You Can't Touch This: Touch-free Navigation Through Radiological Images

被引:59
作者
Ebert, Lars C. [1 ,2 ]
Hatch, Gary [2 ]
Ampanozi, Garyfalia [2 ]
Thali, Michael J. [2 ]
Ross, Steffen [3 ]
机构
[1] Univ Zurich, Inst Forens Med, CH-8057 Zurich, Switzerland
[2] Univ Bern, Bern, Switzerland
[3] Linkoping Univ, Linkoping, Sweden
关键词
image-guided surgery; biomedical engineering; surgical education;
D O I
10.1177/1553350611425508
中图分类号
R61 [外科手术学];
学科分类号
摘要
Keyboards, mice, and touch screens are a potential source of infection or contamination in operating rooms, intensive care units, and autopsy suites. The authors present a low-cost prototype of a system, which allows for touch-free control of a medical image viewer. This touch-free navigation system consists of a computer system (IMac, OS X 10.6 Apple, USA) with a medical image viewer (OsiriX, OsiriX foundation, Switzerland) and a depth camera (Kinect, Microsoft, USA). They implemented software that translates the data delivered by the camera and a voice recognition software into keyboard and mouse commands, which are then passed to OsiriX. In this feasibility study, the authors introduced 10 medical professionals to the system and asked them to re-create 12 images from a CT data set. They evaluated response times and usability of the system compared with standard mouse/keyboard control. Users felt comfortable with the system after approximately 10 minutes. Response time was 120 ms. Users required 1.4 times more time to re-create an image with gesture control. Users with OsiriX experience were significantly faster using the mouse/keyboard and faster than users without prior experience. They rated the system 3.4 out of 5 for ease of use in comparison to the mouse/keyboard. The touch-free, gesture-controlled system performs favorably and removes a potential vector for infection, protecting both patients and staff. Because the camera can be quickly and easily integrated into existing systems, requires no calibration, and is low cost, the barriers to using this technology are low.
引用
收藏
页码:301 / 307
页数:7
相关论文
共 15 条
[1]   Navigation in endoscopic soft tissue surgery: Perspectives and limitations [J].
Baumhauer, Matthias ;
Feuerstein, Marco ;
Meinzer, Hans-Peter ;
Rassweiler, J. .
JOURNAL OF ENDOUROLOGY, 2008, 22 (04) :751-766
[2]  
Dabrowski JR, 2004, P C HUM FACT COMP SY, P317
[3]   Voice Recognition Interfaces (VRI) optimize the utilization of theatre staff and time during laparoscopic cholecystectomy [J].
El-Shallaly, GEH ;
Mohammed, B ;
Muhtaseb, MS ;
Hamouda, AH ;
Nassar, AHM .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2005, 14 (06) :369-371
[4]  
Font-Vizcarra L, 2010, HIP INT, V20, P43
[5]  
Gratzel C, 2004, Technol Health Care, V12, P245
[6]   Computer keyboard and mouse as a reservoir of pathogens in an intensive care unit [J].
Hartmann B. ;
Benson M. ;
Junger A. ;
Quinzio L. ;
Röhrig R. ;
Fengler B. ;
Färber U.W. ;
Wille B. ;
Hempelmann G. .
Journal of Clinical Monitoring and Computing, 2004, 18 (1) :7-12
[7]   Likert scales: how to (ab)use them [J].
Jamieson, S .
MEDICAL EDUCATION, 2004, 38 (12) :1217-1218
[8]  
Korb W, 2006, STUD HEALTH TECHNOL, V119, P267
[9]   The voice-controlled robotic assist scope holder AESOP for the endoscopic approach to the sella [J].
Nathan, Cherie-Ann O. ;
Chakradeo, Vinaya ;
Malhotra, Kavita ;
D'Agostino, Horacio ;
Patwardhan, Ravish .
SKULL BASE-AN INTERDISCIPLINARY APPROACH, 2006, 16 (03) :123-131
[10]  
Renato Archer Center for Information Technology Campinas Brazil, GEST INT US KIN MED