Novel Automated Biomarker Discovery Work Flow for Urinary Peptidomics

被引:18
作者
Balog, Crina I. [1 ]
Hensbergen, Paul J. [1 ]
Derks, Rico [1 ]
Verweij, Jaco J. [1 ]
van Dam, Govert J. [1 ]
Vennervald, Birgitte J. [2 ]
Deelder, Andre M. [1 ]
Mayboroda, Oleg A. [1 ]
机构
[1] Leiden Univ Med Ctr, Dept Parasitol, Biomol Mass Spectrometry Unit, Ctr Infect Dis, NL-2300 RC Leiden, Netherlands
[2] Univ Copenhagen, Fac Life Sci, Dept Vet Pathobiol, DBL Ctr Hlth Res & Dev, Frederiksberg, Denmark
关键词
ENHANCED LASER-DESORPTION/IONIZATION; SCHISTOSOMA-HAEMATOBIUM INFECTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; ION-EXCHANGE CHROMATOGRAPHY; RENAL-ALLOGRAFT REJECTION; MASS-SPECTROMETRY; PROTEOMIC PATTERNS; OVARIAN-CANCER; HEMATURIA; PROTEINURIA;
D O I
10.1373/clinchem.2008.108795
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Urine is potentially a rich source of peptide biomarkers, but reproducible, high-throughput peptidomic analysis is often hampered by the inherent variability in factors such as pH and salt concentration. Our goal was to develop a generally applicable, rapid, and robust method for screening large numbers of urine samples, resulting in a broad spectrum of native peptides, as a tool to be used for biomarker discovery. METHODS: Peptide samples were trapped, desalted, pH-normalized, and fractionated on a miniaturized automatic reverse-phase strong cation exchange (RP-SCX) cartridge system. We analyzed eluted peptides using MALDI-TOF, Fourier transform ion cyclotron resonance, and liquid chromatography-iontrap mass spectrometry. We determined qualitative and quantitative reproducibility of the system and robustness of the method using BSA digests and urine samples, and we used a selected set of urine samples from Schistosoma haematobium-infected individuals to evaluate clinical applicability. RESULTS: The automated RP-SCX sample cleanup and fractionation system exhibits a high qualitative and quantitative reproducibility, with both BSA standards and urine samples. Because of the relatively high cartridge binding capacity (1-2 mL urine), eluted peptides can be measured with high sensitivity using multiple mass spectrometric techniques. As proof of principle, hemoglobin-derived peptides were identified in urine samples from S. haematobium-infected individuals, even when the microhematuria test was negative. CONCLUSIONS: We present a practical, step-by-step method for screening and identification of urinary peptides. Alongside the analytical method evaluation on standard samples, we demonstrate its feasibility with actual clinical material. (C) 2008 American Association for Clinical Chemistry
引用
收藏
页码:117 / 125
页数:9
相关论文
共 33 条
[1]  
Adam BL, 2002, CANCER RES, V62, P3609
[2]   A combined ion source for fast switching between electrospray and matrix-assisted laser desorption ionization in Fourier transform ion cyclotron resonance mass spectrometry [J].
Baykut, G ;
Fuchser, J ;
Witt, M ;
Weiss, G ;
Gosteli, C .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (17) :1631-1641
[3]   Characterization of renal allograft rejection by urinary proteomic analysis [J].
Clarke, W ;
Silverman, BC ;
Zhang, Z ;
Chan, DW ;
Klein, AS ;
Molmenti, EP .
ANNALS OF SURGERY, 2003, 237 (05) :660-664
[4]   Detection and analysis of urinary peptides by on-line liquid chromatography and mass spectrometry: application to patients with renal Fanconi syndrome [J].
Cutillas, PR ;
Norden, AGW ;
Cramer, R ;
Burlingame, AL ;
Unwin, RJ .
CLINICAL SCIENCE, 2003, 104 (05) :483-490
[5]   The use of proteomics in biomarker discovery in neurodegenerative diseases [J].
Davidsson, P ;
Sjögren, M .
DISEASE MARKERS, 2005, 21 (02) :81-92
[6]   Detection of colorectal cancer using MALDI-TOF serum protein profiling [J].
de Noo, ME ;
Mertens, BJA ;
Ozalp, A ;
Bladergroen, MR ;
van der Werff, MPJ ;
van de Velde, CJH ;
Deelder, AM ;
Tollenaar, RAEM .
EUROPEAN JOURNAL OF CANCER, 2006, 42 (08) :1068-1076
[7]   MALDI-TOF serum protein profiling for the detection of breast cancer [J].
de Noo, Mirre E. ;
Deelder, Andre ;
van der Werff, Martijn ;
Ozalp, Aliye ;
Mertens, Bart ;
Tollenaar, Rob .
ONKOLOGIE, 2006, 29 (11) :501-506
[8]   High-throughput proteomics and protein biomarker discovery in an experimental model of inflammatory hyperalgesia: Effects of nimesulide [J].
Gineste, C ;
Ho, L ;
Pompl, P ;
Bianchi, M ;
Pasinetti, GM .
DRUGS, 2003, 63 (Suppl 1) :23-29
[9]   Mapping of peptides and protein fragments in human urine using liquid chromatography mass spectrometry [J].
Heine, G ;
Raida, M ;
Forssmann, WG .
JOURNAL OF CHROMATOGRAPHY A, 1997, 776 (01) :117-124
[10]   Diagnostic potential for urinary proteomics [J].
Hortin, Glen L. ;
Sviridov, Denis .
PHARMACOGENOMICS, 2007, 8 (03) :237-255