Experimental investigation on heat transfer deterioration of supercritical pressure water in vertically-upward internally-ribbed tubes

被引:26
|
作者
Zhang, Weiqiang [1 ]
Li, Huixiong [1 ]
Zhang, Qing [2 ]
Lei, Xianliang [1 ]
Zhang, Qian [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Shaanxi, Peoples R China
[2] China Huaneng Clean Energy Res Inst, Beijing 102209, Peoples R China
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
Supercritical pressure water; Internally-ribbed tube; Heat transfer deterioration; Buoyancy effect; Heat transfer coefficient; LOW-MASS FLUX; RIFLED TUBE; EMPIRICAL CORRELATIONS; HYDRAULIC RESISTANCE; FLOW; CHANNELS; BEHAVIOR; FLUIDS;
D O I
10.1016/j.ijheatmasstransfer.2017.12.097
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presented an experimental investigation into heat transfer deterioration (HTD) characteristics of supercritical pressure water (SCW) flowing vertically upward in eight internally-ribbed tubes (IRT). The experiment was carried out at the following operating conditions: pressures from 25 to 28 MPa, mass velocities from 400 to 800 kg m(-2) S-1, and inner wall heat fluxes from 400 to 1000 kW m(-2). The results show that HTD of SCW might occur in the large specific heat region (LSHR) with increasing of q/G, but the increase of pressure could suppress the severity of HTD in the test IRTs. Based on the experimental data, the differences of heat transfer behavior among a series of IRTs, and the differences between IRTs and smooth tubes were compared separately. To explain the mechanism of unusual heat transfer, the buoyancy effect and flow acceleration were further analyzed based on the previous criteria. It was found that the dimensionless number (Gr(b)) over bar /Re-b(2.7) in all IRTs was much larger than that in smooth tubes under HTD occurrence, while dimensionless number 1Cvt for flow acceleration in all test IRTs was much less than the threshold value when HTD came out in smooth tubes for SCW. Therefore, a new improved heat transfer criterion by adding the rib geometry parameters of IRTs was proposed for predicating HTD of SCW according to the experimental data. Also, after evaluating the existing heat transfer coefficient (HTC) correlations of SCW for IRTs, it was found that all previous correlations cannot accurately predict HTC and wall temperature profiles of IRTs at HTD conditions. Thus, an improved HTC predicating correlation for HTD was proposed regarding to the effect of rib geometry and buoyancy that can be to precisely predict wall temperatures and HTCs in various IRTs. Meanwhile, the new correlation was also verified to be more effective than the previous correlations. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:930 / 943
页数:14
相关论文
共 50 条
  • [31] Experimental study on heat transfer behavior and prediction of heat transfer deterioration of supercritical nitrogen in vertical tubes
    Xiao, Runfeng
    Chen, Liang
    Hou, Yu
    Du, Chang
    Cai, Yuqing
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 155
  • [32] Experimental Research on the Flow and Heat Transfer Characteristics of Subcritical and Supercritical Water in the Vertical Upward Smooth and Rifled Tubes
    Du, Xiaocheng
    Li, Weiteng
    Zhang, Xirong
    Chen, Jingrong
    Chen, Tingyu
    Yang, Dong
    ENERGIES, 2022, 15 (21)
  • [33] Study on identification method of heat transfer deterioration of supercritical fluids in vertically heated tubes
    Zhang, Qian
    Li, Huixiong
    Lei, Xianliang
    Zhang, Jun
    Kong, Xiangfei
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 127 : 674 - 686
  • [34] Experimental and numerical investigation on the mechanisms of novel heat transfer deterioration of supercritical CO2 in vertical tubes
    Yang, Zenan
    Wang, Hao
    Guan, Ben
    Yang, Haiwei
    Li, Zehuan
    Wang, Ge
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 153
  • [35] Experimental investigation on heat transfer characteristics of supercritical pressure water in a horizontal tube
    Yu, Shuiqing
    Li, Huixiong
    Lei, Xianliang
    Feng, Yongchang
    Zhang, Yifan
    He, Hong
    Wang, Tai
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 50 : 213 - 221
  • [36] A dimensionless correlation to predict the onset of heat transfer deterioration of supercritical fluids in upward circular tubes
    Xiao, Runfeng
    Tian, Gui
    Chen, Liang
    Hou, Yu
    Chen, Shuangtao
    NUCLEAR ENGINEERING AND DESIGN, 2022, 392
  • [37] Numerical study of effects of vortex generators on heat transfer deterioration of supercritical water upward flow
    Eze, Chika
    Wong, Kin Wing
    Gschnaidtne, Tobias
    Cai, J.
    Zhao, Jiyun
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 137 : 489 - 505
  • [38] Numerical study on heat transfer deterioration of supercritical aviation kerosene in vertical upward circular tubes
    School of Energy and Power Engineering, Dalian University of Technology, Dalian
    116024, China
    Tuijin Jishu, 1 (97-103): : 97 - 103
  • [39] Development of a new empirical correlation for the prediction of the onset of the deterioration of heat transfer to supercritical water in vertical tubes
    Schatte, Gerrit A.
    Kohlhepp, Andreas
    Wieland, Christoph
    Spliethoff, Hartmut
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 113 : 1333 - 1341
  • [40] Concept of a measurement and test station to determine linear pressure drop and the heat transfer coefficient of internally ribbed tubes
    Majewski, Karol
    JOURNAL OF POWER TECHNOLOGIES, 2013, 93 (05): : 340 - 346