Thermal optimization of a natural draft wet cooling tower

被引:29
作者
Williamson, N. [1 ]
Behnia, M.
Armfield, S. W. [1 ]
机构
[1] Univ Sydney, Sch Mech & Aerosp Engn, Sydney, NSW 2006, Australia
关键词
Poppe method; Merkel method; cooling tower; optimization;
D O I
10.1002/er.1456
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study attempts to quantify the potential improvement in a natural draft wet cooling tower (NDWCT) performance that can be attained by optimizing the fill and water distribution profiles across the tower and to provide designers with the modelling tools for such an investigation. A simple two-dimensional (2D) model is described, which allows rapid evaluation of NDWCT performance for use with an optimization procedure. This model has been coupled with an evolutionary optimization algorithm to determine the optimal fill shape and water distribution profile to maximize the cooling range of a typical NDWCT. The results are compared against a 2D axisymmetric numerical model. The extended I D model is found to significantly reduce computational time compared with the numerical model, allowing a wide range of parameters to be tested rapidly with reasonable accuracy. The results show that the optimal layout differs significantly from a uniform profile, with both the water flow rate and the fill depth decreasing towards the centre of the tower where the air is warmer with reduced cooling potential. The overall improvement in the tower cooling range is very low under the design conditions tested, due largely to the highly coupled nature of the airflow and heat transfer in the tower. It is concluded that any design modifications of the type considered would need to be carefully optimized to have any possibility of improving performance. Copyright (c) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:1349 / 1361
页数:13
相关论文
共 25 条
[21]   Comparison of a 2D axisymmetric CFD model of a natural draft wet cooling tower and a 1D model [J].
Williamson, N. ;
Behnia, M. ;
Armfield, S. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2008, 51 (9-10) :2227-2236
[22]   Numerical simulation of flow in a natural draft wet cooling tower The effect of radial thermofluid fields [J].
Williamson, N. ;
Armfield, S. ;
Behnia, M. .
APPLIED THERMAL ENGINEERING, 2008, 28 (2-3) :178-189
[23]  
Williamson N. J., 2008, THESIS U SYDNEY SYDN
[24]   Structural application of a shape optimization method based on a genetic algorithm [J].
Woon, SY ;
Querin, OM ;
Steven, GP .
STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2001, 22 (01) :57-64
[25]   A genetic algorithm for the shape optimization of parts subjected to thermal loading [J].
Younes, M ;
Potiron, A .
NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2001, 39 (05) :449-470