Quantitative assessment of muscle damage in the mdx mouse model of Duchenne muscular dystrophy using polarization-sensitive optical coherence tomography

被引:21
作者
Yang, Xiaojie [1 ]
Chin, Lixin [1 ]
Klyen, Blake R. [1 ]
Shavlakadze, Tea [2 ]
McLaughlin, Robert A. [1 ]
Grounds, Miranda D. [2 ]
Sampson, David D. [1 ,3 ]
机构
[1] Univ Western Australia, Sch Elect Elect & Comp Engn, Opt Biomed Engn Lab, Crawley, WA 6009, Australia
[2] Univ Western Australia, Skeletal Muscle Res Grp, Sch Anat Physiol & Human Biol, Crawley, WA 6009, Australia
[3] Univ Western Australia, Ctr Microscopy Characterisat & Anal, Crawley, WA 6009, Australia
关键词
polarization-sensitive optical coherence tomography; birefringence; muscular dystrophy; mdx mouse; necrosis; SKELETAL-MUSCLE; NEEDLE PROBE; BIREFRINGENCE; FIBER; MICE; EXPRESSION; NECROSIS; VECTOR;
D O I
10.1152/japplphysiol.00265.2013
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Minimally invasive, high-resolution imaging of muscle necrosis has the potential to aid in the assessment of diseases such as Duchenne muscular dystrophy. Undamaged muscle tissue possesses high levels of optical birefringence due to its anisotropic ultrastructure, and this birefringence decreases when the tissue undergoes necrosis. In this study, we present a novel technique to image muscle necrosis using polarization-sensitive optical coherence tomography (PS-OCT). From PS-OCT scans, our technique is able to quantify the birefringence in muscle tissue, generating an image indicative of the tissue ultrastructure, with areas of abnormally low birefringence indicating necrosis. The technique is demonstrated on excised skeletal muscles from exercised dystrophic mdx mice and control C57BL/10ScSn mice with the resulting images validated against colocated histological sections. The technique additionally gives a measure of the proportion (volume fraction) of necrotic tissue within the three-dimensional imaging field of view. The percentage necrosis assessed by this technique is compared against the percentage necrosis obtained from manual assessment of histological sections, and the difference between the two methods is found to be comparable to the interobserver variability of the histological assessment. This is the first published demonstration of PS-OCT to provide automated assessment of muscle necrosis.
引用
收藏
页码:1393 / 1401
页数:9
相关论文
共 55 条
  • [1] Detection of multiple scattering in optical coherence tomography using the spatial distribution of Stokes vectors
    Adie, Steven G.
    Hillman, Timothy R.
    Sampson, David D.
    [J]. OPTICS EXPRESS, 2007, 15 (26): : 18033 - 18049
  • [2] Albumin targeting of damaged muscle fibres in the mdx mouse can be monitored by MRI
    Amthor, H
    Egelhof, T
    McKinnell, I
    Ladd, ME
    Janssen, I
    Weber, J
    Sinn, H
    Schrenk, HH
    Forsting, M
    Voit, T
    Straub, V
    [J]. NEUROMUSCULAR DISORDERS, 2004, 14 (12) : 791 - 796
  • [3] Born M.A. X., 1980, Principles of Optics, P665
  • [4] Diagnosis and management of Duchenne muscular dystrophy, part 1: diagnosis, and pharmacological and psychosocial management
    Bushby, Katharine
    Finkel, Richard
    Birnkrant, David J.
    Case, Laura E.
    Clemens, Paula R.
    Cripe, Linda
    Kaul, Ajay
    Kinnett, Kathi
    McDonald, Craig
    Pandya, Shree
    Poysky, James
    Shapiro, Frederic
    Tomezsko, Jean
    Constantin, Carolyn
    [J]. LANCET NEUROLOGY, 2010, 9 (01) : 77 - 93
  • [5] En face parametric imaging of tissue birefringence using polarization-sensitive optical coherence tomography
    Chin, Lixin
    Yang, Xiaojie
    McLaughlin, Robert A.
    Noble, Peter B.
    Sampson, David D.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (06)
  • [6] INTRINSIC BIREFRIGENCE OF GLYCERINATED MYOFIBRILS
    COLBY, RH
    [J]. JOURNAL OF CELL BIOLOGY, 1971, 51 (03) : 763 - &
  • [7] THE MDX MOUSE SKELETAL-MUSCLE MYOPATHY .1. A HISTOLOGICAL, MORPHOMETRIC AND BIOCHEMICAL INVESTIGATION
    COULTON, GR
    MORGAN, JE
    PARTRIDGE, TA
    SLOPER, JC
    [J]. NEUROPATHOLOGY AND APPLIED NEUROBIOLOGY, 1988, 14 (01) : 53 - 70
  • [8] Ultrasound-Guided Optical Coherence Tomography Needle Probe for the Assessment of Breast Cancer Tumor Margins
    Curatolo, Andrea
    McLaughlin, Robert A.
    Quirk, Bryden C.
    Kirk, Rodney W.
    Bourke, Anita G.
    Wood, Benjamin A.
    Robbins, Peter D.
    Saunders, Christobel M.
    Sampson, David D.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (04) : W520 - W522
  • [9] Review of polarization sensitive optical coherence tomography and Stokes vector determination
    de Boer, JF
    Milner, TE
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (03) : 359 - 371
  • [10] Fercher AF, 2003, REP PROG PHYS, V66, P239, DOI 10.2184/lsj.31.635