Skin-prick blood samples are reliable for estimating Hb mass with the CO-dilution technique

被引:9
作者
Ashenden, MJ
Gore, CJ
Burge, CM
Clough, ML
Bourdon, PE
Dobson, GP
Hahn, AG
机构
[1] Australian Inst Sport, Dept Physiol, Belconnen, ACT 2616, Australia
[2] James Cook Univ N Queensland, Dept Physiol & Pharmacol, Townsville, Qld 4811, Australia
[3] S Australian Sports Inst, Adelaide, SA, Australia
[4] Univ Ballarat, Sch Human Movement & Sports Sci, Ballarat, Vic, Australia
[5] Australian Inst Sport, Dept Physiol & Appl Nutr, Canberra, ACT, Australia
关键词
carbon monoxide; hemoglobin; OSM3; capillary blood;
D O I
10.1007/s004210050549
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Investigation of the impact of environmental stimuli such as altitude exposure on hemoglobin mass currently rely on invasive techniques that require venous blood sampling. This study assessed the feasibility of lancet skin pricks as an alternative to venepuncture to estimate hemoglobin mass with the carbon monoxide (CO) dilution technique, with the intent of making the technique accessible to technicians without phlebotomy training. Sixteen healthy volunteers rebreathed CO via a small-volume rebreathing apparatus. Blood was sampled simultaneously with a glass syringe (VEN) from a superficial forearm vein and with a capillary tube from either a lanced fingertip or earlobe (CAP). As a control, VEN blood was then aliquoted into capillary tubes (CONTROL-CAP). Samples were assayed for carboxyhemoglobin (HbCO) using a diode-array spectrophotometer. Mean %HbCO was higher in CAP than VEN (bias 0.3 +/- 0.2%HbCO, p < 0.01), but VEN and CONTROL-CAP were not different (p = 0.55). Compared to VEN, Hb mass derived from CAP samples was overestimated by 1.7% (15 +/- 22 g Hb p = 0.01). CAP samples to estimate Hb mass demons;rated a technical error of measurement of 2.7%, which is comparable to the 1.9% reported previously with VEN samples. We conclude that using CAP samples gives a reliable measure of %HbCO, and will make the estimation of Hb mass with the CO-technique accessible to technicians without phlebotomy training.
引用
收藏
页码:535 / 537
页数:3
相关论文
共 10 条
[1]  
Armitage P., 1971, STAT METHODS MED RES
[2]   HIGH-ALTITUDE TRAINING - ASPECTS OF HEMATOLOGICAL ADAPTATION [J].
BERGLUND, B .
SPORTS MEDICINE, 1992, 14 (05) :289-303
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   DETERMINATION OF HEMOGLOBIN MASS AND BLOOD-VOLUME WITH CO - EVALUATION AND APPLICATION OF A METHOD [J].
BURGE, CM ;
SKINNER, SL .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 79 (02) :623-631
[5]   PRECISION OF A NEW BEDSIDE METHOD FOR ESTIMATION OF THE CIRCULATING BLOOD-VOLUME [J].
CHRISTENSEN, P ;
ERIKSEN, B ;
HENNEBERG, SW .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1993, 37 (06) :622-627
[6]  
Denegar CR, 1993, J SPORT REHABIL, V2, P35, DOI DOI 10.1123/JSR.2.1.35
[7]   PH EFFECT ON THE COHB ABSORPTION-SPECTRUM - IMPORTANCE FOR CALIBRATION OF THE OSM3 AND MEASUREMENT OF CIRCULATING HEMOGLOBIN AND BLOOD-VOLUME [J].
FOGHANDERSEN, N ;
THOMSEN, JK ;
FOLDAGER, N ;
SIGGAARDANDERSEN, O .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1990, 50 :247-252
[8]  
Gore CJ, 1997, INT J SPORTS MED, V18, P477
[9]   EFFECTS OF THERMAL-STRESS AND EXERCISE ON BLOOD-VOLUME IN HUMANS [J].
HARRISON, MH .
PHYSIOLOGICAL REVIEWS, 1985, 65 (01) :149-209
[10]   New aspects of altitude training [J].
Rusko, HR .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1996, 24 :S48-S52