Optimizing working space in porcine laparoscopy: CT measurement of the effects of intra-abdominal pressure

被引:33
作者
Vlot, John [1 ]
Wijnen, Rene [1 ]
Stolker, Robert Jan [2 ]
Bax, Klaas [1 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Pediat Surg, NL-3000 CB Rotterdam, Netherlands
[2] Erasmus Univ, Med Ctr, Dept Anesthesiol, NL-3000 CB Rotterdam, Netherlands
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2013年 / 27卷 / 05期
关键词
Animal model; CO2; Computed tomography; Laparoscopy; Pneumoperitoneum; Working space; CONTROLLED VENTILATION; CARBON-DIOXIDE; RESPIRATORY MECHANICS; ABDOMINAL-WALL; CHOLECYSTECTOMY; SURGERY; PNEUMOPERITONEUM; INSUFFLATION; LENGTH; VIEW;
D O I
10.1007/s00464-012-2654-0
中图分类号
R61 [外科手术学];
学科分类号
摘要
Several factors may affect volume and dimensions of the working space in laparoscopic surgery. The precise impact of these factors has not been well studied. In a porcine model, we used computed tomographic (CT) scanning for measuring working space volume and distances. In a first series of experiments, we studied the relationship between intra-abdominal pressure (IAP) and working space. Eleven 20 kg pigs were studied under standardized anesthesia and volume-controlled ventilation. Cardiorespiratory parameters were monitored continuously, and blood gas samples were taken at different IAP levels. Respiratory rate was increased when ETCO2 exceeded 7 kPa. Breath-hold CT scans were made at IAP levels of 0, 5, 10, and 15 mmHg. Insufflator volumes were compared to CT-measured volumes. Maximum dimensions of pneumoperitoneum were measured on reconstructed CT images. Respiratory rate had to be increased in three animals. Mild hypercapnia and acidosis occurred at 15 mmHg IAP. Peak inspiratory pressure rose significantly at 10 and 15 mmHg. CT-measured volume increased relatively by 93 % from 5 to 10 mmHg IAP and by 19 % from 10 to 15 mmHg IAP. Comparing CT volumes to insufflator volumes gave a bias of 76 mL. The limits of agreement were -0.31 to +0.47, a range of 790 mL. The internal anteroposterior diameter increased by 18 % by increasing IAP from 5 to 10 mmHg and by 5 % by increasing IAP from 10 to 15 mmHg. At 15 mmHg, the total relative increase of the pubis-diaphragm distance was only 6 %. Abdominal width did not increase. CT allows for precise calculation of the actual CO2 pneumoperitoneum volume, whereas the volume of CO2 released by the insufflator does not. Increasing IAP up to 10 mmHg achieved most gain in volume and in internal anteroposterior diameter. At an IAP of 10 mmHg, higher peak inspiratory pressure was significantly elevated.
引用
收藏
页码:1668 / 1673
页数:6
相关论文
共 50 条
  • [31] CT scan-detected pneumoperitoneum: An unreliable predictor of intra-abdominal injury in blunt trauma
    Marek, Ashley P.
    Deisler, Ryan F.
    Sutherland, John B.
    Punjabi, Gopal
    Portillo, Anne
    Krook, Jon
    Richardson, Chad J.
    Nygaard, Rachel M.
    Ney, Arthur L.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (01): : 116 - 121
  • [32] Semicontinuous intra-abdominal pressure measurement using an intragastric Compliance catheter
    De Waele, Jan J.
    Berrevoet, F.
    Reyntjens, K.
    Pletinckx, P.
    De laet, I.
    Hoste, E.
    INTENSIVE CARE MEDICINE, 2007, 33 (07) : 1297 - 1300
  • [33] Effects of intra-abdominal pressure on respiratory system mechanics in mechanically ventilated rats
    Runck, Hanna
    Schumann, Stefan
    Tacke, Sabine
    Haberstroh, Joerg
    Guttmann, Josef
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2012, 180 (2-3) : 204 - 210
  • [34] Saline volume in transvesical intra-abdominal pressure measurement: enough is enough
    De Waele, J
    Pletinckx, P
    Blot, S
    Hoste, E
    INTENSIVE CARE MEDICINE, 2006, 32 (03) : 455 - 459
  • [35] Saline volume in transvesical intra-abdominal pressure measurement: enough is enough
    J. De Waele
    P. Pletinckx
    S. Blot
    E. Hoste
    Intensive Care Medicine, 2006, 32 : 455 - 459
  • [36] Effects of increased intra-abdominal pressure and volume expansion on renal function in the rat
    Lindström, P
    Wadström, J
    Ollerstam, A
    Johnsson, C
    Persson, AEG
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2003, 18 (11) : 2269 - 2277
  • [37] Semicontinuous intra-abdominal pressure measurement using an intragastric Compliance catheter
    Jan J. De Waele
    F. Berrevoet
    K. Reyntjens
    P. Pletinckx
    I. De laet
    E. Hoste
    Intensive Care Medicine, 2007, 33 : 1297 - 1300
  • [38] Effects of different intra-abdominal pressure values on different organs: what should be the ideal pressure?
    H. R. Aydin
    S. Kesici
    U. Kesici
    I. Saygin
    H. Ulusoy
    M. Imamoglu
    O. Deger
    European Surgery, 2014, 46 : 203 - 208
  • [39] Does applied ultrasound prior to laparoscopy predict the existence of intra-abdominal adhesions?
    Uslu Yuvaci, Hilal
    Cevrioglu, Arif Serhan
    Gunduz, Yasemin
    Akdemir, Nermin
    Karacan, Alper
    Erkorkmaz, Unal
    Keskin, Abdurrahim
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2020, 50 (02) : 304 - 311
  • [40] Evaluation of the Effects of Laparotomy and Laparoscopy on the Immune System in Intra-Abdominal Sepsis-A Review
    Karantonis, Fotios-Filippos
    Nikiteas, Nikolaos
    Perrea, Despina
    Vlachou, Antonia
    Giamarellos-Bourboulis, Evangelos J.
    Tsigris, Christos
    Kostakis, Alkiviadis
    JOURNAL OF INVESTIGATIVE SURGERY, 2008, 21 (06) : 330 - 339