Inter-laboratory comparison of different rapid methods for the detection of bacterial contamination in platelet concentrates

被引:16
|
作者
Vollmer, T. [1 ]
Hinse, D. [1 ]
Schottstedt, V. [2 ]
Bux, J. [2 ]
Tapernon, K. [3 ]
Sibrowski, W. [3 ]
Knabbe, C. [1 ]
Dreier, J. [1 ]
机构
[1] Ruhr Univ Bochum, Univ Klin, Inst Lab & Transfus Med, Herz & Diabet Zentrum N Rhein Westfalen, D-32545 Bad Oeynhausen, Germany
[2] DRK Blutspendedienst W, Zentrallabor Hagen, Germany
[3] Univ Klinikum Munster, Inst Transfus Med & Transplantat Immunol, Munster, Germany
关键词
BactiFlow; nucleic acid amplification techniques; Pan Genera detection; platelet bacteria screening; rapid methods; 6 YEARS EXPERIENCE; TECHNOLOGY; PCR;
D O I
10.1111/j.1423-0410.2011.01572.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Bacterial contamination of platelet concentrates still represents a major risk in transfusion medicine, and a variety of screening methods have been available to improve the safety of PCs. In the present study, the analytical quality of three different rapid screening methods (BactiFlow flow cytometry, Pan Genera Detection Assay, 23S rRNA RT-PCR) was evaluated in an inter-laboratory comparison in three different German blood services. Methods Samples were inoculated with different bacteria [Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli (two strains), Klebsiella pneumoniae (two strains), Enterobacter aerogenes (one strain), Serratia marcescens (one strain)] at different counts (4.5 X 1034.5 X 108 CFU/ml) alternating with negative samples in one transfusion facility. Samples were blinded with a random order for each screening method, shipped to partners and analysed immediately after receipt with different rapid screening methods. Results The inter-laboratory comparison revealed that the BactiFlow assay and 23S rRNA RT-PCR-screening detected all samples correctly (positive: 12/12, negative: 8/8). The Pan Genera Detection Assay test detected only four of the positive samples. Four of the non-detected positive samples were below the assays detection limit. Another four inoculated samples with comparatively high bacteria counts were detected false negative (E. coli (two strains): 9.87 X 105 and 2.10 X 107 CFU/ml, respectively, K. pneumoniae: 4.79 X 106 CFU/ml, S. aureus: 6.03 X 105 CFU/ml). All rapid screening methods revealed no false-positive results. Conclusions Both BactiFlow and 23S rRNA RT-PCR demonstrated a high sensitivity to detecting bacterial contamination in PCs. The Pan Genera Detection Assay had some shortcomings regarding sensitivity, especially for the detection of Gram-negative strains.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 47 条
  • [41] HAV detection from milk-based products containing soft fruits: Comparison between four different extraction methods
    Battistini, Roberta
    Rossini, Irene
    Listorti, Valeria
    Ercolini, Carlo
    Maurella, Cristiana
    Serracca, Laura
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2020, 328
  • [42] Detection of group B streptococcus colonisation in pregnant women: Comparison of two different culture methods and study of antimicrobial resistance patterns
    Carreras-Abad, Clara
    To, Ka-Ning
    Ramkhelawon, Laxmee
    Planche, Tim
    Monahan, Irene
    Djennad, Abdelmajid
    Chalker, Vicki
    Heath, Paul T.
    Le Doare, Kirsty
    JOURNAL OF INFECTION, 2021, 82 (05) : 186 - 188
  • [43] Comparison of Different Phenotypic Methods Including E-Test, Cefoxitin and Oxacillin Disk Diffusion for Detection of Methicillin Resistant Staphylococcus aureus
    GupTA, Geeta
    KuMAR, PRADEEp
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (02) : DC30 - DC32
  • [44] METHODS IN LABORATORY INVESTIGATION - RAPID AND SIMPLE DETECTION OF C-KI-RAS2 GENE CODON 12 MUTATIONS BY NONRADIOISOTOPIC SINGLE-STRAND CONFORMATION POLYMORPHISM ANALYSIS
    SUGANO, K
    KYOGOKU, A
    FUKAYAMA, N
    OHKURA, H
    SHIMOSATO, Y
    SEKIYA, T
    HAYASHI, K
    LABORATORY INVESTIGATION, 1993, 68 (03) : 361 - 366
  • [45] Comparison of four different methods (Stamp staining, capture-ELISA, PCR and cell culture) for the detection of the Q fever agent Coxiella burnetii
    Henning, K
    Sting, R
    BERLINER UND MUNCHENER TIERARZTLICHE WOCHENSCHRIFT, 2002, 115 (9-10): : 381 - 384
  • [46] Comparison of the BD MAX Enteric Bacterial Panel to Routine Culture Methods for Detection of Campylobacter, Enterohemorrhagic Escherichia coli (O157), Salmonella, and Shigella Isolates in Preserved Stool Specimens
    Anderson, Neil W.
    Buchan, Blake W.
    Ledeboer, Nathan A.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (04) : 1222 - 1224
  • [47] COMPARISON OF THE SENSITIVITY OF THE POLI-MERASE CHAIN REACTION FOR DETECTION OF CHLAMYDIA PNEUMONIAE INFECTIONS AFTER TWO DIFFERENT APPLIED METHODS FOR DNA EXTRACTION FROM SPUTA, TRACHEAL AND BRONCHIAL SECRETS
    Ouzounova, V.
    Mitov, I.
    JOURNAL OF IMAB, 2005, 11 (01): : 3 - 6