; SURGERY; PNEUMOPERITONEUM; INSUFFLATION; LENGTH; VIEW;
D O I
10.1007/s00464-012-2654-0
中图分类号
R61 [外科手术学];
学科分类号
摘要
Several factors may affect volume and dimensions of the working space in laparoscopic surgery. The precise impact of these factors has not been well studied. In a porcine model, we used computed tomographic (CT) scanning for measuring working space volume and distances. In a first series of experiments, we studied the relationship between intra-abdominal pressure (IAP) and working space. Eleven 20 kg pigs were studied under standardized anesthesia and volume-controlled ventilation. Cardiorespiratory parameters were monitored continuously, and blood gas samples were taken at different IAP levels. Respiratory rate was increased when ETCO2 exceeded 7 kPa. Breath-hold CT scans were made at IAP levels of 0, 5, 10, and 15 mmHg. Insufflator volumes were compared to CT-measured volumes. Maximum dimensions of pneumoperitoneum were measured on reconstructed CT images. Respiratory rate had to be increased in three animals. Mild hypercapnia and acidosis occurred at 15 mmHg IAP. Peak inspiratory pressure rose significantly at 10 and 15 mmHg. CT-measured volume increased relatively by 93 % from 5 to 10 mmHg IAP and by 19 % from 10 to 15 mmHg IAP. Comparing CT volumes to insufflator volumes gave a bias of 76 mL. The limits of agreement were -0.31 to +0.47, a range of 790 mL. The internal anteroposterior diameter increased by 18 % by increasing IAP from 5 to 10 mmHg and by 5 % by increasing IAP from 10 to 15 mmHg. At 15 mmHg, the total relative increase of the pubis-diaphragm distance was only 6 %. Abdominal width did not increase. CT allows for precise calculation of the actual CO2 pneumoperitoneum volume, whereas the volume of CO2 released by the insufflator does not. Increasing IAP up to 10 mmHg achieved most gain in volume and in internal anteroposterior diameter. At an IAP of 10 mmHg, higher peak inspiratory pressure was significantly elevated.
引用
收藏
页码:1668 / 1673
页数:6
相关论文
共 50 条
  • [41] Assessment of risk for intra-abdominal adhesions at laparoscopy for urological tumors
    Pautler, SE
    Phillips, JL
    Walther, MM
    JOURNAL OF UROLOGY, 2002, 168 (06) : 2391 - 2394
  • [42] Assessment of laparoscopic working space in guinea pigs (Cavia porcellus) undergoing carbon dioxide insufflation at different intra-abdominal pressures
    McCready, Julianne E.
    zur Linden, Alex R.
    Singh, Ameet
    Beaufrere, Hugues H.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2022, 83 (09)
  • [43] Laparoscopy for the impalpable testes: Experience with 80 intra-abdominal testes
    Hvistendahl, G. M.
    Poulsen, E. U.
    JOURNAL OF PEDIATRIC UROLOGY, 2009, 5 (05) : 389 - 392
  • [44] Low intra-abdominal pressure and deep neuromuscular blockade laparoscopic surgery and surgical space conditions A meta-analysis
    Wei, Yiyong
    Li, Jia
    Sun, Fude
    Zhang, Donghang
    Li, Ming
    Zuo, Yunxia
    MEDICINE, 2020, 99 (09)
  • [45] Differential Effects of Intra-Abdominal Hypertension and ARDS on Respiratory Mechanics in a Porcine Model
    Seybold, Benjamin
    Deutsch, Anna M.
    Deutsch, Barbara Luise
    Simeliunas, Emilis
    Weigand, Markus A.
    Fiedler-Kalenka, Mascha O.
    Kalenka, Armin
    MEDICINA-LITHUANIA, 2024, 60 (06):
  • [46] Relationship between Gastric pH Measurement and Intra-abdominal Pressure in Patients Undergoing Laparoscopic Surgery
    Cinar, Ayse Surhan
    Sayin, Pinar
    Celayir, Mustafa Fevzi
    MEDICAL BULLETIN OF SISLI ETFAL HOSPITAL, 2020, 54 (04): : 463 - 468
  • [47] Low vs. conventional intra-abdominal pressure in laparoscopic colorectal surgery: a prospective cohort study
    Hamid, Mohammed
    Zaman, Shafquat
    Mostafa, Omar Ezzat Saber
    Deutsch, Alex
    Bird, Jonty
    Kawesha, Anthony
    Reay, Michael
    Banga, Irmeet
    Williams, Anna
    Waterland, Peter
    Akingboye, Akinfemi
    LANGENBECKS ARCHIVES OF SURGERY, 2024, 410 (01)
  • [48] Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model
    Renner, Jochen
    Gruenewald, Matthias
    Quaden, Rene
    Hanss, Robert
    Meybohm, Patrick
    Steinfath, Markus
    Scholz, Jens
    Bein, Berthold
    CRITICAL CARE MEDICINE, 2009, 37 (02) : 650 - 658
  • [49] Cardiovascular and Respiratory Effects of Increased Intra-Abdominal Pressure with and without Dexmedetomidine in Anesthetized Dogs
    Kim, Dongseok
    Seo, Minjun
    Choi, Geonho
    Lee, Sang-Kwon
    Lee, Sungin
    Lee, Won-Jae
    Yun, Sung-Ho
    Kwon, Young-Sam
    Jang, Min
    VETERINARY SCIENCES, 2023, 10 (11)
  • [50] Assessment of the Smartpill, a Wireless Sensor, as a Measurement Tool for Intra-Abdominal Pressure (IAP)
    Soucasse, Andrea
    Jourdan, Arthur
    Edin, Lauriane
    Meunier, Elise
    Bege, Thierry
    Masson, Catherine
    SENSORS, 2024, 24 (01)