Rarebit and frequency-doubling technology perimetry in children and young adults

被引:31
作者
Martin, L [1 ]
机构
[1] St Eriks Eye Hosp, Karolinska Inst, Sect Ophthalmol & Vis, Dept Clin Neurosci, S-11282 Stockholm, Sweden
来源
ACTA OPHTHALMOLOGICA SCANDINAVICA | 2005年 / 83卷 / 06期
关键词
children; frequency-doubling perimetry; rarebit perimetry;
D O I
10.1111/j.1600-0420.2005.00569.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe the outcome of visual field examinations performed with rarebit (RB) and frequency-doubling technology perimetry (FDT) in children and young adults. Methods: Twenty-one children (aged 6.5-12 years) and 30 teenagers and young adults (aged 14-20 years), participated in the study. Results: Reliable RB examinations were carried out in 76% of the younger group and 90% of the older group. Corresponding values for FDT were 57% and 90-95%, respectively. The RB results were very similar to those previously obtained in adult subjects, while some subjects showed borderline values in FDT, depending on the criteria used. The RB perimetry was preferred by 88% of the examined subjects. Conclusions: Rarebit perimetry seems useful for visual field examination in children aged 7 years and over, if age-corrected normative data are established; this test was also preferred by the tested subjects. No adaptation or special instructions were needed and the children found it rather amusing.
引用
收藏
页码:670 / 677
页数:8
相关论文
共 41 条
[1]  
Anderson AJ, 2002, INVEST OPHTH VIS SCI, V43, P398
[2]   Psychophysical evidence for a selective loss of M ganglion cells in glaucoma [J].
Anderson, RS ;
OBrien, C .
VISION RESEARCH, 1997, 37 (08) :1079-1083
[3]   Detection of optic neuropathy in glaucomatous eyes with normal standard visual fields using a test battery of short-wavelength automated perimetry and pattern electroretinography [J].
Bayer, AU ;
Maag, KP ;
Erb, C .
OPHTHALMOLOGY, 2002, 109 (07) :1350-1361
[4]  
Becker Kristine, 2003, Optometry, V74, P173
[5]   The reliability of frequency-doubling perimetry in young children [J].
Blumenthal, EZ ;
Haddad, A ;
Horani, A ;
Anteby, I .
OPHTHALMOLOGY, 2004, 111 (03) :435-439
[6]  
BROWN SM, 2005, GRAEFES ARCH CLIN EX
[7]   Probing glaucoma visual damage by rarebit perimetry [J].
Brusini, P ;
Salvetat, ML ;
Parisi, L ;
Zeppieri, M .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (02) :180-184
[8]   Comparison of frequency doubling perimetry with Humphrey visual field analysis in a glaucoma practice [J].
Burnstein, Y ;
Ellish, NJ ;
Magbalon, M ;
Higginbotham, EJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (03) :328-333
[9]   Frequency doubling technology perimetry for detection of glaucomatous visual field loss [J].
Cello, KE ;
Nelson-Quigg, JM ;
Johnson, CA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (03) :314-322
[10]   THE MOSAIC OF MIDGET GANGLION-CELLS IN THE HUMAN RETINA [J].
DACEY, DM .
JOURNAL OF NEUROSCIENCE, 1993, 13 (12) :5334-5355