Quantifying image distortion of orthopedic materials in magnetic resonance imaging

被引:51
作者
Koff, Matthew F. [1 ]
Shah, Parina [1 ]
Koch, Kevin M. [2 ]
Potter, Hollis G. [1 ]
机构
[1] Hosp Special Surg, Dept Radiol & Imaging, New York, NY 10021 USA
[2] Gen Elect Healthcare, Appl Sci Lab, Waukesha, WI USA
关键词
susceptibility; artifact; metal; METAL ARTIFACT REDUCTION; SPIN-ECHO; MRI; ARTHROPLASTY; OSTEOLYSIS; CT; IMPLANTS; HIP;
D O I
10.1002/jmri.23991
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the magnitude of image distortion between two-dimensional (2D) fast-spin-echo (FSE) images and 3D-MAVRIC by using a phantom with samples of common materials used in total joint arthroplasty. Materials and Methods: A phantom was constructed to hold samples of 316 stainless steel, cobalt chrome, titanium, and ultra-high molecular weight polyethylene (UHMWPE), and to permit tracking of points between 2D-FSE and 3D-MAVRIC sequences. Imaging was performed with a 1.5 Tesla scanner. The displacement of points between the two acquisitions in regions of varying distance from the material sample was calculated. Measured displacements were compared with theoretical displacements calculated from MAVRIC frequency field maps, and to the known phantom dimensions. Results: Bulk in-plane artifacts increased from the control scan (0.20 +/- 0.07 mm), to UHMWPE (0.23 +/- 0.04 mm), titanium (0.40 +/- 0.34 mm), cobalt chrome (1.35 +/- 0.57 mm), and to stainless steel (2.56 +/- 0.62 mm). A similar pattern was found for bulk through-plane measurements: control scan (0.36 +/- 0.08 mm), UHMWPE (0.38 +/- 0.05 mm), titanium (1.11 +/- 0.51 mm), and cobalt chrome (2.08 +/- 1.83 mm). Large distortions were observed near the metal samples, and reduced with distance from the samples. The differences between the measured displacement and theoretical displacement was typically less than one pixel or one slice dimension for in-plane and through-plane measurements, respectively. The difference between the 3D-MAVRIC and known dimensions of the phantom was less than two pixels, whereas the results for the 2D-FSE were less consistent. Conclusion: Distortion was reduced in 3D-MAVRIC scans. Measured distortions corresponded well to theoretical calculations from frequency field map data. J. Magn. Reson. Imaging 2013;38:610-618. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:610 / 618
页数:9
相关论文
共 38 条
[1]   MR IMAGING OF LARGE NONFERROMAGNETIC METALLIC IMPLANTS AT 1.5-T [J].
AUGUSTINY, N ;
VONSCHULTHESS, GK ;
MEIER, D ;
BOSIGER, P .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (04) :678-683
[2]   Single-point ramped imaging with T-1 enhancement (SPRITE) [J].
Balcom, BJ ;
MacGregor, RP ;
Beyea, SD ;
Green, DP ;
Armstrong, RL ;
Bremner, TW .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1996, 123 (01) :131-134
[3]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[4]   Magnetic field mapping around metal implants using an asymmetric spin-echo MRI sequence [J].
Bartusek, K. ;
Dokoupil, Z. ;
Gescheidtova, E. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (12) :3293-3300
[5]   Relaxation time mapping of short T2* nuclei with single-point imaging (SPI) methods [J].
Beyea, SD ;
Balcom, BJ ;
Prado, PJ ;
Cross, AR ;
Kennedy, CB ;
Armstrong, RL ;
Bremner, TW .
JOURNAL OF MAGNETIC RESONANCE, 1998, 135 (01) :156-164
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   Reduction of blurring in view angle tilting MRI [J].
Butts, K ;
Pauly, JM ;
Gold, GE .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) :418-424
[8]  
Carl M, 2012, MAGN RESON MED
[9]   MRI of spinal hardware: comparison of conventional T1-weighted sequence with a new metal artifact reduction sequence [J].
Chang, SD ;
Lee, MJ ;
Munk, PL ;
Janzen, DL ;
MacKay, A ;
Xiang, QS .
SKELETAL RADIOLOGY, 2001, 30 (04) :213-218
[10]   New MR Imaging Methods for Metallic Implants in the Knee: Artifact Correction and Clinical Impact [J].
Chen, Christina A. ;
Chen, Weitian ;
Goodman, Stuart B. ;
Hargreaves, Brian A. ;
Koch, Kevin M. ;
Lu, Wenmaio ;
Brau, Anja C. ;
Draper, Christine E. ;
Delp, Scott L. ;
Gold, Garry E. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (05) :1121-1127