Inter-laboratory comparison of different rapid methods for the detection of bacterial contamination in platelet concentrates

被引:16
|
作者
Vollmer, T. [1 ]
Hinse, D. [1 ]
Schottstedt, V. [2 ]
Bux, J. [2 ]
Tapernon, K. [3 ]
Sibrowski, W. [3 ]
Knabbe, C. [1 ]
Dreier, J. [1 ]
机构
[1] Ruhr Univ Bochum, Univ Klin, Inst Lab & Transfus Med, Herz & Diabet Zentrum N Rhein Westfalen, D-32545 Bad Oeynhausen, Germany
[2] DRK Blutspendedienst W, Zentrallabor Hagen, Germany
[3] Univ Klinikum Munster, Inst Transfus Med & Transplantat Immunol, Munster, Germany
关键词
BactiFlow; nucleic acid amplification techniques; Pan Genera detection; platelet bacteria screening; rapid methods; 6 YEARS EXPERIENCE; TECHNOLOGY; PCR;
D O I
10.1111/j.1423-0410.2011.01572.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Bacterial contamination of platelet concentrates still represents a major risk in transfusion medicine, and a variety of screening methods have been available to improve the safety of PCs. In the present study, the analytical quality of three different rapid screening methods (BactiFlow flow cytometry, Pan Genera Detection Assay, 23S rRNA RT-PCR) was evaluated in an inter-laboratory comparison in three different German blood services. Methods Samples were inoculated with different bacteria [Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli (two strains), Klebsiella pneumoniae (two strains), Enterobacter aerogenes (one strain), Serratia marcescens (one strain)] at different counts (4.5 X 1034.5 X 108 CFU/ml) alternating with negative samples in one transfusion facility. Samples were blinded with a random order for each screening method, shipped to partners and analysed immediately after receipt with different rapid screening methods. Results The inter-laboratory comparison revealed that the BactiFlow assay and 23S rRNA RT-PCR-screening detected all samples correctly (positive: 12/12, negative: 8/8). The Pan Genera Detection Assay test detected only four of the positive samples. Four of the non-detected positive samples were below the assays detection limit. Another four inoculated samples with comparatively high bacteria counts were detected false negative (E. coli (two strains): 9.87 X 105 and 2.10 X 107 CFU/ml, respectively, K. pneumoniae: 4.79 X 106 CFU/ml, S. aureus: 6.03 X 105 CFU/ml). All rapid screening methods revealed no false-positive results. Conclusions Both BactiFlow and 23S rRNA RT-PCR demonstrated a high sensitivity to detecting bacterial contamination in PCs. The Pan Genera Detection Assay had some shortcomings regarding sensitivity, especially for the detection of Gram-negative strains.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 47 条
  • [31] Salmonella spp. contamination in commercial layer hen farms using different types of samples and detection methods
    Soria, M. C.
    Soria, M. A.
    Bueno, D. J.
    Godano, E. I.
    Gomez, S. C.
    ViaButron, I. A.
    Padin, V. M.
    Roge, A. D.
    POULTRY SCIENCE, 2017, 96 (08) : 2820 - 2830
  • [32] Comparison of two different PCR detection methods. Application to the diagnosis of pulmonary tuberculosis
    Rodriguez, JC
    Fuentes, E
    Royo, G
    APMIS, 1997, 105 (08) : 612 - 616
  • [33] Diagnosis of porcine proliferative enteropathies in pigs:: a comparison of different methods for the detection of Lawsonia intracellularis
    Dünser, M
    Untersperger, M
    Schweighardt, H
    Schuh, M
    Awad-Masalmeh, M
    TIERARZTLICHE PRAXIS AUSGABE GROSSTIERE NUTZTIERE, 2003, 31 (02): : 99 - 105
  • [34] A comparison of different DNA extraction methods and molecular techniques for the detection and identification of foodborne pathogens
    Papatheodorou, Spyridon Andreas
    Halvatsiotis, Panagiotis
    Houhoula, Dimitra
    AIMS MICROBIOLOGY, 2021, 7 (03): : 304 - 319
  • [35] Rapid detection of genetic mutations using the chemiluminescent hybridization protection assay (HPA): Overview and comparison with other methods
    Nelson, NC
    CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 1998, 35 (05) : 369 - 414
  • [36] Comparison of five different polymerase chain reaction methods for detection of human papillomavirus in cervical cell specimens
    Husnjak, K
    Grce, M
    Magdic, L
    Pavelic, K
    JOURNAL OF VIROLOGICAL METHODS, 2000, 88 (02) : 125 - 134
  • [37] Sensitivity of biochemical test in comparison with other methods for the detection of mycoplasma contamination in human and animal cell lines stored in the National Cell Bank of Iran
    Kazemiha, Vahid Molla
    Amanzadeh, Amir
    Memarnejadian, Arash
    Azari, Shahram
    Shokrgozar, Mohammad Ali
    Mahdian, Reza
    Bonakdar, Shahin
    CYTOTECHNOLOGY, 2014, 66 (05) : 861 - 873
  • [38] Comparison of different decontamination methods for reagents to detect low concentrations of bacterial 16S DNA by real-time-PCR
    Sven Klaschik
    Lutz E. Lehmann
    Ansgar Raadts
    Andreas Hoeft
    Frank Stuber
    Molecular Biotechnology, 2002, 22 : 231 - 242
  • [39] Comparison of different decontamination methods for reagents to detect low concentrations of bacterial 16S DNA by real-time-PCR
    Klaschik, S
    Lehmann, LE
    Raadts, A
    Hoeft, A
    Stuber, F
    MOLECULAR BIOTECHNOLOGY, 2002, 22 (03) : 231 - 242
  • [40] Rapid and simple DNA extraction method for the detection of enterotoxigenic Staphylococcus aureus directly from food samples: comparison of PCR and LAMP methods
    Sowmya, N.
    Thakur, M. S.
    Manonmani, H. K.
    JOURNAL OF APPLIED MICROBIOLOGY, 2012, 113 (01) : 106 - 113