Cryo-EM model validation using independent map reconstructions

被引:60
|
作者
DiMaio, Frank [1 ]
Zhang, Junjie [2 ]
Chiu, Wah [3 ]
Baker, David [1 ]
机构
[1] Univ Washington, Dept Biochem, Seattle, WA 98195 USA
[2] Stanford Univ, Sch Med, Dept Biol Struct, Stanford, CA 94305 USA
[3] Baylor Coll Med, Natl Ctr Macromol Imaging, Verna & Marrs McLean Dept Biochem & Mol Biol, Houston, TX 77030 USA
关键词
cryo-electron microscopy; protein structure; model validation; model refinement; ELECTRON CRYOMICROSCOPY; REFINEMENT;
D O I
10.1002/pro.2267
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
An increasing number of cryo-electron microscopy (cryo-EM) density maps are being generated with suitable resolution to trace the protein backbone and guide sidechain placement. Generating and evaluating atomic models based on such maps would be greatly facilitated by independent validation metrics for assessing the fit of the models to the data. We describe such a metric based on the fit of atomic models with independent test maps from single particle reconstructions not used in model refinement. The metric provides a means to determine the proper balance between the fit to the density and model energy and stereochemistry during refinement, and is likely to be useful in determining values of model building and refinement metaparameters quite generally.
引用
收藏
页码:865 / 868
页数:4
相关论文
共 50 条
  • [1] Outcomes of the Cryo-EM Map and Model Challenges
    Lawson, Catherine L.
    Kryshtafovych, Andriy
    Pintilie, Grigore
    Berman, Helen M.
    Chiu, Wah
    BIOPHYSICAL JOURNAL, 2019, 116 (03) : 160A - 160A
  • [2] Validation tests for cryo-EM maps using an independent particle set
    Ortiz, Sebastian
    Stanisic, Luka
    Rodriguez, Boris A.
    Rampp, Markus
    Hummer, Gerhard
    Cossio, Pilar
    JOURNAL OF STRUCTURAL BIOLOGY-X, 2020, 4
  • [3] Tools for the cryo-EM gold rush: going from the cryo-EM map to the atomistic model
    Kim, Doo Nam
    Sanbonmatsu, Karissa Y.
    BIOSCIENCE REPORTS, 2017, 37
  • [4] Cryo-EM Map-Based Model Validation Using the False Discovery Rate Approach
    Olek, Mateusz
    Joseph, Agnel Praveen
    FRONTIERS IN MOLECULAR BIOSCIENCES, 2021, 8
  • [5] Single particle cryo-EM map and model validation: It's not crystal clear
    Lander, Gabriel C.
    CURRENT OPINION IN STRUCTURAL BIOLOGY, 2024, 89
  • [6] Using Molecular Simulation to Model High-Resolution Cryo-EM Reconstructions
    Kirmizialtin, Serdal
    Loerke, Justus
    Behrmann, Elmar
    Spahn, Christian M. T.
    Sanbonmatsu, Karissa Y.
    STRUCTURES OF LARGE RNA MOLECULES AND THEIR COMPLEXES, 2015, 558 : 497 - 514
  • [7] Interpreting the cryo-EM map
    Rosenthal, Peter B.
    IUCRJ, 2019, 6 : 3 - 4
  • [8] How reliable are atomic models based on cryo-EM reconstructions? Improvements in model fitting and validation
    Rey, Felix
    Botte, Mathieu
    Neumann, Piotr
    Fischer, Niels
    Stark, Holger
    Ficner, Ralf
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2016, 72 : S45 - S45
  • [9] Improving the visualization of cryo-EM density reconstructions
    Spiegel, M.
    Duraisamy, A. K.
    Schroeder, G. F.
    JOURNAL OF STRUCTURAL BIOLOGY, 2015, 191 (02) : 207 - 213
  • [10] Structural interpretation of cryo-EM image reconstructions
    Beckers, Maximilian
    Mann, Daniel
    Sachse, Carsten
    PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 2021, 160 : 26 - 36