摘要
Several factors may affect volume and dimensions of the working space in laparoscopic surgery. The precise impact of these factors has not been well studied. In a porcine model, we used computed tomographic (CT) scanning for measuring working space volume and distances. In a first series of experiments, we studied the relationship between intra-abdominal pressure (IAP) and working space. Eleven 20 kg pigs were studied under standardized anesthesia and volume-controlled ventilation. Cardiorespiratory parameters were monitored continuously, and blood gas samples were taken at different IAP levels. Respiratory rate was increased when ETCO2 exceeded 7 kPa. Breath-hold CT scans were made at IAP levels of 0, 5, 10, and 15 mmHg. Insufflator volumes were compared to CT-measured volumes. Maximum dimensions of pneumoperitoneum were measured on reconstructed CT images. Respiratory rate had to be increased in three animals. Mild hypercapnia and acidosis occurred at 15 mmHg IAP. Peak inspiratory pressure rose significantly at 10 and 15 mmHg. CT-measured volume increased relatively by 93 % from 5 to 10 mmHg IAP and by 19 % from 10 to 15 mmHg IAP. Comparing CT volumes to insufflator volumes gave a bias of 76 mL. The limits of agreement were -0.31 to +0.47, a range of 790 mL. The internal anteroposterior diameter increased by 18 % by increasing IAP from 5 to 10 mmHg and by 5 % by increasing IAP from 10 to 15 mmHg. At 15 mmHg, the total relative increase of the pubis-diaphragm distance was only 6 %. Abdominal width did not increase. CT allows for precise calculation of the actual CO2 pneumoperitoneum volume, whereas the volume of CO2 released by the insufflator does not. Increasing IAP up to 10 mmHg achieved most gain in volume and in internal anteroposterior diameter. At an IAP of 10 mmHg, higher peak inspiratory pressure was significantly elevated.
引用
收藏
页码:1668 / 1673
页数:6
相关论文
共 50 条
  • [21] Removal of intra-abdominal intrauterine device by laparoscopy
    Demir, SC
    Çetin, MT
    Ürünsak, IF
    Atay, Y
    Toksöz, L
    Kadayifçi, O
    EUROPEAN JOURNAL OF CONTRACEPTION AND REPRODUCTIVE HEALTH CARE, 2002, 7 (01) : 20 - 23
  • [22] The efffects of increased intra-abdominal pressure on bacterial translocation
    Polat, CK
    Aktepe, OC
    Akbulut, G
    Yilmaz, S
    Arikan, Y
    Dilek, ON
    Gokce, O
    YONSEI MEDICAL JOURNAL, 2003, 44 (02) : 259 - 264
  • [23] The role of laparoscopy in the treatment of intra-abdominal malignancies
    Lefor, AT
    CANCER JOURNAL, 2000, 6 : S159 - S168
  • [24] Noninvasive Assessment of Intra-Abdominal Pressure by Measurement of Abdominal Wall Tension
    van Ramshorst, Gabrielle H.
    Salih, Mahdi
    Hop, Wim C. J.
    van Waes, Oscar J. F.
    Kleinrensink, Gert-Jan
    Goossens, Richard H. M.
    Lange, Johan F.
    JOURNAL OF SURGICAL RESEARCH, 2011, 171 (01) : 240 - 244
  • [25] Impact of intra-abdominal insufflation pressure on gas leakage occurring during laparoscopy
    Jeffrey Dalli
    Tess Montminy
    Makenzie Ferguson
    Mohammad Faraz Khan
    Kevin Nolan
    Ronan A. Cahill
    Surgical Endoscopy, 2022, 36 : 7047 - 7055
  • [26] Impact of intra-abdominal insufflation pressure on gas leakage occurring during laparoscopy
    Dalli, Jeffrey
    Montminy, Tess
    Ferguson, Makenzie
    Khan, Mohammad Faraz
    Nolan, Kevin
    Cahill, Ronan A.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2022, 36 (09): : 7047 - 7055
  • [27] The uterine and tubal effects of laparoscopy in intra-abdominal infection: a rat model
    Ergin, T
    Tarim, E
    Zeyneloglu, HB
    Ergin, F
    Kuscu, E
    Haberal, A
    GYNAECOLOGICAL ENDOSCOPY, 2002, 11 (05) : 293 - 297
  • [28] Hemodynamic effects of increased intra-abdominal pressure in critically ill children
    Silveira, Leticia G. T.
    Brocca, Isabela C.
    Moraes, Erika S.
    Brandao, Marcelo B.
    Nogueira, Roberto J. N.
    de Souza, Tiago Henrique
    JORNAL DE PEDIATRIA, 2021, 97 (05) : 564 - 570
  • [29] Removal of intra-abdominal mislocated intrauterine devices by laparoscopy
    Balci, O.
    Capar, M.
    Mahmoud, A. S.
    Colakoglu, M. C.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2011, 31 (07) : 650 - 652
  • [30] Intra-Abdominal Pressure Development After Different Temporary Abdominal Closure Techniques in a Porcine Model
    Benninger, Emanuel
    Laschke, Matthias W.
    Cardell, Markus
    Keel, Marius
    Seifert, Burkhardt
    Trentz, Otmar
    Menger, Michael D.
    Meier, Christoph
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (04): : 1118 - 1124