Development of an analytical method for the determination of arsenic in gasoline samples by hydride generation-graphite furnace atomic absorption spectrometry

被引:26
|
作者
Becker, Emilene M. [2 ,3 ]
Dessuy, Morgana B. [1 ]
Boschetti, Wiliam [1 ]
Vale, Maria Goreti R. [1 ,4 ]
Ferreira, Sergio L. C. [4 ,5 ]
Welz, Bernhard [4 ,6 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
[2] Univ Fed Pampa, Bage, RS, Brazil
[3] Univ Fed Pelotas, Pelotas, RS, Brazil
[4] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol CNPq, INCT Energia & Ambiente, Salvador, BA, Brazil
[5] Univ Fed Bahia, Inst Quim, Salvador, BA, Brazil
[6] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
关键词
Gasoline; Sample preparation; Arsenic determination; In-situ trapping; HG-GF AAS; VAPOR GENERATION; NAPHTHA; PRECONCENTRATION; OPTIMIZATION; DIGESTION; ELEMENTS; MERCURY; METALS; DIESEL; OIL;
D O I
10.1016/j.sab.2012.04.006
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The purpose of the present work was to optimize the conditions for the determination of arsenic in gasoline with hydride generation-graphite furnace atomic absorption spectrometry after acid digestion using a full two-level factorial design with center point. The arsine was generated in a batch system and collected in a graphite tube coated with 150 mu g Ir as a permanent modifier. The sample volume, the pre-reduction conditions, the temperature program and modifier mass were kept fixed for all experiments. The estimated main effects were: reducing agent concentration (negative effect), acid concentration (negative effect) and trapping temperature (positive effect). It was observed that there were interactions between the variables. Moreover, the curvature was significant, indicating that the best conditions were at the center point. The optimized parameters for arsine generation were 2.7 mol L-1 hydrochloric acid and 1.6% (w/v) sodium tetrahydroborate. The optimized conditions to collect arsine in the graphite furnace were a trapping temperature of 250 degrees C and a collection time of 30s. The limit of detection was 6.4 ng L-1 and the characteristic mass was 24 pg. Two different systems for acid digestion were used: a digester block with cold finger and a microwave oven. The concentration of arsenic found with the proposed method was compared with that obtained using a detergendess microemulsion and direct graphite furnace determination. The results showed that the factorial design is a simple tool that allowed establishing the appropriate conditions for sample preparation and also helped in evaluating the interaction between the factors investigated. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:102 / 106
页数:5
相关论文
共 50 条
  • [21] Separation of arsenic species in aqueous solutions and optimization of determination by graphite furnace atomic absorption spectrometry
    Latva, S
    Hurtta, M
    Peräniemi, S
    Ahlgrén, M
    ANALYTICA CHIMICA ACTA, 2000, 418 (01) : 11 - 17
  • [22] HYDRIDE GENERATION ATOMIC-ABSORPTION DETERMINATION OF TELLURIUM SPECIES IN ENVIRONMENTAL-SAMPLES WITH INSITU CONCENTRATION IN A GRAPHITE-FURNACE
    YOON, BM
    SHIM, SC
    PYUN, HC
    LEE, DS
    ANALYTICAL SCIENCES, 1990, 6 (04) : 561 - 566
  • [23] Underestimation of total arsenic concentration in groundwater samples determined by hydride generation quartz furnace atomic absorption spectrometry due to sample characteristics
    A. Ramesh Kumar
    P. Riyazuddin
    Accreditation and Quality Assurance, 2007, 12 : 455 - 458
  • [24] Underestimation of total arsenic concentration in groundwater samples determined by hydride generation quartz furnace atomic absorption spectrometry due to sample characteristics
    Kumar, A. Ramesh
    Riyazuddin, P.
    ACCREDITATION AND QUALITY ASSURANCE, 2007, 12 (09) : 455 - 458
  • [25] Optimization of Analytical Strategy for Determination of Total Antimony in Fish Muscle Tissue using Hydride Generation Atomic Absorption Spectrometry
    Silva Junior, Mario M.
    Leao, Danilo J.
    Silva, Laiana O. B.
    Pimentel, Catilea Franca
    Garcia, Karina Santos
    Ferreira, Sergio L. C.
    CURRENT ANALYTICAL CHEMISTRY, 2017, 13 (04) : 285 - 290
  • [26] Speciation analysis of inorganic form of arsenic in ground water samples by hydride generation atomic absorption spectrometry with insitu trapping in graphite tube
    Niedzielski, P
    Siepak, M
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2005, 3 (01): : 82 - 94
  • [27] Bismuth determination in environmental samples by hydride generation-electrothermal atomic absorption spectrometry
    Moscoso-Pérez, C
    Moreda-Piñeiro, J
    López-Mahía, P
    Muniategui-Lorenzo, S
    Fernández-Fernández, E
    Prada-Rodríguez, D
    TALANTA, 2003, 61 (05) : 633 - 642
  • [28] Determination of Cadmiun In Environmental Samples by Graphite Furnace Atomic Absorption Spectrometry with Cloud Point Extraction
    Song Xue-Jie
    Liu Xin-Li
    Duan Tai-Cheng
    Chen Hang-Ting
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (06) : 893 - 896
  • [29] Cloud-Point Extraction/Graphite Furnace Atomic Absorption Spectrometry for the Determination of Trace Rhodium in Water Samples
    Yang, Xiaohui
    Han, Quan
    Wang, Huan
    Huo, Yanyan
    Yang, Longhu
    He, Yaping
    Wu, Jiangyan
    AMERICAN LABORATORY, 2019, 51 (03) : 22 - 25
  • [30] Minimization of volatile nitrogen oxides interference in the determination of arsenic by hydride generation atomic absorption spectrometry
    Flores, ÉMD
    da Silva, LLC
    Barin, JS
    Saidelles, APF
    Zanella, R
    Dressler, VL
    Paniz, JNG
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (10) : 1883 - 1891